Fluorescence technologies have been the preferred method for detection, analytical sensing, medical diagnostics, biotechnology, imaging, and gene expression for many years. Fluorescence becomes essential for studying molecular processes with high specificity and sensitivity through a variety of biological processes. A significant problem for practical fluorescence applications is the apparent non-linearity of the fluorescence intensity resulting from inner-filter effects, sample scattering, and absorption of intrinsic components of biological samples. Sample absorption can lead to the primary inner filter effect (Type I inner filter effect) and is the first factor that should be considered. This is a relatively simple factor to be controlled in any fluorescence experiment. However, many previous approaches have given only approximate experimental methods for correcting the deviation from expected results. In this part we are discussing the origin of the primary inner filter effect and presenting a universal approach for correcting the fluorescence intensity signal in the full absorption range. Importantly, we present direct experimental results of how the correction works. One considers problems emerging from varying absorption across its absorption spectrum for all fluorophores. We use Rhodamine 800 and demonstrate how to properly correct the excitation spectra in a broad wavelength range. Second is the effect of an inert absorber that attenuates the intensity of the excitation beam as it travels through the cuvette, which leads to a significant deviation of observed results. As an example, we are presenting fluorescence quenching of a tryptophan analog, NATA, by acrylamide and we show how properly corrected results compare to the initial erroneous results. The procedure is generic and applies to many other applications like quantum yield determination, tissue/blood absorption, or acceptor absorption in FRET experiments.
24 May 2021 in Methods and Applications in Fluorescence
Fluorescence is an established technology for studying molecular processes and molecular interactions. More recently fluorescence became a leading method for detection, sensing, medical diagnostics, biotechnology, imaging, DNA analysis, and gene expression. Consequently, precise and accurate measurements in various conditions have become more critical for proper result interpretations. Previously, in Part 1, we discussed inner filter effect type I, which is a consequence of the instrumental geometrical sensitivity factor and absorption of the excitation. In this part, we analyze inner filter effect type II and discuss the practical consequences for fluorescence measurements in samples of high optical density (absorbance/scattering). We consider both the standard square and front-face experimental configurations, discuss experimental approaches to limit/mitigate the effect and discuss methods for correcting and interpreting experimental results.
6 August 2022 in Experimental Biology and Medicine
Optical biomedical imaging and diagnostics is a rapidly growing field that provides both structural and functional information with uses ranging from fundamental to practical clinical applications. Nevertheless, imaging/visualizing fluorescence objects with high spatial resolution in a highly scattering and emissive biological medium continues to be a significant challenge. A fundamental limiting factor for imaging technologies is the signal-to-background ratio (SBR). For a long time to improve the SBR, we tried to improve the brightness of fluorescence probes. Many novel fluorophores with improved brightness (almost reaching the theoretical limit), redshifted emission, highly improved photostability, and biocompatibility greatly helped advance fluorescence detection and imaging. However, autofluorescence, scattering of excitation light, and Raman scattering remain fundamental limiting problems that drastically limit detection sensitivity. Similarly, significant efforts were focused on reducing the background. High-quality sample purification eliminates the majority of autofluorescence background and in a limited confocal volume allows detection to reach the ultimate sensitivity to a single molecule. However, detection and imaging in physiological conditions does not allow for any sample (cells or tissue) purification, forcing us to face a fundamental limitation. A significant improvement in limiting background can be achieved when fluorophores with a long fluorescence lifetime are used, and time-gated detection is applied. However, all long-lived fluorophores present low brightness, limiting the potential improvement. We recently proposed to utilize multipulse excitation (burst of pulses) to enhance the relative signal of long-lived fluorophores and significantly improve the SBR. Herein, we present results obtained with multipulse excitation and compare them with standard single-pulse excitation. Subtraction of images obtained with a single pulse from those obtained with pulse burst (differential image) highly limits background and instrumental noise resulting in more specific/sensitive detection and allows to achieve greater imaging depth in highly scattering media, including skin and tissue.
1 January 2020 in Methods and Applications in Fluorescence
We report the spectral properties of 2-Phenylindole (2PI) embedded in rigid poly (vinyl alcohol) (PVA) film. The 2PI in PVA film shows relatively strong and structured fluorescence with a maximum at 370 nm and surprisingly strong room temperature phosphorescence with an emission maximum of about 500 nm. The dye is highly immobilized in the polymer matrix, thus presenting high fluorescence anisotropy in an isotropic film of about 0.3 at room temperature. The 2-Phenylindole phosphorescence excited in the usual way through the electronic singlet state excitation (S 0 → S 1 absorption) results in a very low, near zero anisotropy. We now report that we can directly excite the dye to the triplet state T 1 and observe high phosphorescence anisotropy similar to the fluorescence anisotropy. The extinction coefficient for S 0 → T 1 absorption in the PVA matrix is unusually high- only about 3 orders of magnitude lower than S 0 → S 1 absorption. We consider this direct excitation to indole’s triplet state a very significant finding that may lead to many practical applications. The unusually long-wavelength of excitation around 400 nm, much above typical UV absorption, results in a high phosphorescence anisotropy. This provides a new way to study rotational motion of larger biological objects in the microsecond time scale not accessible through typical fluorescence studies.
2 February 2022 in Methods and Applications in Fluorescence
We studied room temperature phosphorescence of tryptophan (TRP) embedded in poly (vinyl alcohol) films. With UV (285 nm) excitation, the phosphorescence spectrum of tryptophan appears at about 460 nm. We also observed the TRP phosphorescence with blue light excitation at 410 nm, well outside of the S 0 →S 1 absorption. This excitation reaches the triplet state of tryptophan directly without the involvement of the singlet excited state. The phosphorescence lifetime of tryptophan is in the sub-millisecond range. The long-wavelength direct excitation to the triplet state results in high phosphorescence anisotropy which can be useful in macromolecule dynamics study via time-resolved phosphorescence.
Cytotoxic activity has been reported for the xanthone α-mangostin (AMN) against Glioblastoma multiforme (GBM), an aggressive malignant brain cancer with a poor prognosis. Recognizing that AMN’s high degree of hydrophobicity is likely to limit its systemic administration, we formulated AMN using reconstituted high-density lipoprotein (rHDL) nanoparticles. The photophysical characteristics of the formulation, including fluorescence lifetime and steady-state anisotropy, indicated that AMN was successfully incorporated into the rHDL nanoparticles. To our knowledge, this is the first report on the fluorescent characteristics of AMN with an HDL-based drug carrier. Cytotoxicity studies in a 2D culture and 3D spheroid model of LN-229 GBM cells and normal human astrocytes showed an enhanced therapeutic index with the rHDL-AMN formulation compared to the unincorporated AMN and Temozolomide, a standard GBM chemotherapy agent. Furthermore, treatment with the rHDL-AMN facilitated a dose-dependent upregulation of autophagy and reactive oxygen species generation to a greater extent in LN-229 cells compared to astrocytes, indicating the reduced off-target toxicity of this novel formulation. These studies indicate the potential therapeutic benefits to GBM patients via selective targeting using the rHDL-AMN formulation.