Jianfeng He

Dr. Jianfeng He


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2024 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
XXXin Xiong
Xin Xiong
AWAikun Wang
Aikun Wang
JHJianfeng He
Jianfeng He
CWChunwu Wang
Chunwu Wang
RLRuixiang Liu
Ruixiang Liu
JZJing Zhang
Jing Zhang
Introduction: Sleep apnoea syndrome (SAS) is a serious sleep disorder and early detection of sleep apnoea not only reduces treatment costs but also saves lives. Conventional polysomnography (PSG) is widely regarded as the gold standard diagnostic tool for sleep apnoea. However, this method is expensive, time-consuming and inherently disruptive to sleep. Recent studies have pointed out that ECG analysis is a simple and effective diagnostic method for sleep apnea, which can effectively provide physicians with an aid to diagnosis and reduce patients’ suffering.Methods: To this end, in this paper proposes a LightGBM hybrid model based on ECG signals for efficient detection of sleep apnea. Firstly, the improved Isolated Forest algorithm is introduced to remove abnormal data and solve the data sample imbalance problem. Secondly, the parameters of LightGBM algorithm are optimised by the improved TPE (Tree-structured Parzen Estimator) algorithm to determine the best parameter configuration of the model. Finally, the fusion model TPE_OptGBM is used to detect sleep apnoea. In the experimental phase, we validated the model based on the sleep apnoea ECG database provided by Phillips-University of Marburg, Germany.Results: The experimental results show that the model proposed in this paper achieves an accuracy of 95.08%, a precision of 94.80%, a recall of 97.51%, and an F1 value of 96.14%.Discussion: All of these evaluation indicators are better than the current mainstream models, which is expected to assist the doctor’s diagnostic process and provide a better medical experience for patients.

25 August 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XXXin Xiong
Xin Xiong
YRYuyan Ren
Yuyan Ren
SGShenghan Gao
Shenghan Gao
JLJianhua Luo
Jianhua Luo
JLJiangli Liao
Jiangli Liao
JHJianfeng He
Jianfeng He
Obstructive sleep apnea (OSA) is a common sleep respiratory disease. Previous studies have found that the wakefulness electroencephalogram (EEG) of OSA patients has changed, such as increased EEG power. However, whether the microstates reflecting the transient state of the brain is abnormal is unclear during obstructive hypopnea (OH). We investigated the microstates of sleep EEG in 100 OSA patients. Then correlation analysis was carried out between microstate parameters and EEG markers of sleep disturbance, such as power spectrum, sample entropy and detrended fluctuation analysis (DFA). OSA_OH patients showed that the microstate C increased presence and the microstate D decreased presence compared to OSA_withoutOH patients and controls. The fifth microstate E appeared during N1-OH, but the probability of other microstates transferring to microstate E was small. According to the correlation analysis, OSA_OH patients in N1-OH showed that the microstate D was positively correlated with delta power, and negatively correlated with beta and alpha power; the transition probability of the microstate B → C and E → C was positively correlated with alpha power. In other sleep stages, the microstate parameters were not correlated with power, sample entropy and FDA. We might interpret that the abnormal transition of brain active areas of OSA patients in N1-OH stage leads to abnormal microstates, which might be related to the change of alpha activity in the cortex.

2 June 2021 in Japanese Journal of Radiology
Verified
Journal Article
Closed access
PDF file
SWShaobo Wang
Shaobo Wang
BLBoqiao Li
Boqiao Li
PLPengfei Li
Pengfei Li
RXRan Xie
Ran Xie
QWQuanshi Wang
Quanshi Wang
JHJianfeng He
Jianfeng He

7 March 2024 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
TTTingting Tao
Tingting Tao
YCYing Chen
Ying Chen
YSYunyun Shang
Yunyun Shang
JHJianfeng He
Jianfeng He
JHJingang Hao
Jingang Hao
Background: Multi-parametric magnetic resonance imaging (MP-MRI) may provide comprehensive information for graded diagnosis of bladder cancer (BCa). Nevertheless, existing methods ignore the complex correlation between these MRI sequences, failing to provide adequate information. Therefore, the main objective of this study is to enhance feature fusion and extract comprehensive features from MP-MRI using deep learning methods to achieve an accurate diagnosis of BCa grading.Methods: In this study, a self-attention-based MP-MRI feature fusion framework (SMMF) is proposed to enhance the performance of the model by extracting and fusing features of both T2-weighted imaging (T2WI) and dynamic contrast-enhanced imaging (DCE) sequences. A new multiscale attention (MA) model is designed to embed into the neural network (CNN) end to further extract rich features from T2WI and DCE. Finally, a self-attention feature fusion strategy (SAFF) was used to effectively capture and fuse the common and complementary features of patients’ MP-MRIs.Results: In a clinically collected sample of 138 BCa patients, the SMMF network demonstrated superior performance compared to the existing deep learning-based bladder cancer grading model, with accuracy, F1 value, and AUC values of 0.9488, 0.9426, and 0.9459, respectively.Conclusion: Our proposed SMMF framework combined with MP-MRI information can accurately predict the pathological grading of BCa and can better assist physicians in diagnosing BCa.

24 May 2023 in Frontiers in Neuroscience
Verified
Journal Article
Open access
XXXin Xiong
Xin Xiong
JFJiannan Feng
Jiannan Feng
YZYaru Zhang
Yaru Zhang
DWDi Wu
Di Wu
SYSanli Yi
Sanli Yi
JHJianfeng He
Jianfeng He
Background: Substance addiction is a chronic disease which causes great harm to modern society and individuals. At present, many studies have applied EEG analysis methods to the substance addiction detection and treatment. As a tool to describe the spatio-temporal dynamic characteristics of large-scale electrophysiological data, EEG microstate analysis has been widely used, which is an effective method to study the relationship between EEG electrodynamics and cognition or disease.Methods: To study the difference of EEG microstate parameters of nicotine addicts at each frequency band, we combine an improved Hilbert Huang Transformation (HHT) decomposition with microstate analysis, which is applied to the EEG of nicotine addicts.Results: After using improved HHT-Microstate method, we notice that there is significant difference in EEG microstates of nicotine addicts between viewing smoke pictures group (smoke) and viewing neutral pictures group (neutral). Firstly, there is a significant difference in EEG microstates at full-frequency band between smoke and neutral group. Compared with the FIR-Microstate method, the similarity index of microstate topographic maps at alpha and beta bands had significant differences between smoke and neutral group. Secondly, we find significant class × group interactions for microstate parameters at delta, alpha and beta bands. Finally, the microstate parameters at delta, alpha and beta bands obtained by the improved HHT-microstate analysis method are selected as features for classification and detection under the Gaussian kernel support vector machine. The highest accuracy is 92% sensitivity is 94% and specificity is 91%, which can more effectively detect and identify addiction diseases than FIR-Microstate and FIR-Riemann methods.Conclusion: Thus, the improved HHT-Microstate analysis method can effectively identify substance addiction diseases and provide new ideas and insights for the brain research of nicotine addiction.

22 February 2024 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
TWTao Wang
Tao Wang
YDYinglei Deng
Yinglei Deng
SWSidan Wang
Sidan Wang
JHJianfeng He
Jianfeng He
SWShaobo Wang
Shaobo Wang
Background: The endoplasmic reticulum plays an important role in glucose metabolism and has not been explored in the kinetic estimation of hepatocellular carcinoma (HCC) via 18F-fluoro-2-deoxy-d-glucose PET/CT. Methods: A dual-input four-compartment (4C) model, regarding endoplasmic reticulum was preliminarily used for kinetic estimation to differentiate 28 tumours from background liver tissue from 24 patients with HCC. Moreover, parameter images of the 4C model were generated from one patient with negative findings on conventional metabolic PET/CT. Results: Compared to the dual-input three-compartment (3C) model, the 4C model has better fitting quality, a close transport rate constant (K1) and a dephosphorylation rate constant (k6/k4), and a different removal rate constant (k2) and phosphorylation rate constant (k3) in HCC and background liver tissue. The K1, k2, k3, and hepatic arterial perfusion index (HPI) from the 4C model and k3, HPI, and volume fraction of blood (Vb) from the 3C model were significantly different between HCC and background liver tissues (all P < 0.05). Meanwhile, the 4C model yielded additional kinetic parameters for differentiating HCC. The diagnostic performance of the top ten genes from the most to least common was HPI(4C), Vb(3C), HPI(3C), SUVmax, k5(4C), k3(3C), k2(4C), v(4C), K1(4C) and Vb(4C). Moreover, a patient who showed negative findings on conventional metabolic PET/CT had positive parameter images in the 4C model. Conclusions: The 4C model with the endoplasmic reticulum performed better than the 3C model and produced additional useful parameters in kinetic estimation for differentiating HCC from background liver tissue.