Abhinav Bhushan

Prof. Abhinav Bhushan

Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2022 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
MHMuhammad R. Haque
Muhammad R. Haque
CWCaitlin R. Wessel
Caitlin R. Wessel
DLDaniel D. Leary
Daniel D. Leary
CWChengyao Wang
Chengyao Wang
Abhinav BhushanAbhinav Bhushan
Abhinav Bhushan
FBFaraz Bishehsari
Faraz Bishehsari
The patient population suffering from pancreatic ductal adenocarcinoma (PDAC) presents, as a whole, with a high degree of molecular tumor heterogeneity. The heterogeneity of PDAC tumor composition has complicated treatment and stalled success in clinical trials. Current in vitro techniques insufficiently replicate the intricate stromal components of PDAC tumor microenvironments (TMEs) and fail to model a given tumor’s unique genetic phenotype. The development of patient-derived organoids (PDOs) has opened the door for improved personalized medicine since PDOs are derived directly from patient tumors, thus preserving the tumors’ unique behaviors and genetic phenotypes. This study developed a tumor-chip device engineered to mimic the PDAC TME by incorporating PDOs and stromal cells, specifically pancreatic stellate cells and macrophages. Establishing PDOs in a multicellular microfluidic chip device prolongs cellular function and longevity and successfully establishes a complex organotypic tumor environment that incorporates desmoplastic stroma and immune cells. When primary cancer cells in monoculture were subjected to stroma-depleting agents, there was no effect on cancer cell viability. However, targeting stroma in our tumor-chip model resulted in a significant increase in the chemotherapy effect on cancer cells, thus validating the use of this tumor-chip device for drug testing.

24 April 2014 in Experimental Biology and Medicine
Verified
Journal Article
Open access
PDF file
SBShyam Sundhar Bale
Shyam Sundhar Bale
LVLawrence Vernetti
Lawrence Vernetti
NSNina Senutovitch
Nina Senutovitch
RJRohit Jindal
Rohit Jindal
MHManjunath Hegde
Manjunath Hegde
MYMartin L Yarmush
Martin L Yarmush
The liver is a heterogeneous organ with many vital functions, including metabolism of pharmaceutical drugs and is highly susceptible to injury from these substances. The etiology of drug-induced liver disease is still debated although generally regarded as a continuum between an activated immune response and hepatocyte metabolic dysfunction, most often resulting from an intermediate reactive metabolite. This debate stems from the fact that current animal and in vitro models provide limited physiologically relevant information, and their shortcomings have resulted in “silent” hepatotoxic drugs being introduced into clinical trials, garnering huge financial losses for drug companies through withdrawals and late stage clinical failures. As we advance our understanding into the molecular processes leading to liver injury, it is increasingly clear that (a) the pathologic lesion is not only due to liver parenchyma but is also due to the interactions between the hepatocytes and the resident liver immune cells, stellate cells, and endothelial cells; and (b) animal models do not reflect the human cell interactions. Therefore, a predictive human, in vitro model must address the interactions between the major human liver cell types and measure key determinants of injury such as the dosage and metabolism of the drug, the stress response, cholestatic effect, and the immune and fibrotic response. In this mini-review, we first discuss the current state of macro-scale in vitro liver culture systems with examples that have been commercialized. We then introduce the paradigm of microfluidic culture systems that aim to mimic the liver with physiologically relevant dimensions, cellular structure, perfusion, and mass transport by taking advantage of micro and nanofabrication technologies. We review the most prominent liver-on-a-chip platforms in terms of their physiological relevance and drug response. We conclude with a commentary on other critical advances such as the deployment of fluorescence-based biosensors to identify relevant toxicity pathways, as well as computational models to create a predictive tool.

29 October 2014 in Tissue Engineering Part C: Methods
Verified
Journal Article
Closed access
SBShyam Sundhar Bale
Shyam Sundhar Bale
IGInna Golberg
Inna Golberg
RJRohit Jindal
Rohit Jindal
WMWilliam J. McCarty
William J. McCarty
MLMartha Luitje
Martha Luitje
MYMartin L. Yarmush
Martin L. Yarmush
Hepatocytes and their in vitro models are essential tools for preclinical screening studies for drugs that affect the liver. Most of the current models primarily focus on hepatocytes alone and lack the contribution of non-parenchymal cells (NPCs), which are significant through both molecular and the response of the NPCs themselves. Models that incorporate NPCs alongside hepatocytes hold the power to enable more realistic recapitulation and elucidation of cell interactions and cumulative drug response. Hepatocytes and liver sinusoidal endothelial cells (LSECs) account for ∼80% of the liver mass where the LSECs line the walls of blood vessels, and act as a barrier between hepatocytes and blood. Culturing LSECs with hepatocytes to generate multicellular physiologically relevant in vitro liver models has been a major hurdle since LSECs lose their phenotype rapidly after isolation. To this end, we describe the application of collagen gel (1) in a sandwich and (2) as an intervening extracellular matrix layer to coculture hepatocytes with LSECs for extended periods. These coculture configurations provide environments wherein hepatocyte and LSECs, through cell–cell contacts and/or secretion factors, lead to enhanced function and stability of the cocultures. Our results show that in these configurations, hepatocytes and LSECs maintained their phenotypes when cultured together as a mixture, and showed stable secretion and metabolic activity for up to 4 weeks. Immunostaining for sinusoidal endothelial 1 (SE-1) antibody demonstrated retention of LSEC phenotype during the culture period. In addition, LSECs cultured alone maintained high viability and SE-1 expression when cultured within a collagen sandwich configuration up to 4 weeks. Albumin production of the cocultures was 10–15 times higher when LSECs were cultured as a bottom layer (with an intervening collagen layer) and as a mixture in a sandwich configuration, and native CYP 1A1/2 activity was at least 20 times higher than monoculture controls. Together, these data suggest that collagen gel-based hepatocyte-LSEC cocultures are highly suitable models for stabilization and long-term culture of both cell types. In summary, these results indicate that collagen gel-based hepatocyte-LSEC coculture models are promising for in vitro toxicity testing, and liver model development studies.

24 March 2014 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MHManjunath Hegde
Manjunath Hegde
RJRohit Jindal
Rohit Jindal
Abhinav BhushanAbhinav Bhushan
Abhinav Bhushan
SBShyam Sundhar Bale
Shyam Sundhar Bale
WMWilliam J McCarty
William J McCarty
MYMartin L. Yarmush
Martin L. Yarmush
A two chambered device that enables sandwich culture of primary hepatocytes in conjunction with flow on top of the gel. Increased collagen secretion under flow leads to stabilization and enhancement of hepatocytes function

10 October 2022 in Microorganisms
Verified
Journal Article
Open access
PDF file
CFChristopher B. Forsyth
Christopher B. Forsyth
LZLijuan Zhang
Lijuan Zhang
Abhinav BhushanAbhinav Bhushan
Abhinav Bhushan
BSBarbara Swanson
Barbara Swanson
LZLi Zhang
Li Zhang
AKAli Keshavarzian
Ali Keshavarzian
The coronavirus disease 2019 (COVID-19) pandemic began in January 2020 in Wuhan, China, with a new coronavirus designated SARS-CoV-2. The principal cause of death from COVID-19 disease quickly emerged as acute respiratory distress syndrome (ARDS). A key ARDS pathogenic mechanism is the “Cytokine Storm”, which is a dramatic increase in inflammatory cytokines in the blood. In the last two years of the pandemic, a new pathology has emerged in some COVID-19 survivors, in which a variety of long-term symptoms occur, a condition called post-acute sequelae of COVID-19 (PASC) or “Long COVID”. Therefore, there is an urgent need to better understand the mechanisms of the virus. The spike protein on the surface of the virus is composed of joined S1–S2 subunits. Upon S1 binding to the ACE2 receptor on human cells, the S1 subunit is cleaved and the S2 subunit mediates the entry of the virus. The S1 protein is then released into the blood, which might be one of the pivotal triggers for the initiation and/or perpetuation of the cytokine storm. In this study, we tested the hypothesis that the S1 spike protein is sufficient to activate inflammatory signaling and cytokine production, independent of the virus. Our data support a possible role for the S1 spike protein in the activation of inflammatory signaling and cytokine production in human lung and intestinal epithelial cells in culture. These data support a potential role for the SARS-CoV-2 S1 spike protein in COVID-19 pathogenesis and PASC.

20 June 2006 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
Abhinav BhushanAbhinav Bhushan
Abhinav Bhushan
DYDawit Yemane
Dawit Yemane
DTDan Trudell
Dan Trudell
EOEdward B. Overton
Edward B. Overton
JGJost Goettert
Jost Goettert