Vahid Broujerdian

Dr. Vahid Broujerdian

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Structures
Verified
Journal Article
Closed access
VBVahid Broujerdian
Vahid Broujerdian
Ali GhamariAli Ghamari
Ali Ghamari
AAAlireza Abbaszadeh
Alireza Abbaszadeh

28 January 2022 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
VBVahid Broujerdian
Vahid Broujerdian
EDEsmaeil Mohammadi Dehcheshmeh
Esmaeil Mohammadi Dehcheshmeh
1


22 September 2023 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
AAAlireza Abbaszadeh
Alireza Abbaszadeh
Ali GhamariAli Ghamari
Ali Ghamari
VBVahid Broujerdian
Vahid Broujerdian
The steel shear wall has been introduced as a system with high stiffness and strength and a considerable capability in absorbing seismic energy. Due to its special advantages compared to other lateral load-resistant systems, this system is being used in tall buildings more and more frequently. Ductility and energy absorption are important parameters to be considered when choosing a robust lateral load-resistant system. By increasing the ductility and energy absorption of the structures, their seismic performance and safety are improved. Ideally, a structural system should provide both ductility and energy absorption in an economic way. This study presents the numerical simulation of the seismic behavior of a recently developed four-layer steel shear wall composed of corrugated and flat sheets. The simulations were performed using finite element software ABAQUS. Nonlinear static analysis was used to derive seismic parameters. The results showed that the corrugated sheets surrounded by flat sheets provide greater seismic parameters such as ductility and over-strength compared to double corrugated walls. According to the results, the calculated R-factor, displacement amplification factor, and the overstrength factor of the proposed wall were 4.58, 8.21, and 1.26, respectively. Furthermore, to use the seismic parameters of the shear wall, some relationships have been presented for incremental strength and stiffness coefficients without the need for finite element modeling. Compared to the finite element results, the presented relations had good accuracy.

11 December 2018 in Advances in Structural Engineering
Verified
Journal Article
Closed access
AGAbbas Ghadami
Abbas Ghadami
VBVahid Broujerdian
Vahid Broujerdian
In literature, there is no theoretical research focusing on moment–shear interaction behavior of the hybrid girders. This article investigates the moment–shear interaction behavior of non-composite hybrid steel plate I-girders at ambient and elevated temperatures. In this regard, based on a more realistic distribution of bending and shear stresses, theoretical equations have been proposed to achieve the moment–shear interaction curve without considering shear buckling. The results obtained from the proposed equations were compared with the results of the existing experimental data and those of the finite element analysis. According to the results, there is good agreement between them.

1 September 2015 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
VBVahid Broujerdian
Vahid Broujerdian
PMP. Mahyar
P. Mahyar
AGAbbas Ghadami
Abbas Ghadami