shuang qu

Dr. shuang qu

Shandong Jianzhu University
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Structures
Verified
Journal Article
Closed access
BZBingjie Zhang
Bingjie Zhang
YWYuzhuo Wang
Yuzhuo Wang
GLGuoqiang Li
Guoqiang Li
SQshuang qu
shuang qu
CFChuanguo Fu
Chuanguo Fu
TXTiangui Xu
Tiangui Xu

8 April 2021 in Processes
Verified
Journal Article
Open access
PDF file
YLYan Lin
Yan Lin
CZChongting Zhong
Chongting Zhong
JSJiankai Song
Jiankai Song
SQshuang qu
shuang qu
Different to conventional reinforced concrete or steel material, a new type of concrete-filled steel box slab has been proposed by effectively integrating the combined benefits of both steel and concrete. By filling concrete, this type of slab could avoid the local bucking of steel plate and then could provide a high moment capacity. Therefore, this study aims to investigate the flexural behavior of concrete-filled steel box slabs through testing seven specimens and characterize their failure characteristics, stress distribution and ultimate moment capacity. A comprehensive parametric study focuses on the influence of the steel plate thickness, the stud and stiffening plate on the slab flexural behavior. The results show that concrete-filled steel box slabs had a high moment capacity and good ductility. The thickness of the steel plate had a significant influence on the moment capacity of the specimen. The stud led to the reduction of the moment capacity of the slab. The stiffening plate effectively improved the flexural behavior of the specimen. Moreover, a calculation method was formulated to describe the moment capacity of the slab and compared with experimental results. The results show that the proposed method for the moment capacity of the slab was conservative and reasonable.

14 February 2023 in Buildings
Verified
Journal Article
Open access
PDF file
YLYan Lin
Yan Lin
ZZZhijie Zhao
Zhijie Zhao
XGXuhui Gao
Xuhui Gao
ZWZhen Wang
Zhen Wang
SQshuang qu
shuang qu
Two new types of connection between concrete-filled U-shaped steel (CFUS) beams and concrete-filled square steel tube (CFSST) columns were presented in this study, including rebar-sleeve with internal diaphragm connection and rebar-through with internal diaphragm connection. Based on the experiments of the rebar-plate with internal diaphragm connections between CFUS beams and CFSST columns under cyclic loading, the nonlinear finite element models of the tested specimens were developed and validated by comparing them with the experimental results. The numerical results were in agreement with the experimental results in terms of failure modes, stress distribution, and load-displacement skeleton curves. Based on the FEA results, the mechanical behavior of the two new types of connection were comprehensively discussed and compared. Furthermore, this parametric study was conducted for the rebar-sleeve with internal diaphragm connection to investigate the effect of specific parameters on the capacity of the connection. The parameters included: The thickness of U-shaped steel, the ratio of longitudinal reinforcement in the concrete slab, the strength of concrete in the beam, the strength of the U-shaped steel, and the thickness of the internal diaphragm. The results indicate that the thickness of the U-shaped steel (tb), the ratio of the longitudinal reinforcement in concrete slab (ρ), and the strength of the U-shaped steel have significant effects on the loading capacity of the connection—the loading capacity increases by about 20% when tb increases from 6 mm to 8 mm, increases by about 45% when ρ increases from 1.5% to 4.8% under negative P, and increases by about 20% when the steel yield strength (fy) increases from 235 Mpa to 420 Mpa.

3 January 2023 in Case Studies in Construction Materials
Verified
Journal Article
Open access
YWYuzhuo Wang
Yuzhuo Wang
CLChen Liang
Chen Liang
BZBingjie Zhang
Bingjie Zhang
SQshuang qu
shuang qu
YGYing Gao
Ying Gao
XZXiao Zhang
Xiao Zhang

1 August 2013 in Applied Mechanics and Materials
Verified
Journal Article
Closed access
PDF file
CLChun Yang Liu
Chun Yang Liu
ZLZhen Bao Li
Zhen Bao Li
SQshuang qu
shuang qu
XZXue Jun Zhou
Xue Jun Zhou
XWXin Ping Wang
Xin Ping Wang
Lots of bulidings had collapsed in Wenchuan big earthquake in 2008, one important reason is that the structure design has been launched only in X or Y axis of the building respectively, which means the oblique direction compression-bending characteristic has not been fully considered in the actual structure design process. In addition, the moment bearing strength in oblique direction is smaller than the moment strength about the principle axis of the column, so the research on bending strength calculation of biaxial/oblique compression-bending RC column is important to improve the aseismic safty of the buildings under actual earthquake effects. In this paper research achievements about bearing capacity calculation of column under oblique compression-bending action are summarized and analyzed. At last the advice for actual application has also been given.

1 January 2015
Verified
Conference Paper
Open access
PDF file
XLXiaoyang Liu
Xiaoyang Liu
SQshuang qu
shuang qu
In this paper, there are two objectives in the optimisation of thin-walled structure, one of these is to reduce the total mass of the structure, and the other is to ensure the carrying capacity of the structure. The secondary objective, i.e. carrying capacity, is transformed into the optimisation constraints by Constraining Method. The structure is optimized by modifying the thickness of the plate. The finite model is created using ABAQUS/CAE in the visual environment. Then the maximum carrying capacity is calculated by buckling analysis, and used as the applied load in the static analysis. The optimisation software is written by VC ++, which can automatic read the output of ABAQUS data file and use the maximum stress in each plate as a critical stress to calculate the corresponding thickness. Then a new ABAQUS input file with the new plate thicknesses is created by the software. The structure described in the example of this paper finally obtained a minimum mass with great carrying capacity, after six times of optimisation