Robert Zabłotni

Mr. Robert Zabłotni

Lublin University of Technology
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
Rafal RusinekRafal Rusinek
Rafal Rusinek
MSMarcin Szymański
Marcin Szymański
RZRobert Zabłotni
Robert Zabłotni
The middle ear is one of the smallest biomechanical systems in the human body and is responsible for the hearing process. Hearing is modelled in different ways and by various methods. In this paper, three-degree-of-freedom models of the human middle ear with different viscoelastic properties are proposed. Model 1 uses the Maxwell type viscoelasticity, Model 2 is based on the Kelvin–Voigt viscoelasticity, and Model 3 uses the Kelvin–Voigt viscoelasticity with relaxation effect. The primary aim of the study is to compare the models and their dynamic responses to a voice excitation. The novelty of this study lies in using different models of viscoelasticity and relaxation effect that has been previously unstudied. First, mathematical models of the middle ear were built, then they were solved numerically by the Runge–Kutta procedure and finally, numerical results were compared with those obtained from experiments carried out on the temporal bone with the Laser Doppler Vibrometer. The models exhibit differences in the natural frequency and amplitudes near the second resonance. All analysed models can be used for modelling the rapidly changing processes that occur in the ear and to control active middle ear implants.

7 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
Rafal RusinekRafal Rusinek
Rafal Rusinek
JRJoanna Rekas
Joanna Rekas
KWKatarzyna Wojtowicz
Katarzyna Wojtowicz
RZRobert Zabłotni
Robert Zabłotni
This paper presents a possibility of quasi-periodic and chaotic vibrations in the human middle ear stimulated by an implant, which is fixed to the incus by means of a nonlinear coupler. The coupler represents a classical element made of titanium and shape memory alloy. A five-degrees-of-freedom model of lumped masses is used to represent the implanted middle ear for both normal and pathological ears. The model is engaged to numerically find the influence of the nonlinear coupler on stapes and implant dynamics. As a result, regions of parameters regarding the quasi-periodic, polyharmonic and irregular motion are identified as new contributions in ear bio-mechanics. The nonlinear coupler causes irregular motion, which is undesired for the middle ear. However, the use of the stiff coupler also ensures regular vibrations of the stapes for higher frequencies. As a consequence, the utility of the nonlinear coupler is proven.

31 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RZRobert Zabłotni
Robert Zabłotni
STSylwester Tudruj
Sylwester Tudruj
JLJarosław Latalski
Jarosław Latalski
MSMarcin Szymański
Marcin Szymański
AKAndrzej Kucharski
Andrzej Kucharski
Rafal RusinekRafal Rusinek
Rafal Rusinek
This study investigates the dynamic properties of the human middle ear and the energy transfer phenomena between the stapes footplate (SF) and the round window membrane (RWM) under sound stimulation. A series of laboratory tests were conducted, and a numerical model of the system was prepared. During the experiments, vibrations in human temporal bones were recorded using a Laser Doppler Vibrometer (LDV), and the frequency response functions (FRFs) of the RWM and SF footplate were computed. Key resonances were identified, with notable differences in vibration amplitude depending on whether the artificial external ear canal was left open or closed. To evaluate the amplification of acoustic waves within the cochlea, the authors proposed a novel index defined as the ratio of the FRF of the RWM and SF, respectively. The performed computations showed that signal amplification is particularly noticeable in the frequency range from 1 to 2 kHz. Subsequently, a simplified computational fluid dynamics (CFD) model of the cochlea was developed to simulate internal pressure distribution within the scala vestibuli (SV) and scala tympani (ST) spaces. The numerical computations of acoustic signal amplification showed good agreement with the experimental data, particularly at the frequencies of 1 and 2 kHz. These findings provide new insights into cochlear acoustics and offer a potential tool for evaluating pathological disorders and designing prosthetic devices.

23 November 2024 in Materials
Verified
Journal Article
Open access
PDF file
RZRobert Zabłotni
Robert Zabłotni
GZGrzegorz Zajac
Grzegorz Zajac
Rafal RusinekRafal Rusinek
Rafal Rusinek
This study delves into the intricate mechanics of human middle ear implants by examining a lumped parameter model with five degrees of freedom to estimate sound transfer. The ASTM standard, recognized globally as a benchmark, served as a reference for analysis, ensuring test accuracy and providing a comprehensive evaluation framework. To assess the implant’s usability, numerical simulations were conducted and compared against both the ASTM standard and the experimental results obtained from temporal bone studies. This investigation uncovered the bistability of periodic responses induced by the implant, prompting an analysis of the bistability in periodic solutions and the creation of basins of attraction for various initial conditions. The discovery of new solutions underscores this study’s significance in the operation and reliability of implants. Consequently, this research not only enhances the theoretical comprehension of the system, but also holds promise for practical applications in the design and optimization of middle ear implants that transfer energy to the stapes and the cochlea.

17 October 2024 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
RZRobert Zabłotni
Robert Zabłotni
WDWeronika Dabrowa
Weronika Dabrowa
ZSZofia Szmit
Zofia Szmit
Rafal RusinekRafal Rusinek
Rafal Rusinek
In cases of significant hearing loss affecting the auditory ossicles, it is possible to attach an implant. In such cases, the implant is responsible for the movement of the stapes. However, the eardrum is not removed, it remains in the system, forcing movement of the first auditory ossicle –...

19 April 2023
Verified
Conference Paper
Closed access
RZRobert Zabłotni
Robert Zabłotni
RRRafał Rusinek
Rafał Rusinek