Johan Bundgaard

Mr. Johan Bundgaard


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Annals of Internal Medicine
Verified
Journal Article
Open access
HBHenning Bundgaard
Henning Bundgaard
JBJohan Bundgaard
Johan Bundgaard
DRDaniel Emil Tadeusz Raaschou-Pedersen
Daniel Emil Tadeusz Raaschou-Pedersen
Christian von BuchwaldChristian von Buchwald
Christian von Buchwald
Tobias TodsenTobias Todsen
Tobias Todsen
KIKasper Iversen
Kasper Iversen
Observational evidence suggests that mask wearing mitigates SARS-CoV-2 transmission. It is uncertain if this observed association arises through protection of uninfected wearers (protective effect)... Visual Effectiveness of Mask Recommendation for Preventing SARS-CoV-2 Infection Observational evidence suggests that mask wearing mitigates SARS-CoV-2 transmission. It is uncertain if this... Background: Observational evidence suggests that mask wearing mitigates transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). It is uncertain if this observed association ar...

1 March 2019 in International Journal of Cardiology
Verified
Journal Article
Closed access
LØLauge Østergaard
Lauge Østergaard
UMUlrik M. Mogensen
Ulrik M. Mogensen
JBJohan Bundgaard
Johan Bundgaard
ADAnders Dahl
Anders Dahl
AWAndrew Wang
Andrew Wang
EFEmil Loldrup Fosbøl
Emil Loldrup Fosbøl

1 September 2020 in European Heart Journal: Acute Cardiovascular Care
Verified
Journal Article
Open access
PDF file
JBJohan Bundgaard
Johan Bundgaard
PJPeter K Jacobsen
Peter K Jacobsen
JGJohannes Grand
Johannes Grand
MLMatias G Lindholm
Matias G Lindholm
CHChristian Hassager
Christian Hassager
HBHenning Bundgaard
Henning Bundgaard
Background: Electrical storm and incessant ventricular tachycardia (VT) are characterized by the clustering of episodes of VT or ventricular fibrillation (VF) and are associated with a poor prognosis. Autonomic nervous system activity influences VT threshold, and deep sedation may be useful for the treatment of VT emergencies.Methods: We reviewed data from conscious patients admitted to our intensive care unit (ICU) due to monomorphic VT, polymorphic VT or VF at our tertiary center between 2010 and 2018.Results: A total of 46 conscious patients with recurrent ventricular arrhythmia, refractory to initial treatment, were referred to the ICU. The majority (n = 31) were stabilized on usual care. The remaining treatment-refractory 15 patients (57 years (range 9–74), 80% males, seven with implantable cardioverter-defibrillators) with VT/VF storm (n = 11) or incessant VT (n = 4) due to ischemic heart disease (n = 10), cardiomyopathy (n = 2), primary arrhythmia (n = 2) and one patient post valve surgery, were deeply sedated and intubated. A complete resolution of VT/VF within minutes to hours was achieved in 12 patients (80%), partial resolution in two (13%) and one (7%) patient died due to ventricular free-wall rupture. One patient with recurrent VT episodes needing repeated deep sedation developed necrotic caecum. No other major complications were seen. Thirteen (87%) patients were alive after a mean follow-up of 3.7 years.Conclusion: Deep sedation was effective and safe for the temporary management of malignant VT/VF refractory to usual treatment. In emergencies, deep sedation may be widely accessible at both secondary and tertiary centers and a clinically useful bridge to definitive treatment of VT.

9 September 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
JTJohan Hindkjær Therchilsen
Johan Hindkjær Therchilsen
Christian von BuchwaldChristian von Buchwald
Christian von Buchwald
AKAnders Koch
Anders Koch
SNSusanne Dam Nielsen
Susanne Dam Nielsen
DRDaniel Bräuner Rasmussen
Daniel Bräuner Rasmussen
Tobias TodsenTobias Todsen
Tobias Todsen
The aim of this study was to compare the sensitivity of self-collected versus healthcare worker (HCW)-collected swabs for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) testing. Symptomatic individuals referred for SARS-CoV-2 testing were invited to provide mobile-phone video-instructed self-collected oropharyngeal and nasal samples followed by a HCW-collected oropharyngeal sample. All samples were sent for analysis to the same microbiology laboratory, and the number of SARS-CoV-2-positive participants in the two tests was compared. A total of 109 participants were included, and 19 participants had SARS-CoV-2-positive results. The diagnostic sensitivity of the self-collected and HCW-collected swabs was 84.2% and 89.5%, respectively, with an acceptable agreement, Cohens kappa 0.82, p < 0.001. Further, results from a questionnaire answered by the participants found that loss of smell as a self-reported symptom was a strong predictor for a SARS-CoV-2-positive test. In conclusion, we found that self-collected oropharyngeal and nasal swabs for SARS-CoV-2 testing can be reliable compared to HCW-collected oropharyngeal samples.

29 July 2019 in European Journal of Heart Failure
Verified
Journal Article
Open access
PDF file
JBJohan Bundgaard
Johan Bundgaard
UMUlrik M. Mogensen
Ulrik M. Mogensen
SCStefan Christensen
Stefan Christensen
UPUffe Ploug
Uffe Ploug
RRRasmus Rørth
Rasmus Rørth
LKLars Køber
Lars Køber
Background: Heart failure (HF) imposes a large burden on both the individual and the society. The aim of this study was to investigate the economic burden (either direct or indirect costs) attributed to patients with HF before, at, and after time of diagnosis. Methods and results: Using Danish nationwide registries we identified all patients > 18 years with a first-time diagnosis of HF from 1998–2016 and matched them 1:1 with a control group from the background population on age, gender, marital status, and educational level. The economic analysis of the total costs after diagnosis was based on direct costs including hospitalization, procedures, medication, and indirect costs including social welfare and lost productivity to estimate the annual cost of HF. A total of 176 067 HF patients with a median age of 76 (interquartile range 67–84) years and 55% male were included. Patients with HF incurred an average of €17 039 in total annual direct (€11 926) and indirect (€5113) healthcare costs peaking at year of diagnosis compared to €5936 in the control group with the majority attributable to inpatient admissions. The total annual net costs including public transfer after index HF were €11 957 higher in patients with HF compared to controls and the economic consequences were evident more than 2 years prior to the diagnosis of HF. Conclusion: Patients with HF impose significantly higher total annual healthcare costs compared to a matched control group with findings evident more than 2 years prior to HF diagnosis.

22 February 2019 in EP Europace
Verified
Journal Article
Closed access
JBJohan Bundgaard
Johan Bundgaard
JTJens J Thune
Jens J Thune
JNJens C Nielsen
Jens C Nielsen
RVRegitze Videbæk
Regitze Videbæk
JHJens Haarbo
Jens Haarbo
UMUlrik M Mogensen
Ulrik M Mogensen
The Danish Study to Assess the Efficacy of Implantable Cardioverter-Defibrillators (ICD) in Patients with Non-ischaemic Systolic Heart Failure (HF) on Mortality (DANISH) found no overall effect on all-cause mortality. The effect of ICD implantation on health-related quality of life (HRQoL) remains to be established as previous trials have demonstrated conflicting results. We investigated the impact of ICD implantation on HRQoL in patients with non-ischaemic systolic HF, a prespecified secondary endpoint in DANISH. In DANISH, a total of 1116 patients with non-ischaemic systolic HF were randomly assigned (1:1) to ICD implantation or usual clinical care (control). Patients completed disease-specific HRQoL as assessed by Minnesota Living with Heart Failure Questionnaire (MLHFQ; 0-105, high indicating worse). Changes in HRQoL 8 months after randomization were assessed with a mixed-effects model. At randomization, MLHFQ was completed by 935 (84%) patients (n = 472 in the ICD group and n = 463 in the control group) and was reassessed in 274 (58%) and 292 (63%) patients, respectively after 8 months for the primary analysis. Patients in the ICD group vs. the control group had similar improvements in MLHFQ after 8 months [least square mean -7.0 vs. -4.2 (P = 0.13)]. A clinically relevant improvement (decrease ≥5) in the MLHFQ overall score at 8 months was observed in 151 patients in the ICD group and 148 patients in the control group [55% vs. 51%, respectively (P = 0.25)]. Implantable cardioverter-defibrillator implantation in patients with non-ischaemic systolic HF did not significantly alter HRQoL compared with patients randomized to usual clinical care.