Elke Kossel

Dr. Elke Kossel

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2008 in Obesity Facts
Verified
Journal Article
Closed access
PDF file
ABAnja Bosy-Westphal
Anja Bosy-Westphal
WLWiebke Later
Wiebke Later
BHBritta Hitze
Britta Hitze
TSTetsuya Sato
Tetsuya Sato
EKElke Kossel
Elke Kossel
MMManfred James Müller
Manfred James Müller
Objective: To compare body composition determined by bioelectrical impedance (BIA) consumer devices against criterion estimates determined by whole body magnetic resonance imaging (MRI) and dual energy X-ray absorptiometry (DXA) in healthy normal weight, overweight and obese adults. Methods: In 106 adults (54 females, 52 males, age 54.2 ± 16.1 years, BMI 25.8 ± 4.4 kg/m2) fat mass (FM), skeletal muscle mass (SM), total body bone-free lean mass (TBBLM), and level of visceral fat mass (VF) were estimated by 3 single-frequency bipedal (foot-to-foot) and one tretrapolar BIA device, and compared to body composition measured by MRI and DXA. Bland-Altman and simple linear regression analyses were used to determine agreement between methods. Results: %FMDXA, SMMRI or TBBLMDXA showed good relative and absolute agreement with two bipolar and one tetrapolar instrument (r2 = 0.92–0.96; all p < 0.001; mean bias <1.5 %FM and <1 kg SM or TBBLM) and less relative and absolute agreement for another bipolar device (r2 = 0.82 and 0.84, mean bias ∼3 %FM and ∼3 kg SM). The 95% limits of agreement (bias ± 2 SD) were narrowest for the tetrapolar device (–6.59 to 4.61 %FM and –4.62 to 4.74 kg SM) and widest for bipolar instruments (up to –14.54 to 8.58 %FM and –9.52 to 3.92 kg SM). Systematic biases for %FM were found for all bipedal devices, but not for the tetrapolar instrument. Conclusion: Because of the lower agreement between foot-to-foot BIA and DXA or MRI for the assessment of body composition in individuals, tetrapolar electrode arrangement should be preferred for individual or public use. Bipolar devices provide accurate results for field studies with group estimation.

1 October 2009 in The American Journal of Clinical Nutrition
Verified
Journal Article
Open access
PDF file
ABAnja Bosy-Westphal
Anja Bosy-Westphal
EKElke Kossel
Elke Kossel
KGKristin Goele
Kristin Goele
WLWiebke Later
Wiebke Later
BHBritta Hitze
Britta Hitze
MMManfred J Müller
Manfred J Müller
Background: Weight loss leads to reduced resting energy expenditure (REE) independent of fat-free mass (FFM) and fat mass (FM) loss, but the effect of changes in FFM composition is unclear.

1 May 2010 in The Journal of Nutrition
Verified
Journal Article
Open access
PDF file
ABAnja Bosy-Westphal
Anja Bosy-Westphal
CBChristiane-Alena Booke
Christiane-Alena Booke
TBThordis Blöcker
Thordis Blöcker
EKElke Kossel
Elke Kossel
KGKristin Goele
Kristin Goele
MMManfred J Müller
Manfred J Müller
Following experts' consensus, waist circumference (WC) is the best anthropometric obesity index. However, different anatomic sites are used, and curr

11 June 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKS. Krause
S. Krause
MMM. Molari
M. Molari
EGE. V. Gorb
E. V. Gorb
SGS. N. Gorb
S. N. Gorb
EKElke Kossel
Elke Kossel
MHM. Haeckel
M. Haeckel
The fate of plastic debris entering the oceans is largely unconstrained. Currently, intensified research is devoted to the abiotic and microbial degradation of plastic floating near the ocean surface for an extended period of time. In contrast, the impacts of environmental conditions in the deep sea on polymer properties and rigidity are virtually unknown. Here, we present unique results of plastic items identified to have been introduced into deep-sea sediments at a water depth of 4150 m in the eastern equatorial Pacific Ocean more than two decades ago. The results, including optical, spectroscopic, physical and microbial analyses, clearly demonstrate that the bulk polymer materials show no apparent sign of physical or chemical degradation. Solely the polymer surface layers showed reduced hydrophobicity, presumably caused by microbial colonization. The bacterial community present on the plastic items differed significantly (p < 0.1%) from those of the adjacent natural environment by a dominant presence of groups requiring steep redox gradients (Mesorhizobium, Sulfurimonas) and a remarkable decrease in diversity. The establishment of chemical gradients across the polymer surfaces presumably caused these conditions. Our findings suggest that plastic is stable over extended times under deep-sea conditions and that prolonged deposition of polymer items at the seafloor may induce local oxygen depletion at the sediment-water interface.

25 June 2012 in Energies
Verified
Journal Article
Open access
PDF file
CDChristian Deusner
Christian Deusner
NBNikolaus Bigalke
Nikolaus Bigalke
EKElke Kossel
Elke Kossel
MHMatthias Haeckel
Matthias Haeckel
The recovery of natural gas from CH4-hydrate deposits in sub-marine and sub-permafrost environments through injection of CO2 is considered a suitable strategy towards emission-neutral energy production. This study shows that the injection of hot, supercritical CO2 is particularly promising. The addition of heat triggers the dissociation of CH4-hydrate while the CO2, once thermally equilibrated, reacts with the pore water and is retained in the reservoir as immobile CO2-hydrate. Furthermore, optimal reservoir conditions of pressure and temperature are constrained. Experiments were conducted in a high-pressure flow-through reactor at different sediment temperatures (2 °C, 8 °C, 10 °C) and hydrostatic pressures (8 MPa, 13 MPa). The efficiency of both, CH4 production and CO2 retention is best at 8 °C, 13 MPa. Here, both CO2- and CH4-hydrate as well as mixed hydrates can form. At 2 °C, the production process was less effective due to congestion of transport pathways through the sediment by rapidly forming CO2-hydrate. In contrast, at 10 °C CH4 production suffered from local increases in permeability and fast breakthrough of the injection fluid, thereby confining the accessibility to the CH4 pool to only the most prominent fluid channels. Mass and volume balancing of the collected gas and fluid stream identified gas mobilization as equally important process parameter in addition to the rates of methane hydrate dissociation and hydrate conversion. Thus, the combination of heat supply and CO2 injection in one supercritical phase helps to overcome the mass transfer limitations usually observed in experiments with cold liquid or gaseous CO2.

1 November 2016 in Earth and Planetary Science Letters
Verified
Journal Article
Closed access
FSFlorian Scholz
Florian Scholz
CLCarolin R. Löscher
Carolin R. Löscher
AFAnnika Fiskal
Annika Fiskal
SSStefan Sommer
Stefan Sommer
CHChristian Hensen
Christian Hensen
DCDonald E. Canfield
Donald E. Canfield