The efficiency of bidirectional inductive power transfer (BIPT) systems is strongly dependent on the load. Besides, soft switching operation of power switches is critical to high frequency converter in BIPT systems. In this paper, a triple-phase-shift (TPS) control strategy is proposed to achieve load matching while realizing zero voltage switching (ZVS) for all power switches within entire power range. The load matching condition of bidirectional inductive power transfer system with double-sided LCC compensation network is analyzed. And a dual side phase shift control is proposed to adjust power flow while realizing load matching. To realize ZVS operation, the third phase shift between primary and secondary side is introduced as an extra control variable. A time domain model of double-sided LCC compensation network is established to analyze the ZVS range. With the proposed TPS control, wide ZVS operation range of system can be achieved while maintaining load matching. At last, a scale down prototype of 1kW BIPT system is developed. The experimental results show good agreement with theoretical analysis, all switches realize ZVS within entire power range and a peak efficiency of 94.83% is achieved.
14 October 2019 in IEEE Transactions on Power Electronics
In Inductive power transfer (IPT) systems, zero-voltage-switching (ZVS) operation within wide power range is an urgent requirement to improve system efficiency and reduce electromagnetic interference. The combination of phase shift (PS) control and variable frequency control is usually adopted to realize ZVS operation. However, in Inductor-Capacitor-Capacitor-Series (LCC-S) systems, the above-mentioned hybrid strategy cannot be used directly due to non-negligible harmonics, which result in detection difficulties or imprecise calculation of turn-off current. To solve this problem, this paper proposes an optimal variable frequency phase shift (VFPS) control strategy for LCC-S systems to realize ZVS operation within wide power range. The universal harmonic-considered time-domain model of LCC-S system is deduced, and thus the switching-moment current of power switches can be calculated accurately. Based on this value, an optimal working trajectory for ZVS operation with minimum frequency variation is presented. Finally, a 2.2kW IPT prototype is built up to verify the universality of the deduced model and the validity of the proposed optimal VFPS control. Compared with PS control and the VFPS control based on fundamental-harmonic-approximation method, the systems realizes ZVS operation under wide power range with efficiency increase of 2.6%-6.9% and 0.8%-8.8% respectively, and a peak efficiency of 96.4% is achieved.
In this paper, a hybrid model that considers both accuracy and efficiency is proposed to predict photovoltaic (PV) power generation. To achieve this, improved forward feature selection is applied to obtain the optimal feature set, which aims to remove redundant information and obtain related features, resulting in a significant improvement in forecasting accuracy and efficiency. The prediction error is irregularly distributed. Thus, a bias compensation–long short-term memory (BC–LSTM) network is proposed to minimize the prediction error. The experimental results show that the new feature selection method can improve the prediction accuracy by 0.6% and the calculation efficiency by 20% compared to using feature importance identification based on LightGBM. The BC–LSTM network can improve accuracy by 0.3% using about twice the time compared with the LSTM network, and the hybrid model can further improve prediction accuracy and efficiency based on the BC–LSTM network.
Analyzing of the disadvantage of artificial potential field (APF) for mobile robot obstacle avoidance, local trap and vibrating, a new method for improving artificial potential field was proposed in this paper. A new force function was built and the simulation was done. It was approved from the simulation result that local trap was eliminated effectively and vibrating was mitigated but not eliminated through adjusting the parameters of the functions. Referencing to man driving car, the potential force area of mobile robot obstacle avoidance was limited and adjusted at any moment. The problem of mobile robot obstacle avoidance based-on APF was eliminated and the rapidness of arriving at the target was improved by this method.
Slightly unbalanced grid voltage can cause large unbalanced current and non‐characteristic harmonics in three‐phase uncontrolled rectifier. This study proposes an accurate model to analyse the performance of three‐phase uncontrolled rectifier in slightly unbalanced grid. Three appreciative operation modes (three‐phase rectifier, double‐phase rectifier and single‐phase rectifier with discontinuous rectifier current) in slightly unbalanced grid are discussed in detail in this study. Moreover, the closed‐form analytical expressions for boundaries of modes are also derived. To further aid the designer, the curves of current unbalance, third harmonic current, output average voltage, output voltage droop and output voltage harmonic as function of loads under the condition of 2% voltage imbalance are illustrated. Then the design procedure of capacitor is given considering the influence of unbalance and harmonics in slightly unbalanced grid. Finally, a design case is expressed. The design results are realised in a 5 kW three‐phase uncontrolled rectifier to verify the accuracy of the proposed models. The proposed model provides a tool for rapidly and accurately judging the impact of various loads on the rectifier performance in slightly unbalanced grid.