Henryk Skarzynski

Prof. Henryk Skarzynski

Institute of Physiology and Pathology of Hearing
orcid

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2012 in Audiology and Neurotology
Verified
Journal Article
Closed access
PDF file
PBPeter Blamey
Peter Blamey
FAFrançoise Artieres
Françoise Artieres
DBDeniz Başkent
Deniz Başkent
FBFrançois Bergeron
François Bergeron
ABAndy Beynon
Andy Beynon
DLDiane S. Lazard
Diane S. Lazard
Objective: To update a 15-year-old study of 800 postlinguistically deaf adult patients showing how duration of severe to profound hearing loss, age at cochlear implantation (CI), age at onset of severe to profound hearing loss, etiology and CI experience affected CI outcome. Study Design: Retrospective multicenter study. Methods: Data from 2251 adult patients implanted since 2003 in 15 international centers were collected and speech scores in quiet were converted to percentile ranks to remove differences between centers. Results: The negative effect of long duration of severe to profound hearing loss was less important in the new data than in 1996; the effects of age at CI and age at onset of severe to profound hearing loss were delayed until older ages; etiology had a smaller effect, and the effect of CI experience was greater with a steeper learning curve. Patients with longer durations of severe to profound hearing loss were less likely to improve with CI experience than patients with shorter duration of severe to profound hearing loss. Conclusions: The factors that were relevant in 1996 were still relevant in 2011, although their relative importance had changed. Relaxed patient selection criteria, improved clinical management of hearing loss, modifications of surgical practice, and improved devices may explain the differences.

9 November 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DLDiane S. Lazard
Diane S. Lazard
CVChristophe Vincent
Christophe Vincent
FVFrédéric Venail
Frédéric Venail
CHCaroline Van De Heyning
Caroline Van De Heyning
ETEric Truy
Eric Truy
PBPeter J. Blamey
Peter J. Blamey
To test the influence of multiple factors on cochlear implant (CI) speech performance in quiet and in noise for postlinguistically deaf adults, and to design a model of predicted auditory performance with a CI as a function of the significant factors. Retrospective multi-centre study. Data from 2251 patients implanted since 2003 in 15 international centres were collected. Speech scores in quiet and in noise were converted into percentile ranks to remove differences between centres. The influence of 15 pre-, per- and postoperative factors, such as the duration of moderate hearing loss (mHL), the surgical approach (cochleostomy or round window approach), the angle of insertion, the percentage of active electrodes, and the brand of device were tested. The usual factors, duration of profound HL (pHL), age, etiology, duration of CI experience, that are already known to have an influence, were included in the statistical analyses. The significant factors were: the pure tone average threshold of the better ear, the brand of device, the percentage of active electrodes, the use of hearing aids (HAs) during the period of pHL, and the duration of mHL. A new model was designed showing a decrease of performance that started during the period of mHL, and became faster during the period of pHL. The use of bilateral HAs slowed down the related central reorganization that is the likely cause of the decreased performance.

1 July 2013 in Ear & Hearing
Verified
Journal Article
Closed access
RGRené H. Gifford
René H. Gifford
MDMichael F. Dorman
Michael F. Dorman
Henryk SkarzynskiHenryk Skarzynski
Henryk Skarzynski
ALArtur Lorens
Artur Lorens
MPMarek Polak
Marek Polak
CBCraig A. Buchman
Craig A. Buchman
Objective: The aim of this study was to assess the benefit of having preserved acoustic hearing in the implanted ear for speech recognition in complex listening environments. Design: The present study included a within-subjects, repeated-measures design including 21 English-speaking and 17 Polish-speaking cochlear implant (CI) recipients with preserved acoustic hearing in the implanted ear. The patients were implanted with electrodes that varied in insertion depth from 10 to 31 mm. Mean preoperative low-frequency thresholds (average of 125, 250, and 500 Hz) in the implanted ear were 39.3 and 23.4 dB HL for the English- and Polish-speaking participants, respectively. In one condition, speech perception was assessed in an eight-loudspeaker environment in which the speech signals were presented from one loudspeaker and restaurant noise was presented from all loudspeakers. In another condition, the signals were presented in a simulation of a reverberant environment with a reverberation time of 0.6 sec. The response measures included speech reception thresholds (SRTs) and percent correct sentence understanding for two test conditions: CI plus low-frequency hearing in the contralateral ear (bimodal condition) and CI plus low-frequency hearing in both ears (best-aided condition). A subset of six English-speaking listeners were also assessed on measures of interaural time difference thresholds for a 250-Hz signal. Results: Small, but significant, improvements in performance (1.7–2.1 dB and 6–10 percentage points) were found for the best-aided condition versus the bimodal condition. Postoperative thresholds in the implanted ear were correlated with the degree of electric and acoustic stimulation (EAS) benefit for speech recognition in diffuse noise. There was no reliable relationship among measures of audiometric threshold in the implanted ear nor elevation in threshold after surgery and improvement in speech understanding in reverberation. There was a significant correlation between interaural time difference threshold at 250 Hz and EAS-related benefit for the adaptive speech reception threshold. Conclusions: The findings of this study suggest that (1) preserved low-frequency hearing improves speech understanding for CI recipients, (2) testing in complex listening environments, in which binaural timing cues differ for signal and noise, may best demonstrate the value of having two ears with low-frequency acoustic hearing, and (3) preservation of binaural timing cues, although poorer than observed for individuals with normal hearing, is possible after unilateral cochlear implantation with hearing preservation and is associated with EAS benefit. The results of this study demonstrate significant communicative benefit for hearing preservation in the implanted ear and provide support for the expansion of CI criteria to include individuals with low-frequency thresholds in even the normal to near-normal range.

16 December 2013 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
Henryk SkarzynskiHenryk Skarzynski
Henryk Skarzynski
CHCaroline Van De Heyning
Caroline Van De Heyning
SAS. Agrawal
S. Agrawal
SAS. L. Arauz
S. L. Arauz
MAM. Atlas
M. Atlas
GMG. Mertens
G. Mertens
The comprehensive Hearing Preservation classification system presented in this paper is suitable for use for all cochlear implant users with measurable pre-operative residual hearing. If adopted as a universal reporting standard, as it was designed to be, it should prove highly beneficial by enabling future studies to quickly and easily compare the results of previous studies and meta-analyze their data. To develop a comprehensive Hearing Preservation classification system suitable for use for all cochlear implant users with measurable pre-operative residual hearing. The HEARRING group discussed and reviewed a number of different propositions of a HP classification systems and reviewed critical appraisals to develop a qualitative system in accordance with the prerequisites. The Hearing Preservation Classification System proposed herein fulfills the following necessary criteria: 1) classification is independent from users' initial hearing, 2) it is appropriate for all cochlear implant users with measurable pre-operative residual hearing, 3) it covers the whole range of pure tone average from 0 to 120 dB; 4) it is easy to use and easy to understand.

1 October 2020 in JAMA Otolaryngology–Head & Neck Surgery
Verified
Journal Article
Closed access
PDF file
CBCraig A. Buchman
Craig A. Buchman
RGRené H. Gifford
René H. Gifford
DHDavid S. Haynes
David S. Haynes
TLThomas Lenarz
Thomas Lenarz
GOGerard O’donoghue
Gerard O’donoghue
TZTerry Zwolan
Terry Zwolan
Importance Cochlear implants are a treatment option for individuals with severe, profound, or moderate sloping to profound bilateral sensorineural hearing loss (SNHL) who receive little or no benefit from hearing aids; however, cochlear implantation in adults is still not routine. Objective To develop consensus statements regarding the use of unilateral cochlear implants in adults with severe, profound, or moderate sloping to profound bilateral SNHL. Design, Setting, and Participants This study was a modified Delphi consensus process that was informed by a systematic review of the literature and clinical expertise. Searches were conducted in the following databases: (1) MEDLINE In-Process & Other Non-Indexed Citations and Ovid MEDLINE, (2) Embase, and (3) the Cochrane Library. Consensus statements on cochlear implantation were developed using the evidence identified. This consensus process was relevant for the use of unilateral cochlear implantation in adults with severe, profound, or moderate sloping to profound bilateral SNHL. The literature searches were conducted on July 18, 2018, and the 3-step Delphi consensus method took place over the subsequent 9-month period up to March 30, 2019. Main Outcomes and Measures A Delphi consensus panel of 30 international specialists voted on consensus statements about cochlear implantation, informed by an SR of the literature and clinical expertise. This vote resulted in 20 evidence-based consensus statements that are in line with clinical experience. A modified 3-step Delphi consensus method was used to vote on and refine the consensus statements. This method consisted of 2 rounds of email questionnaires and a face-to-face meeting of panel members at the final round. All consensus statements were reviewed, discussed, and finalized at the face-to-face meeting. Results In total, 6492 articles were identified in the searches of the electronic databases. After removal of duplicate articles, 74 articles fulfilled all of the inclusion criteria and were used to create the 20 evidence-based consensus statements. These 20 consensus statements on the use of unilateral cochlear implantation in adults with SNHL were relevant to the following 7 key areas of interest: level of awareness of cochlear implantation (1 consensus statement); best practice clinical pathway from diagnosis to surgery (3 consensus statements); best practice guidelines for surgery (2 consensus statements); clinical effectiveness of cochlear implantation (4 consensus statements); factors associated with postimplantation outcomes (4 consensus statements); association between hearing loss and depression, cognition, and dementia (5 consensus statements); and cost implications of cochlear implantation (1 consensus statement). Conclusions and Relevance These consensus statements represent the first step toward the development of international guidelines on best practices for cochlear implantation in adults with SNHL. Further research to develop consensus statements for unilateral cochlear implantation in children, bilateral cochlear implantation, combined electric-acoustic stimulation, unilateral cochlear implantation for single-sided deafness, and asymmetrical hearing loss in children and adults may be beneficial for optimizing hearing and quality of life for these patients.

1 January 2007 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
Henryk SkarzynskiHenryk Skarzynski
Henryk Skarzynski
ALArtur Lorens
Artur Lorens
APAnna Piotrowska
Anna Piotrowska
IAIlona Anderson
Ilona Anderson
Successful hearing preservation is possible in individuals with excellent low frequency hearing. This is possible due to the partial insertion of an atraumatic electrode using an atraumatic round window surgical technique. This paper describes the round window surgical technique used to preserve excellent low frequency hearing in patients receiving partially inserted MED-EL cochlear implant electrodes. Results of preserved low frequency hearing in partial deafness cochlear implantation (PDCI) are reported. The surgical approach is described in detail. Ten subjects received a partial insertion of a standard electrode, using the round window approach. Pure tone audiometry was conducted in the implanted and non-implanted ear preoperatively, at implant fitting and then at 1, 3, 6 and 12 months after initial device fitting. Results show hearing preservation in 9 of the 10 subjects. One subject lost all hearing 2 weeks after cochlear implantation. Hearing has remained essentially stable up to the 1 year postoperative period. Eight of the nine subjects use the cochlear implant together with their natural low frequency hearing; one subject uses a hearing aid in the implanted ear to amplify the low frequencies.