Iurii Katser

Mr. Iurii Katser

Skolkovo Institute of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VKViacheslav Kozitsin
Viacheslav Kozitsin
Iurii KatserIurii Katser
Iurii Katser
DLDmitry Lakontsev
Dmitry Lakontsev
Real-time diagnostics of complex technical systems such as power plants are critical to keep the system in its working state. An ideal diagnostic system must detect any fault in advance and predict the future state of the technical system, so predictive algorithms are used in the diagnostics. This paper proposes a novel, computationally simple algorithm based on the Auto-Regressive Integrated Moving Average model to solve anomaly detection and forecasting problems. The good performance of the proposed algorithm was confirmed in numerous numerical experiments for both anomaly detection and forecasting problems. Moreover, a description of the Autoregressive Integrated Moving Average Fault Detection (ARIMAFD) library, which includes the proposed algorithms, is provided in this paper. The developed algorithm proves to be an efficient algorithm and can be applied to problems related to anomaly detection and technological parameter forecasting in real diagnostic systems.

9 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Iurii KatserIurii Katser
Iurii Katser
VKViacheslav Kozitsin
Viacheslav Kozitsin
VLVictor Lobachev
Victor Lobachev
IMIvan Maksimov
Ivan Maksimov
Offline changepoint detection (CPD) algorithms are used for signal segmentation in an optimal way. Generally, these algorithms are based on the assumption that signal’s changed statistical properties are known, and the appropriate models (metrics, cost functions) for changepoint detection are used. Otherwise, the process of proper model selection can become laborious and time-consuming with uncertain results. Although an ensemble approach is well known for increasing the robustness of the individual algorithms and dealing with mentioned challenges, it is weakly formalized and much less highlighted for CPD problems than for outlier detection or classification problems. This paper proposes an unsupervised CPD ensemble (CPDE) procedure with the pseudocode of the particular proposed ensemble algorithms and the link to their Python realization. The approach’s novelty is in aggregating several cost functions before the changepoint search procedure running during the offline analysis. The numerical experiment showed that the proposed CPDE outperforms non-ensemble CPD procedures. Additionally, we focused on analyzing common CPD algorithms, scaling, and aggregation functions, comparing them during the numerical experiment. The results were obtained on the two anomaly benchmarks that contain industrial faults and failures—Tennessee Eastman Process (TEP) and Skoltech Anomaly Benchmark (SKAB). One of the possible applications of our research is the estimation of the failure time for fault identification and isolation problems of the technical diagnostics.

5 December 2019 in Izvestiya Wysshikh Uchebnykh Zawedeniy, Yadernaya Energetika
Verified
Journal Article
Closed access
Iurii KatserIurii Katser
Iurii Katser
VKVyacheslav Olegovich Kozitsin
Vyacheslav Olegovich Kozitsin
IMIvan Vladimirovich Maksimov
Ivan Vladimirovich Maksimov
The peer-reviewed scientific and technology journal. ISSN: 0204-3327

22 June 2021 in Nuclear Energy and Technology
Verified
Journal Article
Open access
PDF file
Iurii KatserIurii Katser
Iurii Katser
VKVyacheslav O. Kozitsin
Vyacheslav O. Kozitsin
IMIvan V. Maksimov
Ivan V. Maksimov
DLDenis A. Larionov
Denis A. Larionov
KKKonstantin I. Kotsoev
Konstantin I. Kotsoev
The main tasks of diagnostics at nuclear power plants are detection, localization, diagnosis, and prognosis of the development of malfunctions. Analytical algorithms of varying degrees of complexity are used to solve these tasks. Many of these algorithms require pre-processed input data for high-quality and efficient operation. The pre-processing stage can help to reduce the volume of the analyzed data, generate additional informative diagnostic features, find complex dependencies and hidden patterns, discard uninformative source signals and remove noise. Finally, it can produce an improvement in detection, localization and prognosis quality. This overview briefly describes the data collected at nuclear power plants and provides methods for their preliminary processing. The pre-processing techniques are systematized according to the tasks performed. Their advantages and disadvantages are presented and the requirements for the initial raw data are considered. The references include both fundamental scientific works and applied industrial research on the methods applied. The paper also indicates the mechanisms for applying the methods of signal pre-processing in real-time. The overview of the data pre-processing methods in application to nuclear power plants is obtained, their classification and characteristics are given, and the comparative analysis of the methods is presented.

17 April 2023 in Advanced Engineering Research (Rostov-on-Don)
Verified
Journal Article
Open access
PDF file
MMM. S. Mezhov
M. S. Mezhov
VKV. O. Kozitsin
V. O. Kozitsin
Iurii KatserIurii Katser
Iurii Katser
ЮКЮ. Д. Кацер
Ю. Д. Кацер
Introduction. Electronic devices capable of collecting individual telemetry data have opened up prospects for preclinical detection of COVID-19 signs. Known solutions involve the analysis of information that is difficult to obtain at the moment. We are talking, specifically, about the blood condition or a PCR test. This significantly limits the possibility of integrating algorithms with wrist gadgets. At the same time, the cardiovascular system as an object of observation is quite informative, the data collection is well developed. The article describes the problem of detecting covid anomalies in rhythm strips. The work aims at creating a mathematical model based on machine learning algorithms to automate the process of detecting covid abnormalities in the heart rhythm. The possibility of integrating the results obtained with fitness bracelets and smart watches is shown.Materials and Methods. The work involved an open technology stack: Python, Scikit-learn, Lightgbm. When assessing the quality of models for binary classification, metric F1 was used. 229 cardiac rhythm strips (сardiointervalographies) of patients with COVID-19 were studied. The presence or absence of signs of an anomaly was determined taking into account the time of the rhythm strip and the intervals between heartbeats. Deviations that could indicate infection were shown graphically. Based on the exploratory analysis results, a list of signs indicating an anomaly was made.Results. As a result of the work done, a mathematical model was obtained that detected heart rate abnormalities specific to COVID-19 with an accuracy of 83 %. The basic features determining the predictive ability of the model were identified and ranked. They included the current value of the interval between heartbeats, the derivatives at the subsequent and previous points of measuring the duration of the heartbeat, the first derivative at the current point, and the deviation of the current value of the duration of the RR-interval from the median. The first indicator in this list was recognized as the most significant, the last — the least. For machine learning purposes, the potential of five algorithms was evaluated: IsolationForest, LGBMClassifier, RandomForestClassifier, ExtraTreesClassifier, SGDOneClassSVM. The normal and abnormal results of observations in isolation trees were visualized. A parameter was set that corresponded to the probability of regular observation outside the norm, and its value was selected — 0.11. Taking into account this indicator, a graph was constructed for the SGDOneClassSVM model. Based on the data set, using the cross-validation technique, the quality metric was calculated. The case in hand was a rhythm strip with a time series of observations taken in one continuous time interval from one person. A step-by-step process of obtaining averaged metric values for each model was described. In comparison, the highest indicator was recorded for the LGBMClassifier model, the lowest — for SGDOneClassSVM and IsolationForest.Discussion and Conclusions. The resulting mathematical model takes up little space in the memory of a mobile device, i.e., it does not impose significant requirements on computing resources. The solution has an acceptable detection quality for preclinical screening of COVID-19-related cardiovascular disorders. The algorithm detects anomalies in 83 % of cases. Four minutes is enough to record a rhythm strip. The proposed scenario for using an integrated solution is concise and easy to implement. Widespread use of the development can contribute to the detection of COVID-19 at an early stage.

16 June 2026
Verified
Journal Article
Open access
DKDaniil A. Kechik
Daniil A. Kechik
AKAnton Sergeyevich Kozhukhov
Anton Sergeyevich Kozhukhov
MIMakar S. Ippolitov
Makar S. Ippolitov
Iurii KatserIurii Katser
Iurii Katser
Представлен метод идентификации дефектов вращающегося оборудования и оценки степени их развития, основанный на анализе вибрационного отклика механической системы. Метод опирается на физическую модель, описываемую уравнением Лагранжа, и сводит задачу к построению линейной регрессионной модели, параметрами которой являются полюсы передаточной функции системы, а также произведения еe нулей на комплексные амплитуды гармонических возбуждающих сил. Учитывается неравномерность амплитудно-частотной характеристики оборудования, что позволяет существенно уменьшить влияние резонансных явлений и режима эксплуатации на точность идентификации дефектов. Разработанный метод даeт возможность различать дефекты при изменяющейся частоте вращения вала. На основе полученных оценок вычисляется соотношение амплитуд сил на разных частотах, которое не зависит от параметров амплитудно-частотной характеристики и частоты вращения вала. Работоспособность метода подтверждена тестированием на синтезированных бигармонических сигналах для системы с двумя резонансами, а также на реальных сигналах вибрации с испытательного стенда, моделирующего различные виды расцентровки и дисбаланса. Оценка параметров модели выполнялась методом наименьших квадратов в рамках линейной регрессии.