Sergio Moreno

Mr. Sergio Moreno

Electronic and Biomedical Engineering, University of Barcelona, Barcelona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AVAnna Vilà
Anna Vilà
SMSergio Moreno
Sergio Moreno
JCJoan Canals
Joan Canals
Angel DiéguezAngel Diéguez
Angel Diéguez
Lensless microscopy requires the simplest possible configuration, as it uses only a light source, the sample and an image sensor. The smallest practical microscope is demonstrated here. In contrast to standard lensless microscopy, the object is located near the lighting source. Raster optical microscopy is applied by using a single-pixel detector and a microdisplay. Maximum resolution relies on reduced LED size and the position of the sample respect the microdisplay. Contrarily to other sort of digital lensless holographic microscopes, light backpropagation is not required to reconstruct the images of the sample. In a mm-high microscope, resolutions down to 800 nm have been demonstrated even when measuring with detectors as large as 138 μm × 138 μm, with field of view given by the display size. Dedicated technology would shorten measuring time.

22 August 2024 in Education Sciences
Verified
Journal Article
Open access
PDF file
Angel DiéguezAngel Diéguez
Angel Diéguez
JCJoan Canals
Joan Canals
SMSergio Moreno
Sergio Moreno
AVAnna Vilà
Anna Vilà
Gamification is being incorporated into university classrooms due to its educational benefits for students learning, including encouraging student behavior and engagement, and consequently improving learning outcomes. Despite gamification being increasingly used in education, little has been developed related to Very-Large-Scale Integration (VLSI). In this article, we describe two different gamification experiences applied to integrated circuit processing and design in an introductory VLSI design course for Electronic Engineers. While gamification in universities is still not very mature and our experience spans only two academic years, we observed that, with the practice of gamifying part of our course, the topics treated in games were profoundly learned and the experience was very positive in every aspect of the teaching–learning process.

11 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SMSergio Moreno
Sergio Moreno
JCJoan Canals
Joan Canals
VMVictor Moro
Victor Moro
NFNil Franch
Nil Franch
AVAnna Vilà
Anna Vilà
Angel DiéguezAngel Diéguez
Angel Diéguez
Recent research into miniaturized illumination sources has prompted the development of alternative microscopy techniques. Although they are still being explored, emerging nano-light-emitting-diode (nano-LED) technologies show promise in approaching the optical resolution limit in a more feasible manner. This work presents the exploration of their capabilities with two different prototypes. In the first version, a resolution of less than 1 µm was shown thanks to a prototype based on an optically downscaled LED using an LED scanning transmission optical microscopy (STOM) technique. This research demonstrates how this technique can be used to improve STOM images by oversampling the acquisition. The second STOM-based microscope was fabricated with a 200 nm GaN LED. This demonstrates the possibilities for the miniaturization of on-chip-based microscopes.

30 July 2021 in Electronics
Verified
Journal Article
Open access
PDF file
KKKatarzyna Kluczyk-Korch
Katarzyna Kluczyk-Korch
SMSergio Moreno
Sergio Moreno
JCJoan Canals
Joan Canals
Angel DiéguezAngel Diéguez
Angel Diéguez
JGJan Gülink
Jan Gülink
Matthias Auf der MaurMatthias Auf der Maur
Matthias Auf der Maur
GaN-based light emitting diodes (LEDs) have been shown to effectively operate down to nanoscale dimensions, which allows further downscaling the chip-based LED display technology from micro- to nanoscale. This brings up the question of what resolution limit of the illumination pattern can be obtained. We show two different approaches to achieve individually switchable nano-LED arrays. We evaluated both designs in terms of near-field spot size and optical crosstalk between neighboring pixels by using finite difference time domain (FDTD) simulations. The numerical results were compared with the performance data from a fabricated nano-LED array. The outcome underlines the influence of geometry of the LED array and materials used in contact lines on the final illumination spot size and shape.

4 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SMSergio Moreno
Sergio Moreno
VMVictor Moro
Victor Moro
JCJoan Canals
Joan Canals
Angel DiéguezAngel Diéguez
Angel Diéguez
Digital histogram generation for time-resolved measurements with single-photon avalanche diode (SPAD) sensors requires the storage of many timestamp signals. This work presents a mixed-signal time-to-digital converter (TDC) that uses analog storage to achieve an area-efficient design that can be integrated in large SPAD arrays. Fabricated using a 150 nm CMOS process, the prototype occupies an area of only 18.3 µm × 36.5 µm, a notable size reduction compared to conventional designs. The experimental results demonstrated high performance, with an integral nonlinearity (INL) of 0.35/0.14 least significant bit (LSB) and a differential nonlinearity (DNL) of 0.14/−0.12 LSB. In addition, the proposed TDC can support the construction of histograms comprising up to 512 bins, making it an effective solution to accommodate a wide range of resolution requirements. Validated in a point-of-care (PoC) device for fluorescence lifetime measurements, it distinguished between lifetimes of approximately 4.1 ns, 3.6 ns and 80 ns with the Alexa Fluor (AF) 546 and 568 dyes and Quantum Dot (QD) 705, respectively. The analog storage design and area-efficient architecture offer a novel approach to integrating TDCs in SPAD-based systems, with potential applications in medical diagnostics and beyond.

22 May 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
VMVictor Moro
Victor Moro
JCJoan Canals
Joan Canals
SMSergio Moreno
Sergio Moreno
SHSteffen Higgins-Wood
Steffen Higgins-Wood
Oscar AlonsoOscar Alonso
Oscar Alonso
Angel DiéguezAngel Diéguez
Angel Diéguez
A Point-of-Care system for molecular diagnosis (PoC-MD) is described, combining GaN and CMOS chips. The device is a micro-system for fluorescence measurements, capable of analyzing both intensity and lifetime. It consists of a hybrid micro-structure based on a 32 × 32 matrix addressable GaN microLED array, with square LEDs of 50 µm edge length and 100 µm pitch, with an underneath wire bonded custom chip integrating their drivers and placed face-to-face to an array of 16 × 16 single-photon avalanche diodes (SPADs) CMOS. This approach replaces instrumentation based on lasers, bulky optical components, and discrete electronics with a full hybrid micro-system, enabling measurements on 32 × 32 spots. The reported system is suitable for long lifetime (>10 ns) fluorophores with a limit of detection ~1/4 µM. Proof-of-concept measurements of streptavidin conjugate Qdot™ 605 and Amino PEG Qdot™ 705 are demonstrated, along with the device ability to detect both fluorophores in the same measurement.