Ahmed Joubair

Dr. Ahmed Joubair


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2014 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
AJAhmed Joubair
Ahmed Joubair
IBIlian Bonev
Ilian Bonev

10 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MGMartin Gaudreault
Martin Gaudreault
AJAhmed Joubair
Ahmed Joubair
IBIlian Bonev
Ilian Bonev
This work shows the feasibility of calibrating an industrial robot arm through an automated procedure using a new, low-cost, wireless measuring device mounted on the robot’s flange. The device consists of three digital indicators that are fixed orthogonally to each other on an aluminum support. Each indicator has a measuring accuracy of 3 µm. The measuring instrument uses a kinematic coupling platform which allows for the definition of an accurate and repeatable tool center point (TCP). The idea behind the calibration method is for the robot to bring automatically this TCP to three precisely-known positions (the centers of three precision balls fixed with respect to the robot’s base) and with different orientations of the robot’s end-effector. The self-calibration method was tested on a small six-axis industrial robot, the ABB IRB 120 (Vasteras, Sweden). The robot was modeled by including all its geometrical parameters and the compliance of its joints. The parameters of the model were identified using linear regression with the least-square method. Finally, the performance of the calibration was validated with a laser tracker. This validation showed that the mean and the maximum absolute position errors were reduced from 2.628 mm and 6.282 mm to 0.208 mm and 0.482 mm, respectively.

23 April 2019 in Robotics
Verified
Journal Article
Open access
PDF file
NNNicholas Nadeau
Nicholas Nadeau
IBIlian Bonev
Ilian Bonev
AJAhmed Joubair
Ahmed Joubair
This paper presents a closed-loop calibration approach using impedance control. The process is managed by a data communication architecture based on open-source tools and designed for adaptability. The calibration procedure uses precision spheres and a kinematic coupling standard machine tool components, which are suitable for harsh industrial environments. As such, the required equipment is low cost (approximately $2000 USD), robust, and is quick to set up, especially when compared to traditional calibration devices. As demonstrated through an experimental study and validated with a laser tracker, the absolute accuracy of the KUKA LBR iiwa robot was improved to a maximum error of 0.990 mm, representing a 58.4% improvement when compared to the nominal model. Further testing showed that a traditional calibration using a laser tracker only improved the maximum error by 58 µm over the impedance control approach.

31 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
AJAhmed Joubair
Ahmed Joubair
LZLong Fei Zhao
Long Fei Zhao
PBPascal Bigras
Pascal Bigras
IBIlian Bonev
Ilian Bonev
The aim of this paper is to improve the position accuracy of a six degree of freedom medical robot. The improvement in accuracy is achieved without the use of any external measurement device. Instead, this work presents a novel calibration approach based on using an embedded force-torque sensor to identify the robot’s kinematic parameters and thereby enhance the positioning accuracy. A simulation study demonstrated that our calibration approach is effective, whether or not any measurement noise is present: the position error is improved, inside the robot target workspace, from 12 mm to 0.320 mm, for the maximum values, and from 9 mm to 0.2771 mm, for the mean errors.