EMILIA NOORSAL

Dr. EMILIA NOORSAL

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
ENEMILIA NOORSAL
EMILIA NOORSAL
ARAsyraf Rongi
Asyraf Rongi
IIIntan Rahayu Ibrahim
Intan Rahayu Ibrahim
RDRosheila Darus
Rosheila Darus
DKDaniel Kho
Daniel Kho
SSSamsul Setumin
Samsul Setumin
Multilevel inverters are a type of power electronic circuit that converts direct current (DC) to alternating current (AC) for use in high-voltage and high-power applications. Many recent studies on multilevel inverters have used field-programmable gate arrays (FPGAs) as a switching controller device to overcome the limitations of microcontrollers or DSPs, such as limited sampling rate, low execution speed, and a limited number of IO pins. However, the design techniques of most existing FPGA-based switching controllers require large amounts of memory (RAM) for storage of sampled data points as well as complex controller architectures to generate the output gating pulses. Therefore, in this paper, we propose two types of FPGA-based digital switching controllers, namely selective harmonic elimination (SHE) and sinusoidal pulse width modulation (SPWM), for a 21-level multilevel inverter. Both switching controllers were designed with minimal hardware complexity and logic utilisation. The designed SHE switching controller mainly consists of a four-bit finite state machine (FSM) and a 13-bit counter, while the SPWM switching controller employs a simple iterative CORDIC algorithm with a small amount of data storage requirement, a six-bit up-down counter, and a few adders. Initially, both digital switching controllers (SHE and SPWM) were designed using the hardware description language (HDL) in Verilog codes and functionally verified using the developed testbenches. The designed digital switching controllers were then synthesised and downloaded to the Intel FPGA (DE2-115) board for real-time verification purposes. For system-level verification, both switching controllers were tested on five cascaded H-Bridge circuits for a 21-level multilevel inverter model using the HDL co-simulation method in MATLAB Simulink. From the synthesised logic gates, it was found that the designed SHE and SPWM switching controllers require only 186 and 369 logic elements (LEs), respectively, which is less than 1% of the total LEs in an FPGA (Cyclone IV E) chip. The execution speed of the SHE switching controller implemented in the FPGA (Cyclone IV E) chip was found to be a maximum of 99.97% faster when compared with the microcontroller (PIC16F877A). The THD percentage of the 21-level SHE digital switching controller (3.91%) was found to be 37% less than that of the SPWM digital switching controller (6.17%). In conclusion, the proposed simplified design architectures of SHE and SPWM digital switching controllers have been proven to not only require minimal logic resources, achieve high processing speeds, and function correctly when tested on a real-time FPGA board, but also generate the desired 21-level stepped sine-wave output voltage (±360 VPP) at a frequency of 50 Hz with low THD percentages when tested on a 21-level cascaded H-Bridge multilevel inverter model.

16 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
ENEMILIA NOORSAL
EMILIA NOORSAL
SASaharul Arof
Saharul Arof
SYSaiful Zaimy Yahaya
Saiful Zaimy Yahaya
ZHZakaria Hussain
Zakaria Hussain
DKDaniel Kho
Daniel Kho
YAYusnita Mohd Ali
Yusnita Mohd Ali
Functional electrical stimulation (FES) device has been widely used by spinal cord injury (SCI) patients in their rehab exercises to restore motor function to their paralysed muscles. The major challenge of muscle contraction induced by FES is early muscle fatigue due to the open-loop stimulation strategy. To reduce the early muscle fatigue phenomenon, a closed-loop FES system is proposed to track the angle of the limb’s movement and provide an accurate amount of charge according to the desired reference angle. Among the existing feedback controllers, fuzzy logic controller (FLC) has been found to exhibit good control performance in handling complex non-linear systems without developing any complex mathematical model. Recently, there has been considerable interest in the implementation of FLC in hardware embedded systems. Therefore, in this paper, a digital fuzzy feedback controller (FFC) embedded in a field-programmable gate array (FPGA) board was proposed. The digital FFC mainly consists of an analog-to-digital converter (ADC) Data Acquisition and FLC sub-modules. The FFC was designed to monitor and control the progress of knee extension movement by regulating the stimulus pulse width duration to meet the target angle. The knee is expected to extend to a maximum reference angle setting (70°, 40° or 30°) from its normal position of 0° once the stimulus charge is applied to the muscle by the FES device. Initially, the FLC was modelled using MATLAB Simulink. Then, the FLC was hardcoded into digital logic using hardware description language (HDL) Verilog codes. Thereafter, the performance of the digital FLC was tested with a knee extension model using the HDL co-simulation technique in MATLAB Simulink. Finally, for real-time verification, the designed digital FFC was downloaded to the Intel FPGA (DE2-115) board. The digital FFC utilized only 4% of the total FPGA (Cyclone IV E) logic elements (LEs) and required 238 µs to regulate stimulus pulse width data, including 3 µs for the FLC computation. The high processing speed of the digital FFC enables the stimulus pulse width duration to be updated every stimulation cycle. Furthermore, the implemented digital FFC has demonstrated good control performance in accurately controlling the stimulus pulse width duration to reach the desired reference angle with very small overshoot (1.4°) and steady-state error (0.4°). These promising results are very useful for a real-world closed-loop FES application.

12 July 2023 in Machines
Verified
Journal Article
Open access
PDF file
SASaharul Arof
Saharul Arof
ENEMILIA NOORSAL
EMILIA NOORSAL
SYSaiful Zaimy Yahaya
Saiful Zaimy Yahaya
ZHZakaria Hussain
Zakaria Hussain
YAYusnita Mohd Ali
Yusnita Mohd Ali
MSMuhamad Khuzzairie Safie
Muhamad Khuzzairie Safie
Functional electrical stimulation (FES) has been widely used to treat spinal cord injury (SCI) patients. Many research studies employ a closed-loop FES system to monitor the stimulated muscle response and provide a precise amount of charge to the muscle. However, most closed-loop FES devices perform poorly and sometimes fail when muscle nonlinearity effects such as fatigue, time delay response, stiffness, spasticity, and subject change happen. The poor performance of the closed-loop FES device is mainly due to discrepancies in the feedback control algorithms. Most of the existing feedback control algorithms were not designed to adapt to new changes in patients with different nonlinearity effects, resulting in early muscle fatigue. Therefore, this research proposes an adaptive sliding mode (SM) feedback control algorithm that could adapt and fine-tune internal control settings in real-time according to the current subject’s nonlinear and time-varying muscle response during the rehabilitation (knee extension) exercise. The adaptive SM feedback controller consists mainly of system identification, direct torque control, and tunable feedback control settings. Employing the system identification unit in the feedback control algorithm enables real-time self-tuning and adjusting of the SM internal control settings according to the current patient’s condition. Initially, the patient’s knee trajectory response was identified by extracting meaningful information, which included time delay, rise time, overshoot, and steady-state error. The extracted information was used to fine-tune and update the internal SM control settings. Finally, the performance of the proposed adaptive SM feedback control algorithm in terms of system response time, stability, and rehabilitation time was analysed using a nonlinear knee model. The findings from the simulation results indicate that the adaptive SM feedback controller demonstrated the best control performance in accurately tracking the desired knee angle movement by having faster response times, smaller overshoots, and lower steady-state errors when compared with the conventional SM across four reference angle settings (20°, 30°, 40°, and 76°). The adaptive feedback SM controller was also observed to compensate for muscle nonlinearities, including fatigue, stiffness, spasticity, time delay, and other disturbances.

1 February 2020 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
ENEMILIA NOORSAL
EMILIA NOORSAL
SYS. Z. Yahaya
S. Z. Yahaya
ZHZ. Hussain
Z. Hussain
RBR. Boudville
R. Boudville
MIM. N. Ibrahim
M. N. Ibrahim
YAY. Mohd Ali
Y. Mohd Ali
This paper presents the analytical study of flexible stimulation waveforms in muscle fatigue reduction for functional electrical stimulator (FES)-assisted hemiplegic muscle activities. The major challenge of muscle contraction induced by FES is early muscle fatigue which greatly limits activities such as FES-assisted standing and walking. The fixed stimulation pattern applied on a same motor unit has resulted the motor unit to be overworked and fatigue easily. Therefore, in this work, the stimulus parameters, which include the pulse width duration and the frequency were varied to create a few flexible stimulation waveforms using MATLAB/Simulink. The pulse width duration was modulated from 100µs – 500µs to generate five types of flexible stimulation waveforms such as Rectangular, Trapezoidal, Ramp Up, Ramp Down and Triangular. Concurrently, a few ranges of stimulus frequency were also used, which include 20Hz, 30Hz and 50Hz. The generated flexible stimulation waveforms were applied onto a humanoid muscle model to investigate and analyse the muscle output response and early muscle fatigue reduction. From the conducted simulation results and analyses, it was observed that flexible stimulation waveforms such as Triangular, Ramp Up and Ramp Down could reduce early muscle fatigue phenomenon by having lower average of negative slope, in the range of 0.012 to 0.013 for the muscle fitness. In contrast, the Rectangular and Trapezoidal shapes were found to have higher negative slope of muscle fitness in the range of 0.028 to 0.031. The Ramp Down shape was found to have the lowest average of negative slope (0.012) while Rectangular was found to have the highest average of negative slope (0.031). Therefore, it can be concluded that flexible stimulation waveforms such Ramp Down, Ramp Up and Triangular shapes could reduce early muscle fatigue phenomenon with Ramp Down shape having the highest muscle fatigue reduction.

1 April 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
ZAZul Imran Azhari
Zul Imran Azhari
SSSamsul Setumin
Samsul Setumin
ENEMILIA NOORSAL
EMILIA NOORSAL
HAHanafi Abdullah
Hanafi Abdullah
A foggy environment may cause digitally captured images to appear blurry, dim, or low in contrast. This will impact computer vision systems that rely on image information. With the need for real-time image information, such as a plate number recognition system, a simple yet effective image enhancement algorithm using a hardware implementation is very much needed to fulfil the need. To improve images that suffer from low exposure and hazy, the hardware implementations are usually based on complex algorithms. Hence, the aim of this paper is to propose a less complex enhancement algorithm for hardware implementation that is able to improve the quality of such images. The proposed method simply combines brightness and contrast manipulation to enhance the image. In order to see the performance of the proposed method, a total of 100 vehicle registration number images were collected, enhanced, and evaluated. The evaluation results were compared to two other enhancement methods quantitatively and qualitatively. Quantitative evaluation is done by evaluating the output image using peak signal-to-noise ratio and mean-square error evaluation metrics, while a survey is done to evaluate the output image qualitatively. Based on the quantitative evaluation results, our proposed method outperforms the other two enhancement methods.

1 November 2022 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
YAYusnita Mohd Ali
Yusnita Mohd Ali
ENEMILIA NOORSAL
EMILIA NOORSAL
NMNor Fadzilah Mokhtar
Nor Fadzilah Mokhtar
SSSiti Zubaidah Md Saad
Siti Zubaidah Md Saad
HAHanafi Abdullah
Hanafi Abdullah
Chee Chin LimChee Chin Lim
Chee Chin Lim
Gender discrimination and awareness are essentially practiced in social, education, workplace, and economic sectors across the globe. A person manifests this attribute naturally in gait, body gesture, facial, including speech. For that reason, automatic gender recognition (AGR) has become an interesting sub-topic in speech recognition systems that can be found in many speech technology applications. However, retrieving salient gender-related information from a speech signal is a challenging problem since speech contains abundant information apart from gender. The paper intends to compare the performance of human vocal tract-based model i.e., linear prediction coefficients (LPC) and human auditory-based model i.e., Mel-frequency cepstral coefficients (MFCC) which are popularly used in other speech recognition tasks by experimentation of optimal feature parameters and classifier’s parameters. The audio data used in this study was obtained from 93 speakers uttering selected words with different vowels. The two feature vectors were tested using two classification algorithms namely, discriminant analysis (DA) and artificial neural network (ANN). Although the experimental results were promising using both feature parameters, the best overall accuracy rate of 97.07% was recorded using MFCC-ANN techniques with almost equal performance for male and female classes.