Shayaan Saghir

Mr. Shayaan Saghir

National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
MSMuhammad Mubasher Saleem
Muhammad Mubasher Saleem
Shayaan SaghirShayaan Saghir
Shayaan Saghir
SBSyed Ali Raza Bukhari
Syed Ali Raza Bukhari
AHAmir Hamza
Amir Hamza
RSRana Iqtidar Shakoor
Rana Iqtidar Shakoor
SBShafaat Ahmed Bazaz
Shafaat Ahmed Bazaz
This paper presents a new design of microelectromechanical systems (MEMS) based low-g accelerometer utilizing mode-localization effect in the three degree-of-freedom (3-DoF) weakly coupled MEMS resonators. Two sets of the 3-DoF mechanically coupled resonators are used on either side of the single proof mass and difference in the amplitude ratio of two resonator sets is considered as an output metric for the input acceleration measurement. The proof mass is electrostatically coupled to the perturbation resonators and for the sensitivity and input dynamic range tuning of MEMS accelerometer, electrostatic electrodes are used with each resonator in two sets of 3-DoF coupled resonators. The MEMS accelerometer is designed considering the foundry process constraints of silicon-on-insulator multi-user MEMS processes (SOIMUMPs). The performance of the MEMS accelerometer is analyzed through finite-element-method (FEM) based simulations. The sensitivity of the MEMS accelerometer in terms of amplitude ratio difference is obtained as 10.61/g for an input acceleration range of ±2 g with thermomechanical noise based resolution of 0.22 μμg/Hz and nonlinearity less than 0.5%.

30 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Shayaan SaghirShayaan Saghir
Shayaan Saghir
MSMuhammad Mubasher Saleem
Muhammad Mubasher Saleem
AHAmir Hamza
Amir Hamza
KRKashif Riaz
Kashif Riaz
SISohail Iqbal
Sohail Iqbal
RSRana Iqtidar Shakoor
Rana Iqtidar Shakoor
This paper presents a systematic and efficient design approach for the two degree-of-freedom (2-DoF) capacitive microelectromechanical systems (MEMS) accelerometer by using combined design and analysis of computer experiments (DACE) and Gaussian process (GP) modelling. Multiple output responses of the MEMS accelerometer including natural frequency, proof mass displacement, pull-in voltage, capacitance change, and Brownian noise equivalent acceleration (BNEA) are optimized simultaneously with respect to the geometric design parameters, environmental conditions, and microfabrication process constraints. The sampling design space is created using DACE based Latin hypercube sampling (LHS) technique and corresponding output responses are obtained using multiphysics coupled field electro–thermal–structural interaction based finite element method (FEM) simulations. The metamodels for the individual output responses are obtained using statistical GP analysis. The developed metamodels not only allowed to analyze the effect of individual design parameters on an output response, but to also study the interaction of the design parameters. An objective function, considering the performance requirements of the MEMS accelerometer, is defined and simultaneous multi-objective optimization of the output responses, with respect to the design parameters, is carried out by using a combined gradient descent algorithm and desirability function approach. The accuracy of the optimization prediction is validated using FEM simulations. The behavioral model of the final optimized MEMS accelerometer design is integrated with the readout electronics in the simulation environment and voltage sensitivity is obtained. The results show that the combined DACE and GP based design methodology can be an efficient technique for the design space exploration and optimization of multiphysics MEMS devices at the design phase of their development cycle.

12 September 2025 in Proceedings
Verified
Conference Paper
Open access
PDF file
Shayaan SaghirShayaan Saghir
Shayaan Saghir
RTRachael C Tighe
Rachael C Tighe
YKYe Chow Kuang
Ye Chow Kuang
In nondestructive evaluation (NDE), pulsed phase thermography (PPT) is a commonly used technique which relies on phase contrast to detect defects. This study presents a methodology to investigate how changes in signal processing and geometrical parameters affect phase contrast. Analytically simulated thermal signals are used to evaluate the phase contrast for varying sample thicknesses and defect sizes, relative to a fixed defect depth. To address the issue of spectral leakage, phase contrasts are recorded using both rectangular and Hamming windows before transformation into the frequency domain. A Gaussian process regression (GPR) modelling scheme is used to observe the relationship between phase contrast and geometrical parameters. The results suggest that both the choice of windowing function and geometrical factors can influence defect detection, offering insights to improve the reliability of PPT-based inspections.