Jiayu Li

Dr. Jiayu Li

Berkeley Education Alliance for Research in Singapore, Singapore 138602, Singapore
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Aerosol and Air Quality Research
Verified
Journal Article
Open access
PDF file
Jiayu LiJiayu Li
Jiayu Li
FTFederico Tartarini
Federico Tartarini
On the 7th of April, the Singaporean government enforced strict lockdown measures with the aim of reducing the transmission chain of the coronavirus disease 2019. This had a significant impact on the movement of people within the country. Our study aims to quantify the impact that these measures had on outdoor air pollution levels. We obtained air quality data from April 2016 to May 2020 from five weather and air quality stations in Singapore as well as mobility data for 2020 from Apple, Google, and the Singaporean Housing & Development Board. We determined that outdoor air pollution during the lockdown significantly decreased when compared with the same period in the previous four years even if we included corrections for long time trends in the analysis. The concentrations of the following pollutants PM10, PM2.5, NO2, CO, and SO2 decreased by 23, 29, 54, 6, and 52%, respectively, whilst that of O3 increased by 18%. The Pollutant Standard Index decreased by 19%. The trends of PM2.5 and NO2 were significantly correlated with mobility data. The NO2 and SO2 tropospheric concentrations and the total aerosol optical depth at 550nm obtained from satellite data during the lockdown in 2020 were also lower than during the same period in 2019. Our results can be used to evaluate possible mitigation strategies for outdoor air quality in a longer term beyond this lockdown.

2 August 2023 in Building and Environment
Verified
Journal Article
Open access
Michael KentMichael Kent
Michael Kent
NHNam Khoa Huynh
Nam Khoa Huynh
AMAsit Kumar Mishra
Asit Kumar Mishra
FTFederico Tartarini
Federico Tartarini
ALAleksandra Lipczynska
Aleksandra Lipczynska
SSStefano Schiavon
Stefano Schiavon

1 December 2014 in Building and Environment
Verified
Journal Article
Closed access
XCXiaodong Cao
Xiaodong Cao
Junjie LiuJunjie Liu
Junjie Liu
JPJingjing Pei
Jingjing Pei
YZYun Zhang
Yun Zhang
Jiayu LiJiayu Li
Jiayu Li
XZXueliang Zhu
Xueliang Zhu

1 November 2015 in Building and Environment
Verified
Journal Article
Closed access
Jiayu LiJiayu Li
Jiayu Li
XCXiaodong Cao
Xiaodong Cao
Junjie LiuJunjie Liu
Junjie Liu
CWCongcong Wang
Congcong Wang
YZYongzhi Zhang
Yongzhi Zhang

1 November 2017 in Aerospace Science and Technology
Verified
Journal Article
Closed access
YZYongzhi Zhang
Yongzhi Zhang
Junjie LiuJunjie Liu
Junjie Liu
JPJingjing Pei
Jingjing Pei
Jiayu LiJiayu Li
Jiayu Li
CWCongcong Wang
Congcong Wang

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
YHYuefei Hou
Yuefei Hou
Junjie LiuJunjie Liu
Junjie Liu
Jiayu LiJiayu Li
Jiayu Li
In recent IAQ studies, there is much concern about air quality in school buildings. This paper focuses on indoor air quality in classrooms of two primary schools in Beijing, China. Ventilation rates, CO2 and PM2.5 are measured and analyzed. The results show that ventilation rates in naturally ventilated classrooms with windows and doors closed are less than 1 l/s/p, and CO2 concentration during class hours can increase over 2500ppm within a class. And also, closing windows and doors can only partly prevent outdoor PM2.5 from entering into indoor air, and indoor PM2.5 concentrations are 60∼70% of outdoor. To insure good indoor air quality in primary schools, mechanical ventilation devices with air purification function should be introduced in