Plant fibres and especially flax can be distinguished from most synthetic fibres by their intricate shape and intrinsic porosity called lumen, which is usually assumed to be tubular. However, the real shape appears more complex and thus might induce stress concentrations influencing the fibre performance. This study proposes a novel representation of flax fibre lumen and its variations along the fibre, an interpretation of its origin and effect on flax fibre tensile properties. This investigation was conducted at the crossroads of complementary characterization techniques: optical and scanning electron microscopy (SEM), high-resolution X-ray microtomography (µCT) and mechanical tests at the cell-wall and fibre scale by atomic force microscopy (AFM) in Peak-Force Quantitative Nano-Mechanical property mapping (PF-QNM) mode and micromechanical tensile testing. Converging results highlight the difficulty of drawing a single geometric reference for the lumen. AFM and optical microscopy depict central cavities of different sizes and shapes. Porosity contents, varying from 0.4 to 7.2%, are estimated by high-resolution µCT. Furthermore, variations of lumen size are reported along the fibres. This intricate lumen shape might originate from the cell wall thickening and cell death but particular attention should also be paid to the effects of post mortem processes such as drying, retting and mechanical extraction of the fibre as well as sample preparation. Finally, SEM observation following tensile testing demonstrates the combined effect of geometrical inhomogeneities such as defects and intricate lumen porosity to drive the failure of the fibre.
Hemp concrete is a sustainable lightweight concrete that became popular in the field of building construction because of its thermal and environmental properties. However; available experimental data on its hygrothermal behavior are rather scarce in the literature. This paper describes the design of a large-scale experiment developed to investigate the hygrothermal behavior of hemp concrete cast around a timber frame through a spraying process; and then coated with lime-based plaster. The equipment is composed of two climatic chambers surrounding the tested wall. The experiment consists of maintaining the indoor climate at constant values and applying incremental steps of temperature; relative humidity or vapor pressure in the outdoor chamber. Temperature and relative humidity of the room air and on various depths inside the wall are continuously registered during the experiments and evaporation phenomena are observed. The influence of the plaster on the hygrothermal behavior of hemp concrete is investigated. Moreover; a comparison of experimental temperatures with numerical results obtained from a purely conductive thermal model is proposed. Comparing the model with the measured data gave satisfactory agreement.
15 November 2017 in Industrial & Engineering Chemistry Research