Colorectal cancer (CRC) is a highly prevalent malignancy with multifactorial etiology, which includes metabolic alterations as contributors to disease development. Studies have shown that lipid status disorders are involved in colorectal carcinogenesis. In line with this, previous studies have also suggested that the serum high-density lipoprotein cholesterol (HDL-C) level decreases in patients with CRC, but more recently, the focus of investigations has shifted toward the exploration of qualitative properties of HDL in this malignancy. Herein, a comprehensive overview of available evidences regarding the putative role of HDL in CRC will be presented. We will analyze existing findings regarding alterations of HDL-C levels but also HDL particle structure and distribution in CRC. In addition, changes in HDL functionality in this malignancy will be discussed. Moreover, we will focus on the genetic regulation of HDL metabolism, as well as the involvement of HDL in disturbances of cholesterol trafficking in CRC. Finally, possible therapeutic implications related to HDL will be presented. Given the available evidence, future studies are needed to resolve all raised issues concerning the suggested protective role of HDL in CRC, its presumed function as a biomarker, and eventual therapeutic approaches based on HDL.
16 October 2019 in Journal of Medical Biochemistry
Summary: Background: Non-cholesterol sterols (NCS) are promising biomarkers for estimation of cholesterol homeostasis properties. In addition, determination of NCS in high-density lipoprotein (HDL) fraction (HDL-NCS) could provide information on cholesterol efflux. However, matrix effects interfere in liquid chromatography–mass spectrometry (LC-MS) analysis of NCS, thereby impairing the method sensitivity. The aims of this study were development, optimization and validation of LC-MS method for quantification of NCS in serum and HDL-NCS. Additionally, matrix effect interferences and methods application in individual serum samples were examined. Methods: HDL precipitating reagent was used for HDL isolation. Matrix effect was examined by comparing different surrogates by simple regression analysis. Validation was conducted according to the FDA-ICH guideline. 20 healthy volunteers were recruited for testing of method application. Results: The observed matrix effect was 30%, and matrix comparison showed that cholesterol was the dominant contributor to the matrix effect. Cholesterol concentration was adjusted by construction of the calibration curve for serum and HDL fraction (5 mmol/L and 2.5 mmol/L, respectively). The intra- and inter- run variabilities for NCSs were 4.7–10.3% for serum NCS and 3.6–13.6% for HDL-NCS and 4.6–9.5% for serum NCSs and 2.5–9.8% for HDL-NCS, respectively. Recovery studies showed satisfactory results for NCSs: 89.8–113.1% for serum NCS and 85.3–95.8% for HDL-NCS. Conclusions: The method was successfully developed and optimized. The matrix interference was solved by customising calibration curves for each method and sample type. The measurement of NCS in HDL fraction was proposed for the first time as potentially useful procedure in biomedical researches.
22 June 2017 in International Journal "Advanced Quality"
Method validation is a continuous process, as a part of a perpetual analytical method development and improvement. Requirements for full validation are defined by various guidelines. Nevertheless, partial validation and method transfer are not so clearly described and well defined. The aim of this study was to examine method transferability through full validation method transfer between two different laboratories and to demonstrate if this approach can be regarded as sufficient for cross-laboratory results comparison. Method transfer was done from the originator laboratory to the recipient laboratory on two UHPLC-MS/MS instruments of approximately the same technical characteristics. The developed quantitative method was validated on both instruments by taking into account selectivity, linearity, accuracy, precision, limit of quantitation, recovery, matrix effects and stability in accordance with the regulatory guidance/guideline. Also method comparison by Passing-Bablok regression analysis was done. The reproducibility and cross-laboratory transferability of the UHPLC-MS/MS method for future non-clinical study was proven. As an epilogue to this study, authors recommend for the method transfer to be implemented in future in-house standard operating procedures (SOPs) related to analytical method validation process.