Nikola Šegedin

Mr. Nikola Šegedin

Assistant

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KSKristina Serec
Kristina Serec
NŠNikola Šegedin
Nikola Šegedin
MKMaria Krajačić
Maria Krajačić
Sanja Dolanski BabićSanja Dolanski Babić
Sanja Dolanski Babić
Conformational transitions of double-stranded DNA in different environments have long been studied as vital parts of both in vitro and in vivo processes. In this study, utilizing Fourier transform infrared spectroscopy (FTIR), we provide detailed analysis of dynamics of A- to B-form transitions in DNA thin films of different hydrated states based on a statistical analysis of a substantial number of spectra and band shape analysis (peak fitting) in both the phosphate (1150–1000 cm−1) and sugar–phosphate (900–750 cm−1) region. Hydration of DNA thin films is systematically controlled by the time spent in the desiccator chamber (from 3 min to 40 min) allowing conformation and hydration signatures, in addition to variations due to ambient conditions, to be resolved in the spectra. Conformation transition from A-form to more ordered B-form is observed if sufficient time in the desiccator chamber is allowed and is confirmed by changes on the bands at ≈890, 860, 837, and 805 cm−1. Phosphate vibrations at ≈1230 cm−1 and 1089 cm−1, and backbone vibrations at ≈1030 cm−1 and 765 cm−1 were found to be sensitive to changes in hydration rather than conformation. Additionally, we found that spectral variations caused by ambient conditions can be significantly reduced without inducing conformational changes, which serves as a good basis for quality assurance.

29 June 2021 in Molecules
Verified
Journal Article
Open access
PDF file
OGOzren Gamulin
Ozren Gamulin
MŠMarko Škrabić
Marko Škrabić
KSKristina Serec
Kristina Serec
Matej ParMatej Par
Matej Par
MBMarija Baković
Marija Baković
MVMarin Vodanovic
Marin Vodanovic
Gender determination of the human remains can be very challenging, especially in the case of incomplete ones. Herein, we report a proof-of-concept experiment where the possibility of gender recognition using Raman spectroscopy of teeth is investigated. Raman spectra were recorded from male and female molars and premolars on two distinct sites, tooth apex and anatomical neck. Recorded spectra were sorted into suitable datasets and initially analyzed with principal component analysis, which showed a distinction between spectra of male and female teeth. Then, reduced datasets with scores of the first 20 principal components were formed and two classification algorithms, support vector machine and artificial neural networks, were applied to form classification models for gender recognition. The obtained results showed that gender recognition with Raman spectra of teeth is possible but strongly depends both on the tooth type and spectrum recording site. The difference in classification accuracy between different tooth types and recording sites are discussed in terms of the molecular structure difference caused by the influence of masticatory loading or gender-dependent life events.

25 August 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
NŠNikola Šegedin
Nikola Šegedin
HHHrvoje Hršak
Hrvoje Hršak
SBSanja Dolanski Babić
Sanja Dolanski Babić
SJSlaven Jurković
Slaven Jurković
Purpose: The purpose of this study is to calculate volume averaging correction factors for detectors used in the dosimetry of Gamma Knife's narrow photon beams, and to determine the impact of volume averaging on the field output correction factor.Methods: Simulations of different Gamma Knife fields were done using elliptical dose model formalism with newly introduced fit functions. To determine volume averaging correction factors a calculation of the absorbed dose over the volume of the detector was performed. The elliptical dose model was tested with respect to absorbed dose distribution for different volumes and compared with the calculations of Leksell GammaPlan v.11.3.1.Results: The largest differences in absorbed dose calculated by the elliptical model and Leksell GammaPlan are 2.25%, 1.5%, and 0.6% for 16, 8, and 4 mm field sizes, respectively. Volume averaging correction factors were determined for six ionization chambers, five semiconductor detectors, a diamond, and two plastic scintillator detectors. In general, for all examined detectors the impact of volume averaging is more pronounced for smaller field sizes. All studied ionization chambers had a larger volume than other detectors, therefore the volume averaging correction factors for ionization chambers are larger for all investigated field sizes. Besides the fact that plastic scintillator detectors can be considered tissue‐equivalent, volume averaging correction factor should be applied.Conclusion: Volume averaging correction factors for different detectors are determined and suitable detectors for dosimetry of Gamma Knife's narrow photon beams are recommended. It is shown that volume averaging has a dominant contribution to a field output correction factor.