Guglielmo Frigo

Dr. Guglielmo Frigo

Laboratory of Electrical Energy and Power, Swiss Federal Institute of Metrology, 3003 Bern, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MBMatteo Bertocco
Matteo Bertocco
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
CNClaudio Narduzzi
Claudio Narduzzi
CMCarlo Muscas
Carlo Muscas
PPPaolo Attilio Pegoraro
Paolo Attilio Pegoraro
Synchrophasor measurements, performed by phasor measurement units (PMUs), are becoming increasingly important for power system network monitoring. Synchrophasor standards define test signals for verification of PMU compliance, and set acceptance limits in each test condition for two performance classes (P and M ). Several PMU algorithms have been proposed to deal with steady-state and dynamic operating conditions identified by the standard. Research and discussion arising from design, implementation, testing and characterization of PMUs evidenced that some disturbances, such as interharmonic interfering signals, can seriously degrade synchrophasor measurement accuracy. In this paper, a new compressive sensing (CS) approach is introduced and applied to synchrophasor measurements using a CS Taylor-Fourier (TF) multifrequency (CSTFM) model. The aim is to exploit, in a joint method, the properties of CS and the TF transform to identify the most relevant components of the signal, even under dynamic conditions, and to model them in the estimation procedure, thus limiting the impact of harmonic and interhamonic interferences. The CSTFM approach is verified using composite tests derived from the test conditions of the synchrophasor standard and simulation results are presented to show its potentialities.

27 March 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
ADAsja Derviskadic
Asja Derviskadic
YZYihui Zuo
Yihui Zuo
MPMario Paolone
Mario Paolone
In modern power systems, the Rate-of-Change-of-Frequency (ROCOF) may be largely employed in Wide Area Monitoring, Protection and Control (WAMPAC) applications. However, a standard approach towards ROCOF measurements is still missing. In this paper, we investigate the feasibility of Phasor Measurement Units (PMUs) deployment in ROCOF-based applications, with a specific focus on Under-Frequency Load-Shedding (UFLS). For this analysis, we select three state-of-the-art window-based synchrophasor estimation algorithms and compare different signal models, ROCOF estimation techniques and window lengths in datasets inspired by real-world acquisitions. In this sense, we are able to carry out a sensitivity analysis of the behavior of a PMU-based UFLS control scheme. Based on the proposed results, PMUs prove to be accurate ROCOF meters, as long as the harmonic and inter-harmonic distortion within the measurement pass-bandwidth is scarce. In the presence of transient events, the synchrophasor model looses its appropriateness as the signal energy spreads over the entire spectrum and cannot be approximated as a sequence of narrow-band components. Finally, we validate the actual feasibility of PMU-based UFLS in a real-time simulated scenario where we compare two different ROCOF estimation techniques with a frequency-based control scheme and we show their impact on the successful grid restoration.

4 January 2011 in Surgical and Radiologic Anatomy
Verified
Journal Article
Closed access
PDF file
LBL. Benetazzo
L. Benetazzo
ABA. Bizzego
A. Bizzego
RCR. De Caro
R. De Caro
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
Diego GuidolinDiego Guidolin
Diego Guidolin
CARLA STECCOCARLA STECCO
CARLA STECCO

30 May 2014 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MBMatteo Bertocco
Matteo Bertocco
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
CNClaudio Narduzzi
Claudio Narduzzi
Federico TramarinFederico Tramarin
Federico Tramarin
Measurement in power systems and, particularly, in smart grids and smart microgrids is often concerned with harmonic analysis of voltage and current waveforms. The use of Fourier-based algorithms is widespread, and the limits following from the fundamental time-versus-frequency tradeoff that relates observation time to frequency resolution are well understood. This paper presents the application of an algorithm based on the principles of compressive sensing that can achieve an order-of-magnitude resolution improvement without significantly extending total observation time. For harmonic analysis in power systems, this means that accurate results can be obtained using shorter observation intervals, which allow to effectively track changes and reduce the effect of transients on measurements. The application of the algorithm to harmonics and interharmonics, as well as to phasor measurement, is considered and analyzed.

13 March 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CNClaudio Narduzzi
Claudio Narduzzi
MBMatteo Bertocco
Matteo Bertocco
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
GGGiada Giorgi
Giada Giorgi
To effectively manage the growing number of distributed energy resources, more extensive monitoring is needed at distribution network levels, where a challenging combination of constraints and cost-effectiveness requirements must be taken into account. In this paper, we consider the idea of combining accurate phasor measurement with the capability to analyze harmonic and interharmonic phasors. This creates the need to deal with multiple phasor components having different amplitudes, including interharmonics with unknown frequency locations. For this purpose, we propose an enhanced compressive sensing-based algorithm for the estimation of Taylor-Fourier coefficients in a multifrequency dynamic phasor model. We characterize its accuracy in harmonic and interharmonic phasor measurement and discuss reporting rate and latency performance. We show that very good accuracy can also be achieved as a standard phasor measurement unit, allowing to combine multiple functions into a promising new-generation measurement, monitoring, and diagnostic device.

20 August 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YZYihui Zuo
Yihui Zuo
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
ADAsja Derviskadic
Asja Derviskadic
MPMario Paolone
Mario Paolone
This paper investigates the impact of synchrophasor estimation algorithms in Under-Frequency Load-Shedding (UFLS) and Load-Restoration (LR) schemes, relying on frequency and Rate-of-Change-of-Frequency (ROCOF) measurements produced by Phasor Measurement Units (PMUs). We compare two consolidated window-based synchrophasor estimation algorithms, as representative approaches based on static and dynamic signal models, with a focus on the appropriateness of utilizing PMU-based ROCOF measurements. The performance of the proposed relaying scheme is assessed by means of a Real-Time Digital Simulator implementing the time-domain full-replica dynamic model of the IEEE 39-Bus power system.