Non-targeted metabolomics is increasingly applied in various applications for understanding biological processes and finding novel biomarkers in living organisms. However, high-confidence identity confirmation of metabolites in complex biological samples is still a significant bottleneck, especially when using single-stage mass analysers. In the current study, a complete workflow for alternating in-source fragmentation on a time-of-flight mass spectrometry (TOFMS) instrument for non-targeted metabolomics is presented. Hydrophilic interaction liquid chromatography (HILIC) was employed to assess polar metabolites in yeast following ESI parameter optimization using experimental design principles, which revealed the key influence of fragmentor voltage for this application. Datasets from alternating in-source fragmentation high resolution mass spectrometry (HRMS) were evaluated using open-source data processing tools combined with public reference mass spectral databases. The significant influence of the selected fragmentor voltages on the abundance of the primary analyte ion of interest and the extent of in-source fragmentation allowed an optimum selection of qualifier fragments for the different metabolites. The new acquisition and evaluation workflow was implemented for the non-targeted analysis of yeast extract samples whereby more than 130 metabolites were putatively annotated with more than 40% considered to be of high confidence. The presented workflow contains a fully elaborated acquisition and evaluation methodology using alternating in-source fragmentor voltages suitable for peak annotation and metabolite identity confirmation for non-targeted metabolomics applications performed on a single-stage HRMS platform.
Waxis one of the compounds that can be misused to be added to Gorengan, Indonesianfritter, to keep them crispy. Gorengan containing waxis difficult to identify visually, so a quick and easy method of detecting wax content is required. The purpose of this research is to develop and evaluate the analytical performance of detectingwax content in gorengan using smartphone. Gorengan sample was dissolved with hexane and then added reagent that will give discolorationfollowed by analysis using smartphone. Some analysis performance parameters were evaluated in terms of linearity and detection limit, qualitative analysis capability, precision, and selectivity test. The developed method was also applied in some gorengansamples. The result shows that the detection of wax content in gorengan can be conducted by using reagent consisting of NaOH, Schift, and curcumin (1: 2: 2). Performance analysis shows that thelinearity measurement atconcentration between 10% and 25% has correlation coefficient (r) of 0.9537 with detection limit at concentration of 2% and precision (%RSD) less than 3%. The developed method can be applied for the detection of wax content ingorengan in the market.
The aim of this work were to develop and validate a visible spectrophotometry for quantitative analysis of pirenoxine in the presence of methylparaben and propylparaben. The proposed method was also applied for real samples of eye drop preparations. The developed method was validated in terms of linearity, range, accuracy, precision, limits of detection (LOD) and limits of quantification (LOQ) by using standard mixture solutions. Method validation was performed according to the United State Pharmacopeia (USP 36) and International Conference on Harmonization Q2(R1) guidelines for the analytical performance parameters. The results of validation illustrated good linearity with the squares of correlation coefficient (r2) greater than 0.99 in the concentration ranges of 2.0-10.0 μg/mL. The method was accurate with average recovery was 100.6%. The relative standard deviation (RSD) of intra-day and inter-day precission were less than 2.00%. LOD and LOQ were found to be 0.40μg/mL and 1.2μg/mL, respectively. The visible spectrophotometric method was found to be precise, accurate, rapid, simple, and inexpensive. The developed and validated method was suitable for quantitation of pirenoxine in real samples of eye drop preparations and could be transferred to quality control laboratories.