Yongjun Lai

Dr. Yongjun Lai

Queen's University, Kingston, Ontario, Canada
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2019 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
ACAngelica Campigotto
Angelica Campigotto
SLStephane Leahy
Stephane Leahy
GZGuowei Zhao
Guowei Zhao
RCRobert J Campbell
Robert J Campbell
Yongjun LaiYongjun Lai
Yongjun Lai
Background Glaucoma is the second leading cause of blindness in the world and the first leading cause of irreversible vision loss. Currently, the primary methodology of testing for the intraocular pressure (IOP) is during clinical office hours, which only provide a limited amount of information on the trends and fluctuations of the IOP. Therefore, a continuous monitoring system is required to properly determine the peaks of pressure and to negate any false results obtained by sparse, clinic hour testing. The objective of this study is to determine the ability of a newly designed contact lens with an embedded microchannel, to accurately measure the fluctuations in the IOP. Methods Experimentation was completed on fresh enucleated porcine eyes. The contact lens was placed on the porcine eye and utilising a camera the fluid movement, within the microchannel in the contact lens, was recorded. A micro-pressure catheter, threaded into the centre of the vitreous chamber, recorded the true IOP and was compared with the displacement of the indicator fluid within the microchannel. Results The contact lenses showed a consistent linear responsiveness to changes in IOP and robust to the effects of anatomical differences among eyes. The indicator fluid had an average fluid movement of 28 um/mm Hg between all the trials. Additionally, the devices showed the ability to measure both increases and decreases in IOP during cyclical fluctuations. Conclusion The described inexpensive and non-invasive sensor is able to reliably monitor the IOP changes based on porcine eye model.

1 February 2019 in MEDICAL DEVICES & SENSORS
Verified
Journal Article
Open access
PDF file
RHRick Helgason
Rick Helgason
ABAmey Banavali
Amey Banavali
Yongjun LaiYongjun Lai
Yongjun Lai
A technique is exploited to develop a dry ECG sensor using polydimethylsiloxane (PDMS) with enhanced adhesion to skin. The sensor consists of silver nanowires (AgNWs) embedded in PDMS. The adhesive solution presented is a novel technique which combines using high‐ratio 25:1 PDMS selectively deposited in a thin layer on the surface of a sensor body that is made from 15:1 PDMS. With this adhesive mechanism, we demonstrate a cohesive ECG sensor which can adhere to a subject without the use of additional sticky adhesives and that is compatible with current ECG technology. PDMS is residue free and highly biocompatible meaning this is a solution suitable for long‐term wear. We demonstrate that our sensor can be filtered to similar quality of a traditional ECG sensor, and further show that our sensors stay in place for more than 24 hr and it can adhere to skin with an average maximum force of about 1.09 N.

22 April 2020 in MEDICAL DEVICES & SENSORS
Verified
Journal Article
Closed access
PDF file
ACAngelica Campigotto
Angelica Campigotto
Yongjun LaiYongjun Lai
Yongjun Lai

1 April 2009 in Sensors
Verified
Journal Article
Open access
PDF file
RSRana Iqtidar Shakoor
Rana Iqtidar Shakoor
SBShafaat Ahmed Bazaz
Shafaat Ahmed Bazaz
Michael KraftMichael Kraft
Michael Kraft
Yongjun LaiYongjun Lai
Yongjun Lai
MHMuhammad Masood Ul Hassan
Muhammad Masood Ul Hassan
High force, large displacement and low voltage consumption are a primary concern for microgyroscopes. The chevron-shaped thermal actuators are unique in terms of high force generation combined with the large displacements at a low operating voltage in comparison with traditional electrostatic actuators. A Nickel based 3-DoF micromachined gyroscope comprising 2-DoF drive mode and 1-DoF sense mode oscillator utilizing the chevron-shaped thermal actuators is presented here. Analytical derivations and finite element simulations are carried out to predict the performance of the proposed device using the thermo-physical properties of electroplated nickel. The device sensitivity is improved by utilizing the dynamical amplification of the oscillation in 2-DoF drive mode using an active-passive mass configuration. A comprehensive theoretical description, dynamics and mechanical design considerations of the proposed gyroscopes model are discussed in detail. Parametric optimization of gyroscope, its prototype modeling and fabrication using MetalMUMPs has also been investigated. Dynamic transient simulation results predicted that the sense mass of the proposed device achieved a drive displacement of 4.1µm when a sinusoidal voltage of 0.5V is applied at 1.77 kHz exhibiting a mechanical sensitivity of 1.7μm /o/s in vacuum. The wide bandwidth frequency response of the 2-DoF drive mode oscillator consists of two resonant peaks and a flat region of 2.11 kHz between the peaks defining the operational frequency region. The sense mode resonant frequency can lie anywhere within this region and therefore the amplitude of the response is insensitive to structural parameter variations, enhancing device robustness against such variations. The proposed device has a size of 2.2 x 2.6 mm2, almost one third in comparison with existing M-DoF vibratory gyroscope with an estimated power consumption of 0.26 Watts. These predicted results illustrate that the chevron-shaped thermal actuator has a large voltage-stroke ratio shifting the paradigm in MEMS gyroscope design from the traditional interdigitated comb drive electrostatic actuator. These actuators have low damping compared to electrostatic comb drive actuators which may result in high quality factor microgyroscopes operating at atmospheric pressure.

16 May 2008 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
PYPeng Yang
Peng Yang
MSMathew Stevenson
Mathew Stevenson
Yongjun LaiYongjun Lai
Yongjun Lai
CMChris Mechefske
Chris Mechefske
MKMarek Kujath
Marek Kujath
THTed Hubbard
Ted Hubbard

1 October 2006 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Open access
Yongjun LaiYongjun Lai
Yongjun Lai
Evgueni BordatchevEvgueni Bordatchev
Evgueni Bordatchev
SNSuwas K. Nikumb
Suwas K. Nikumb
WHWensyang Hsu
Wensyang Hsu
Static and dynamic electro-mechanical performance of a microactuator is a key factor in the functioning of an integrated microsystem composed of moving components such as optical shutters/switches, micropumps, microgrippers, and microvalves. Therefore, the development of such systems primarily focuses on the overall design and parameter optimization of an actuator as the major driving element with respect to the desired performance parameters, e.g., displacement, force, dimensional constraints, material, actuation principle, and method of fabrication. This study presents results on the static and dynamic electro-mechanical performance analysis of an in-plane electro-thermally driven linear microactuator. Each microactuator, having a width of 2220 mm and made of 25 mm thick nickel foil, consisted of a pair of cascaded structures. Connecting several actuation units in a series formed each cascaded structure. Several microactuators with a different number of actuation units were fabricated using the laser micromachining technology. The static performance of these microactuators was evaluated with respect to the maximum linear output displacements, actual resistance, applied current, and consumed electric power. The maximum displacements varied approximately from 3 to 44 mm, respectively, depending on the number of actuation units. The dynamic performance was studied as a response function on constant applied current with respect to the output displacements. In addition, the response time was evaluated for different applied currents and for actuators with 2, 4, and 6 actuation units. The microactuators’ performance results are promising for applications in MEMS/MOEMS, microfluidic, and microrobotic devices.