Series capacitors increase the power transfer limit of transmission lines. However, the protection of series compensated lines using only local measurement is challenging. Phasor based distance protection experiences delay and directional problems in the presence of a series capacitor. This paper presents an incremental quantity based distance protection algorithm for series compensated lines. The algorithm uses instantaneous voltage and current measurements from the local bus. It consists of capacitor voltage estimation, fault detection, phase selection, directional discrimination and distance estimation. The algorithm is extensively tested based on simulations with a line-end series capacitor, considering different source impedance ratios, fault inception angle, compensation levels, and fault resistance, location and type. This time-domain method is shown to work well, with fast decision time.
The introduction of series capacitors in transmission lines causes problems in terms of reliability and the security of distance protection relays. As distance protection is widely used in the transmission network, the challenge of applying it to series compensated lines has been taken up by utilities and relay manufacturers in various ways. In the field of power system protection, developments are largely driven by relay manufacturers, and are often not published in the academic literature; the status and trend of the relay manufacturer’s development are better found in their product manuals and patent activity. Further insight into specific implementations by transmission utilities can be found from publications in industry-led forums and some academic journals. This article surveys the status and development of distance protection for series compensated lines, with a focus on industrial implementation and practical considerations. Factors that influence the protection of series compensated lines are presented. Implementation examples reported by utilities are summarized as examples of the different situations encountered and the methods used to deal with them. It is observed that many utilities use communication-aided protection in series compensated lines, and distance protection is used with reduced reach. Solutions described in relay manuals are presented to demonstrate the manufacturers’ approaches to problems associated with series capacitor protection. While there are methods to counter voltage inversion, current inversion seems to represent a more serious challenge. A patent overview indicates the trends in this domain to be moving towards time-domain-based faster protection methods.
16 September 2024 in IEEE Transactions on Instrumentation and Measurement
The integration of renewable energy sources has significantly impacted power system protection schemes, primarily by increasing short-circuit fault currents, which, in turn, raises the possibility of current transformer (CT) saturation, and by introducing bidirectional fault current flow, which interferes with the directional selectivity of relays in detecting downstream faults. This study presents a novel fault direction identification algorithm aimed at immunization against CT saturation effects, especially in medium voltage (MV) distribution grids integrated with renewable sources. To achieve this, two distinct computational frameworks have been developed and proposed. The first framework utilizes the modified least squares (MLSs) method, while the second employs a modified Kalman filter (MKF). Both algorithms calculate the fundamental current phase angle using a sub-cycle window of current samples, ensuring resilience to heavily distorted waveforms caused by CT saturation, even under conditions of deep saturation. The effectiveness of the proposed method is validated through numerous tests conducted on fault currents recorded via simulation scenarios and field measurements, considering various fault inception times, resistances, and locations, together with different neutral grounding arrangements. Comparative assessments of the two developed frameworks across different scenarios indicate that both methods exhibit promising performances, although the least square-based method demonstrates superior efficiency compared to the Kalman filter-based method.
One imperative challenge in building a sustainable electricity future is to integrate renewable energy sources in the present energy mix. Renewable energy sources are inherently different in nature from their conventional counterparts. Thus integration to existing system posses a substantial challenges. In this paper using a IEEE 14 bus test system the effect of large scale and distributed integration of wind and solar PV on power system stability is assessed using PSAT. Both small signal and transient stability are studied with varying amount of renewable energy in the system. From the simulation results, it is observed that the small signal stability degrades with higher renewable energy penetration, and the transient frequency and voltage response of the system worsens as well with higher renewable energy in the system, but nonetheless the systems in different scenarios remains stable despite having poor damping.