Min-Gu Kim

Dr. Min-Gu Kim

Chosun University
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2019 in Journal of Ambient Intelligence and Humanized Computing
Verified
Journal Article
Open access
PDF file
MKMin-Gu Kim
Min-Gu Kim
HKHoon Ko
Hoon Ko
Sung Bum PanSung Bum Pan
Sung Bum Pan
The risk of tampering exists for conventional user recognition methods based on biometrics such as face and fingerprint. Recently, research on user recognition using biometric signals such as electrocardiogram (ECG), electroencephalogram (EEG), and electromyogram (EMG) has been actively performed to overcome this issue. We herein propose a user recognition method applying a deep learning technique based on ensemble networks after transforming ECG signals into two-dimensional (2D) images. A preprocessing process for one-dimensional ECG signals is performed to remove noise or distortion; subsequently, they are projected onto a 2D image space and transformed into image data. For the proposed algorithm, we designed deep learning-based ensemble networks to improve the degraded performance arising from overfitting in a single network. Our experimental results demonstrate that the proposed ensemble networks exhibit an accuracy that is 1.7% higher than that of the single network. In particular, the performance of the ensemble networks is up to 13% higher compared to the single network that degrades the recognition rate by displaying similar features between classes.

9 April 2019 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
MKMin-Gu Kim
Min-Gu Kim
Sung Bum PanSung Bum Pan
Sung Bum Pan
The postmobile era will go beyond using individual smart devices and allow for user interaction by connecting various devices with sensing capabilities, such as smartphones, wearable devices, automobiles, and the Internet of Things. Wearable devices can continuously collect a variety of information on the users and their environment as the devices are worn in daily life. Because of this, real-time big data analysis technology is needed. This paper proposes a deep learning-based ensemble network model for improving the performance and overcoming the problems, which can occur on a single network. This model is designed so that the features produced by n number of single networks are combined and relearned. In addition, different parameter values are used on each single network, and the data used in the experiments are generated by the fiducial point method, which uses feature point detection, and the nonfiducial point method for periods of 1 sec and n sec. In the experiment results, in the case of fiducial point-based ECG signals, the ensemble network recognition performance shows a maximum of 0.8% higher accuracy than that of the single network. In the case of a 1 sec period nonfiducial point-based ECG signal, the ensemble network recognition performance is a minimum of 0.4% and a maximum of 1% higher than that of the single network. In the case of an n sec period, there is a maximum difference of 1.3%, and the proposed ensemble network shows better performance than the single network.

25 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JKJin Su Kim
Jin Su Kim
MKMin-Gu Kim
Min-Gu Kim
Sung Bum PanSung Bum Pan
Sung Bum Pan
Electromyogram (EMG) signals cannot be forged and have the advantage of being able to change the registered data as they are characterized by the waveform, which varies depending on the gesture. In this paper, a two-step biometrics method was proposed using EMG signals based on a convolutional neural network–long short-term memory (CNN-LSTM) network. After preprocessing of the EMG signals, the time domain features and LSTM network were used to examine whether the gesture matched, and single biometrics was performed if the gesture matched. In single biometrics, EMG signals were converted into a two-dimensional spectrogram, and training and classification were performed through the CNN-LSTM network. Data fusion of the gesture recognition and single biometrics was performed in the form of an AND. The experiment used Ninapro EMG signal data as the proposed two-step biometrics method, and the results showed 83.91% gesture recognition performance and 99.17% single biometrics performance. In addition, the false acceptance rate (FAR) was observed to have been reduced by 64.7% through data fusion.

20 February 2020 in IEEE Access
Verified
Journal Article
Open access
MKMin-Gu Kim
Min-Gu Kim
Chang ChoiChang Choi
Chang Choi
Sung Bum PanSung Bum Pan
Sung Bum Pan
Research on electrocardiogram (ECG) signals has been actively undertaken to assess their value as a next generation user recognition technology, because they require no stimulation and are robust against forgery and modification. However, even within the same user, the heart rate and waveform of ECG signals will vary depending on physical activity, mental effects, and measurement time. Therefore, when data acquired across changes in the user state is used as registered data, an overfitting problem occurs due to data generalization, which degrades the recognition performance for newly acquired data. Therefore, in this paper, we propose parallel ensemble networks to solve the overfitting problem and prevent the degradation. First, ECG signals acquired in various environments are used as the input data of parallel convolutional neural networks (CNNs). Each CNN is set up with different parameters to detect different features. The ECG signals outputted from each network are classified for each subject, and then fused into one database to be used as registered data for re-training. Instead of fusing all the output signals from each network, only the ECG signals of Top-3 networks showing excellent performance are fused and composed of registered data. The reconstructed registered data are used for user recognition, by re-training with time independent comparison data in the CNN. The experimental results of comparing the proposed parallel ensemble networks with those of previous studies using the self-acquired actual ECG signals show that the proposed method achieves recognition performance higher than the previous studies, with an accuracy rate of 98.5%.

8 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MKMin-Gu Kim
Min-Gu Kim
Sung Bum PanSung Bum Pan
Sung Bum Pan
Electrocardiogram (ECG) signals are time series data that are acquired by time change. A problem with these signals is that comparison data that have the same size as the registration data must be acquired every time. A network model of an auxiliary classifier based generative adversarial neural network that is capable of generating synthetic ECG signals is proposed to resolve the data size inconsistency problem. After constructing comparison data with various combinations of the real and generated synthetic ECG signal cycles, a user recognition experiment was performed by applying them to an ensemble network of parallel structure. Recognition performance of 98.5% was demonstrated when five cycles of real ECG signals were used. Moreover, 98.7% and 97% accuracies were provided when the first cycle of synthetic ECG signals and the fourth cycle of real ECG signals were repetitively used as the last cycle, respectively, in addition to the four cycles of real ECG. When two cycles of synthetic ECG signals were used with three cycles of real ECG signals, 97.2% accuracy was shown. When the last third cycle was repeatedly used with the three cycles of real ECG signals, the accuracy was 96%, which was 1.2% lower than the performance obtained while using the synthetic ECG. Therefore, even if the size of the registration data and that of the comparison data are not consistent, the generated synthetic ECG signals can be applied to a real life environment, because a high recognition performance is demonstrated when they are applied to an ensemble network of parallel structure.

20 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JKJAE MYUNG KIM
JAE MYUNG KIM
MKMin-Gu Kim
Min-Gu Kim
Sung Bum PanSung Bum Pan
Sung Bum Pan
With the spread of the modern media industry, harmful genre contents are indiscriminately disseminated to teenagers. The password identification method used to block sensational and violent genre content has become a problem that teenagers can easily steal. Therefore, a user identification method with less risk of theft and hacking is required. The surface EMG (sEMG) signal, which is an electrical signal generated inside the body and has individual features, is being studied as a next-generation user identification method. sEMG involves measuring an individual’s unique muscular strength activated over time as digital signals, thus giving it the advantage of generating different signal patterns. However, it is difficult to constantly and repeatedly acquire each motion signal and the number of repetitions for each motion is insufficient, thus there is a limit to improving user identification accuracy. In this paper, we propose a user identification system that solves the problem of insufficient data by applying the matching pursuit that enables signal generation to the sEMG signal from which the resting signal has been removed and improves classification accuracy by extracting STFT-based time–frequency features. As a result of the experiment, the user identification accuracy of the sEMG spectrogram with the resting state signal removed was 85.4%. In addition, when the training data were increased through data generation, the accuracy was improved, showing a user identification accuracy of 96.1%. Improved user recognition accuracy was confirmed when the training data of the sEMG signal from which the resting signal was removed were increased and multidimensional features including time–frequency were used.