Wenjie Lv

Dr. Wenjie Lv

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
WLWenjie Lv
Wenjie Lv
WHWangdong He
Wangdong He
XLXipeng Lin
Xipeng Lin
JMJungang Miao
Jungang Miao
A non-contact heartbeat/respiratory rate monitoring system was designed using narrow beam millimeter wave radar. Equipped with a special low sidelobe and small-sized antenna lens at the front end of the receiving and transmitting antennas in the 120 GHz band of frequency-modulated continuous-wave (FMCW) system, this sensor system realizes the narrow beam control of radar, reduces the interference caused by the reflection of other objects in the measurement background, improves the signal-to-clutter ratio (SCR) of the intermediate frequency signal (IF), and reduces the complexity of the subsequent signal processing. In order to solve the problem that the accuracy of heart rate is easy to be interfered with by respiratory harmonics, an adaptive notch filter was applied to filter respiratory harmonics. Meanwhile, the heart rate obtained by fast Fourier transform (FFT) was modified by using the ratio of adjacent elements, which helped to improve the accuracy of heart rate detection. The experimental results show that when the monitoring system is 1 m away from the human body, the probability of respiratory rate detection error within ±2 times for eight volunteers can reach 90.48%, and the detection accuracy of the heart rate can reach 90.54%. Finally, short-term heart rate measurement was realized by means of improved empirical mode decomposition and fast independent component analysis algorithm.

1 December 2016 in BMC Biochemistry
Verified
Journal Article
Open access
PDF file
WZWenjie Zhang
Wenjie Zhang
LCLei Chen
Lei Chen
HXHonggang Xiang
Honggang Xiang
CHChunhua Hu
Chunhua Hu
WSWeibin Shi
Weibin Shi
WLWenjie Lv
Wenjie Lv
Gamma glutamylcyclotransferase (GGCT) has been proved to be involved in various cancers, but the biological function of GGCT in gastric cancer is still largely unknown. The expression level of GGCT was evaluated by informatics analyses based on the Oncomine database. GGCT gene was then effectively knocked down via lentivirus mediated short hairpin RNA (shRNA) system. Then a series of functional assays, including MTT, colony formation and flow cytometry analysis were conducted on gastric cancer cells following GGCT knockdown. We found GGCT is commonly up-regulated in gastric cancer tissues. Furthermore, MTT analysis showed that GGCT depletion significantly inhibited cell proliferation in MGC80-3 and AGS cells. Colony formation assay revealed that depletion of GGCT reduced the colony formation ability in gastric cancer cells. What’s more, cell cycle analysis showed that depletion of GGCT induced gastric cancer cell cycle arrested G2/M phase. More importantly, cell apoptosis analysis further revealed that GGCT inhibition induced early and late cell apoptosis in gastric cancer. This study suggests GGCT is essential for gastric cancer proliferation and its downregulation may provide a potential anticancer therapy for gastric cancer.

10 December 2021 in IEEE Access
Verified
Journal Article
Open access
WLWenjie Lv
Wenjie Lv
Yan ZhaoYan Zhao
Yan Zhao
WZWei Zhang
Wei Zhang
WLWenqi Liu
Wenqi Liu
AHAnyong Hu
Anyong Hu
JMJungang Miao
Jungang Miao
Heart rate measurement technology based on Doppler radar can monitor heart rate in real time without direct contact with the skin, which possesses the advantages of convenient operation, comfort and insensitivity to the skin state. However, due to the limitation of radar’s performance, heartbeat signals obtained by radar sensor do not have clear peak value like electrocardiograms (ECGs) and pulse waves, which affects its measurement accuracy. Therefore, this paper proposes a non-contact short-term heart rate detection system based on 120 GHz narrow beam frequency-modulated continuous-wave (FMCW) millimeter wave radar. On the basis of improving the signal-to-clutter ratio (SCR) of intermediate frequency (IF) signals with narrow beam, this system applies stochastic resonance algorithm to enhance the amplitude of heartbeat signals submerged in radar system noise, thus enhancing the signal-to-noise ratio (SNR) of heartbeat signals and improving the accuracy of heart rate detection. The short-term heart rate of 10 volunteers is measured at 3 s interval under the condition that the radar sensor was 1 m from the human chest. Experimental results show that compared with the peak count of the reference pulse wave sensor, the results of this system are highly consistent with those of photoplethysmograph (PPG) detection. Finally, those results of heart rate detection are also used to analyze heart rate variability (HRV).

31 July 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WLWenjie Lv
Wenjie Lv
CLChang Liu
Chang Liu
HLHaoqiang Liu
Haoqiang Liu
SZShan Zhong
Shan Zhong
HYHao Yang
Hao Yang
SHAOHAN FENGSHAOHAN FENG
SHAOHAN FENG
Heart rate measurement based on radar is an effective method for non-contact monitoring of human vital signs. However, the heart rate signal obtained from the radar is subject to noise interference due to the imperfect circuit characteristics. To tackle this challenge in heart rate detection by micro-Doppler radar, this paper employs a narrow-beam radar operating in the 120 GHz band to capture the heartbeat signal and adopts an intelligent singular value decomposition algorithm to effectively eliminate the noise in the heartbeat signal. This approach can adaptively select the number of large singular values corresponding to the best noise reduction effect under different signal-to-noise ratios. In addition, an improved automatic multi-scale peak detection algorithm is proposed for precise peak detection in the heartbeat signal. Experimental results demonstrate that the proposed algorithm significantly reduces omission or misjudgment during the peak detection process, leading to a high accuracy during short-term heart rate detection. Compared with the pulse wave measurement results, the average accuracy of the heart rate is between 96.53% and 98.18%.