Developing a high-performance capacitive sensor for diverse application scenarios has posed requirements for the sensor to have high sensitivity, broad detection range, and cost-effectiveness. In this experiment, a flexible pressure sensor with a high sensitivity of 2.08 kPa−1 at pressure lower than 1 kPa, as well as a wide working range of 0–600 kPa and remarkable stability (for at least 4000 cycles), was designed. In the device structure, silver nanowires (Ag NWs)/MXene-composite-coated polydimethylsiloxane (PDMS) and natural bamboo leaves at different growth stages were used as the electrode and the micro-structured dielectric layers, respectively. The rough surface of the composite conductive materials and the hierarchical microstructure of the bamboo leaves ensured a high sensitivity and broad pressure range of the sandwich-structured sensor, and the different sizes of the microstructures yielded adjustable sensitivity of the sensor. Furthermore, the outstanding performance of the proposed device made it possible to detect the actual object load, human physical stimuli, and proximity distance, demonstrating applications of flexible and wearable devices in various fields, such as weight/force tapping, breath/wrist pulse/speech, joint bending, and approach distance.
A PAA/Starch/MXene organohydrogel was developed for strain sensors with remarkable sensitivity, offering potential for widespread applications in wearable electronics.
Highlights The problems of high resistance to seed sucking and the poor stability of seed sucking were solved. A mechanical model was established for seeds in a seed stirring device. The optimum parameters of the seed stirring device were obtained. Seeding precision was improved, providing a reference for the seed sucking process. Abstract. To achieve a goal of precision seeding with 1 to 3 seeds per hill and to solve problems in a pneumatic rice seed metering device, including high resistance to seed sucking, poor stability of seed suction, and low seeding precision, a cylindrical seed stirring device was designed. The design was based on the characteristics of the rice seed flow in the seed suction area. A mechanical model of the rice seed in the seed stirring device was established. The relationships between the seed fluidity and the parameters of the seed stirring device were simulated with EDEM software. The effects of seed fluidity on the seed suction area were analyzed under different seed stirring device parameters. To analyze the influences of different parameters of the seed stirring device on seed stirring and to observe the relationships between different parameters and rice seeds, high-speed photography was used to observe the seed sucking and stirring processes. The super hybrid rice Y-2 You 900 was selected as the test material. The seeding precision was tested at different rotating speeds, negative pressures, and parameters of the seed stirring device. The test results showed that an increase in the diameter and thickness of the seed stirring device was beneficial for increasing the seed absorption rate and reducing the missed seed rate but also increased the rate of multiple-seed sucking and reduced the seeding precision. The optimal parameters of the seed stirring device were a cylinder thickness of 2 mm and a diameter of 5 mm. This study provides a certain reference basis for the seed suction process of a pneumatic seed metering device. Keywords: Agricultural machinery, Precision seeding, Rice sowing, Seed stirring device, Seeder.
17 June 2025 in ACS Applied Materials & Interfaces