This project focused on improving mobility for a blind person by creating an obstacle and pit detecting walking stick using ultrasonic sensors. The project comprised of both hardware and software. The hardware consists of ultrasonic sensors, buzzers and a microcontroller, while the software consists of Arduino Integrated Development Environment (Arduino IDE), which was used to program the microcontroller. A Polyvinyl Chloride (PVC) casing was used to house the hardware components. The ultrasonic sensor that detects obstacles was programmed to detect obstacles at a distance of 100 cm or below and causes the buzzer to sound so as to alert the blind person. Another ultrasonic sensor was programmed to identify pit at a depression of 18 cm and above. This stick was tested to detect obstacles by 80 different blindfolded individuals within a room with different objects placed at different positions. Results showed that the percentage reduction of collision rate when comparing the developed ultrasonic walking stick to a normal white cane is 90.1%. This shows that the ultrasonic walking stick is reliable for domestic use by a blind person. Keywords— Arduino, ATmega328 Microcontroller, Blind walking stick, Mobility aid, Smart cane, Ultrasonic sensor.
1 October 2023 in 3D Printing and Additive Manufacturing
Fused deposition modeling has provided a cheap and effective method for the rapid production of prototypes and functional products in many spheres of life. In this study, three-dimensional (3D) printing techniques to produce and optimize a hip protector that will assure clinical efficacy are presented. The I-Optimal design was used to optimize the hip protector's significant parameters (infill density, shell thickness, and material shore hardness) to obtain maximum femoral neck force attenuation of the 3D-printed hip protector. A drop impact tower device simulates the impact force at the hip's parasagittal plane during a fall. The results show that the infill density has the most significant influence on attenuation properties, followed by the infill density combined with the material shore hardness. By maximizing all the parameters, it is demonstrated that using an additive manufacturing technique to print hip protectors could be an effective strategy in curbing hip fractures.
An innovative 3D printed hip protector has been designed and tested to decrease the possibility of hip fracture in a sideways fall to a hard surface. The main design purpose was to create custom fit hip protector, reduce the manufacturing period and make the protector comfortable to wear. This work compares the new energy shunting 3D printed hip protector design with an existing energy absorbing hip protector. A drop tower mechanical test rig was designed and developed to simulate a sideways fall with sufficient impact energy to fracture an unprotected greater trochanter (GT). The test rig incorporates the actual geometry of a femur made from steel and uses a foam to simulate trochanteric soft tissue over the greater trochanter. Similar impact energy was used for the testing of each hip protector. The weight of the striker mass was maintained, and the height was adjusted to obtain an impact energy of 21–43J to produce femoral neck force of 3–9 kN. Results illustrate that the 3D hip protector compares favorably in attenuating impact force capable of causing hip fracture to a value below the fracture threshold of 3.472 kN. The influence of the 3D hip protector on peak transmitted forces to the vulnerable site of the greater trochanter is shown to be positive. It is anticipated that future protectors can be 3D printed after optimizations to end the bundling of same hip protector for different body geometry.
31 March 2019 in FUOYE Journal of Engineering and Technology
The research aimed at evaluating the effect of set-up height on the performance of earthenware pot-in-pot cooling system. The pots were set up at different heights; H1 (0 m), H2 (0.5 m) and H3 (1 m) and observed for 59 days from 8:00am to 6:00pm daily. The inner temperatures obtained from the three different arrangements were determined using standard methods. The result showed that increasing the height from ground level (0 m) to 1 m increases the mean cooling effect by 8 %. Generally, it was observed that only the set-up height at 1 m proved to have maximum efficiency of the pot-in-pot system performance. Keywords— Cooler, Efficiency, Evaporative cooling, Set-up height, Pot-in-pot, Preservation