Francesco Faita

Dr. Francesco Faita

Institute of Clinical Physiology (IFC), Italian National Research Council (CNR), Pisa 56124, Italy
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
Maria Grazia AndreassiMaria Grazia Andreassi
Maria Grazia Andreassi
EPEmanuela Piccaluga
Emanuela Piccaluga
LGLuna Gargani
Luna Gargani
LSLaura Sabatino
Laura Sabatino
Andrea BorghiniAndrea Borghini
Andrea Borghini
EPEugenio Picano
Eugenio Picano

1 July 2012 in Journal Of Hypertension
Verified
Journal Article
Closed access
LGLorenzo Ghiadoni
Lorenzo Ghiadoni
Francesco FaitaFrancesco Faita
Francesco Faita
MSMassimo Salvetti
Massimo Salvetti
CCCarlo Cordiano
Carlo Cordiano
ABAlmerina Biggi
Almerina Biggi
FCFrancesco Cosentino
Francesco Cosentino
Impaired flow-mediated dilation (FMD) is associated with cardiovascular risk factors and provides prognostic information. Despite the noninvasive nature of this technique, a major limitation to its widespread use is low reproducibility. The aim of this study was to evaluate impact of methodological standardization among different investigation sites on brachial artery FMD reproducibility. Seven Italian centers recruited 135 healthy volunteers, aged 20-60 years. FMD was assessed by high-resolution ultrasound equipped with a stereotactic probe-holding device. Certified sonographers recorded brachial artery scans at baseline (day 1a), 1 h after (day 1b), and 1 month later (day 30). Endothelium-independent vasodilation (EIVD) to sublingual glyceril-trinitrate was recorded at day 1 and day 30. FMD and EIVD were blindly evaluated at the coordinating center by an automated edge detection system. The intra-session (day 1a versus 1b) and inter-session (day 1a versus 30) coefficients of variation were calculated. FMD was not significantly (P = 0.91) different at day 1a, day 1b and day 30 (6.52 ± 2.9, 6.42 ± 3.1, 6.57 ± 2.8%, respectively). The FMD intra-session coefficient of variation was 9.9 ± 8.4% (from 7.6 to 11.9% across centers). The FMD inter-session coefficient of variation was 12.9 ± 11.6% (from 11.6 to 16.1% across centers). Inter-session coefficient of variation for EIDV was 19.7 ± 16.8%. This study shows a homogeneous coefficient of variation for FMD among different centers. The inter-session coefficient of variation was similar to the intra-session coefficient of variation, representing the intrinsic FMD variability. We demonstrate for the first time that rigorous and standardized procedure may provide reproducible FMD assessment to study endothelial function in multicenter clinical trials.

26 February 2007 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
VGVincenzo Gemignani
Vincenzo Gemignani
Francesco FaitaFrancesco Faita
Francesco Faita
LGLorenzo Ghiadoni
Lorenzo Ghiadoni
EPElisa Poggianti
Elisa Poggianti
MDMarcello Demi
Marcello Demi
The measurement of the brachial artery diameter is frequently used in clinical studies for evaluating the flow-mediated dilation and, in conjunction with the blood pressure value, for assessing arterial stiffness. This paper presents a system for computing the brachial artery diameter in real-time by analyzing B-mode ultrasound images. The method is based on a robust edge detection algorithm which is used to automatically locate the two walls of the vessel. The measure of the diameter is obtained with subpixel precision and with a temporal resolution of 25 samples/s, so that the small dilations induced by the cardiac cycle can also be retrieved. The algorithm is implemented on a standalone video processing board which acquires the analog video signal from the ultrasound equipment. Results are shown in real-time on a graphical user interface. The system was tested both on synthetic ultrasound images and in clinical studies of flow-mediated dilation. Accuracy, robustness, and intra/inter observer variability of the method were evaluated

1 September 2008 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
Francesco FaitaFrancesco Faita
Francesco Faita
VGVincenzo Gemignani
Vincenzo Gemignani
EBElisabetta Bianchini
Elisabetta Bianchini
CGChiara Giannarelli
Chiara Giannarelli
LGLorenzo Ghiadoni
Lorenzo Ghiadoni
MDMarcello Demi
Marcello Demi
Objective. The purpose of this report is to describe an automatic real‐time system for evaluation of the carotid intima‐media thickness (CIMT) characterized by 3 main features: minimal interobserver and intraobserver variability, real‐time capabilities, and great robustness against noise. Methods. One hundred fifty carotid B‐mode ultrasound images were used to validate the system. Two skilled operators were involved in the analysis. Agreement with the gold standard, defined as the mean of 2 manual measurements of a skilled operator, and the interobserver and intraobserver variability were quantitatively evaluated by regression analysis and Bland‐Altman statistics. Results. The automatic measure of the CIMT showed a mean bias ± SD of 0.001 ± 0.035 mm toward the manual measurement. The intraobserver variability, evaluated with Bland‐Altman plots, showed a bias that was not significantly different from 0, whereas the SD of the differences was greater in the manual analysis (0.038 mm) than in the automatic analysis (0.006 mm). For interobserver variability, the automatic measurement had a bias that was not significantly different from 0, with a satisfactory SD of the differences (0.01 mm), whereas in the manual measurement, a little bias was present (0.012 mm), and the SD of the differences was noticeably greater (0.044 mm). Conclusions. The CIMT has been accepted as a noninvasive marker of early vascular alteration. At present, the manual approach is largely used to estimate CIMT values. However, that method is highly operator dependent and time‐consuming. For these reasons, we developed a new system for the CIMT measurement that conjugates precision with real‐time analysis, thus providing considerable advantages in clinical practice.

21 April 2008 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
TBTonino Bombardini
Tonino Bombardini
VGVincenzo Gemignani
Vincenzo Gemignani
EBElisabetta Bianchini
Elisabetta Bianchini
LVLucia Venneri
Lucia Venneri
CPChristina Petersen
Christina Petersen
EPEugenio Picano
Eugenio Picano
A cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been recently validated. Second heart sound can be simultaneously recorded in order to quantify both systole and diastole duration.