Eva Marguí

Dr. Eva Marguí

Department of Chemistry, University of Girona, C/M.Aurlèia Capmany 69, 17003 Girona, Spain
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 May 2022 in Chemosphere
Verified
Journal Article
Open access
EMEva Marguí
Eva Marguí
IQI. Queralt
I. Queralt
EAE. de Almeida
E. de Almeida
In recent years, the conceptual advancement on green analytical chemistry (GAC) has moved in parallel with efforts to incorporate new screening or quantitative low-cost analytical tools to solve analytical problems. In this sense, the role of solid state techniques that allow the non-invasive analysis (or with a minimum sample treatment) of solid samples cannot be neglected. This review describes the basic principles, instrumentation and advances in the application of X-ray fluorescence instrumentation to the environmental sciences research topics, published between 2006 and 2020. Obviously, and because of the enormous number of works that can be found in the literature, it is not possible to exhaustively cover all published articles and the diversity of topics related to the environment in which a solid state technique like XRF has been applied successfully. It is a question of making a compilation of the instrumentation in use, the significant advances in XRF spectrometry and sample treatment strategies to highlight the potential of its implementation for environmental assessment.

1 March 2009 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
EMEva Marguí
Eva Marguí
Ignasi QueraltIgnasi Queralt
Ignasi Queralt
MHManuela Hidalgo
Manuela Hidalgo

1 November 2013 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
CPChris Parsons
Chris Parsons
EMEva Marguí
Eva Marguí
EPEric Pili
Eric Pili
GFGeerke H. Floor
Geerke H. Floor
GRGabriela Roman-Ross
Gabriela Roman-Ross
LCLaurent Charlet
Laurent Charlet

1 January 2014 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
EMEva Marguí
Eva Marguí
BZB. Zawisza
B. Zawisza
RSR. Sitko
R. Sitko

14 March 2013 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
KKKarina Kocot
Karina Kocot
BZBeata Zawisza
Beata Zawisza
EMEva Marguí
Eva Marguí
Ignasi QueraltIgnasi Queralt
Ignasi Queralt
MHManuela Hidalgo
Manuela Hidalgo
RSRafal Sitko
Rafal Sitko
In this paper the combination of dispersive micro solid-phase extraction (DMSPE), using multiwalled carbon nanotubes (MWCNTs) as solid sorbents, with total-reflection X-ray fluorescence spectrometry (TXRF) is proposed for preconcentration and determination of lead and cadmium ions in water samples. The proposed sample preparation is quite simple and economic. After the sorption processes of the metals on the MWCNTs, the aqueous sample is separated by centrifugation and the metal loaded MWCNTs are suspended using a small volume of an internal standard solution and analyzed directly by TXRF. Parameters affecting the extraction process (complexing agent, pH of the aqueous sample, amount of MWCNTs) and TXRF analysis (volume of the deposited suspension on the reflector, drying mode, and instrumental parameters) have been carefully evaluated to test the real capability of the developed methodology for the determination of Cd and Pb at trace levels. For both elements the linear range is observed up to 50 ng mL−1. Under optimized conditions detection limits are 1.0 ng mL−1 and 2.1 ng mL−1 for Cd(II) and Pb(II) ions, respectively. Both of the examined elements can be determined with quantitative recoveries (ca. 100%) and with an adequate precision (RSD = 6.0% and 10.5% for Cd(II) and Pb(II), respectively). Our results give insight into the possibilities of the combination of DMSPE and TXRF for trace metal determination in different types of environmental waters (sea, river and waste water).