Design considerations for magnetorheological (MR) brakes are discussed for different geometries. A complete modeling in terms of torque density, efficiency, bandwidth, and controllability is presented. The model assigns a desired magnetic flux density over the fluid surface. The magnetic circuit dimensions and the necessary power can be calculated in consequence. The analysis focuses on a single disc and on a single drum brake and highlights the interdependence of the measures of performance as a function of the dimensions. The proposed models have been validated using finite-element analysis, the results demonstrate that both brakes are equivalent in terms of torque density but drum brakes are more reactive and require less power. The analysis has subsequently been extended to multiple-layered brakes with several fluid gaps in parallel. The performance are globally improved by increasing the number of gaps. Finally, the paper considers the influence of the MR fluid characteristics and housing material.
11 February 2016 in IEEE Robotics and Automation Letters
In percutaneous needle insertions, cutting forces at the needle tip deflect the needle and increases targeting error. Thus, modeling needle-tissue interaction in biological tissue is essential for accurate robotics-assisted needle steering. In this letter, dynamics of needle tip interaction with inhomogeneous biological tissue is described and the effects of insertion velocity, tissue mechanical characteristics, and needle geometry on tissue cutting force are studied. Needle interaction with biological tissue is divided into three distinct events and modeled. 1) Initial tissue puncturing, which starts by soft tissue deformation and continues until a crack is formed in the tissue. Employing a viscoelastic model of fracture initiation we have predicted the maximum puncturing force and force-displacement response of a needle in contact with a tissue. 2) Tissue cutting, which follows the crack propagation in tissue and is predicted using a novel energy-based fracture model. The model takes account of the needle tip geometry and the tissue mechanical characteristics. 3) Friction between tissue and needle shaft is estimated during needle insertion and retraction using a needle-tissue friction model. Using a needle driving robot ex vivo experiments are performed on a porcine tissue sample to identify the model parameters and validate the analytical predictions offered by the models.
31 March 2016 in IEEE/ASME Transactions on Mechatronics
Robotics-assisted needle steering can enhance targeting accuracy in percutaneous interventions. This paper presents a novel dynamical model for robotically controlled needle steering. This is the first model that predicts both needle shape and tip position in soft tissue, and accepts needle insertion velocity, needle 180° axial rotation, and needle base force/torque as inputs. A hybrid formulation of needle steering dynamics in soft tissue is presented, which considers the needle as a two-body rigid/flexible coupled system composed of a moving, discrete, and rigid part attached to a vibrating compliant part that is subject to external excitation forces. The former is the carrier representing the surgeon's hand or the needle inserting robot, while the latter is a beam modeling the continuous deflection of the needle inside tissue. A novel time-delayed tissue model and a fracture mechanics-based model are developed to model the tissue reaction forces and cutting force at the needle tip, respectively. Experiments are performed on synthetic and ex vivo animal tissues to identify the model parameters and validate the needle steering model. The maximum error of the 2-D model in predicting the needle tip position in the insertion plane was 1.59 mm in the case of no axial rotation and 0.74 mm with axial rotation.
In needle-based medical procedures, beveled-tip flexible needles are steered inside soft tissue with the aim of reaching pre-defined target locations. The efficiency of needle-based interventions depends on accurate control of the needle tip. This paper presents a comprehensive mechanics-based model for simulation of planar needle insertion in soft tissue. The proposed model for needle deflection is based on beam theory, works in real-time, and accepts the insertion velocity as an input that can later be used as a control command for needle steering. The model takes into account the effects of tissue deformation, needle-tissue friction, tissue cutting force, and needle bevel angle on needle deflection. Using a robot that inserts a flexible needle into a phantom tissue, various experiments are conducted to separately identify different subsets of the model parameters. The validity of the proposed model is verified by comparing the simulation results to the empirical data. The results demonstrate the accuracy of the proposed model in predicting the needle tip deflection for different insertion velocities.