Over the past decade, superhydrophilic zwitterionic surfaces, slippery liquid-infused porous surfaces, covalently attached liquid-like surfaces, and superhydrophobic surfaces have emerged as the most promising strategies to prevent biofouling on biomedical devices. Despite working through different mechanisms, they have demonstrated superior efficacy in preventing the adhesion of biomolecules (e.g., proteins and bacteria) compared with conventional material surfaces. However, their potential in combating catheter-associated urinary tract infection (CAUTI) remains uncertain. In this research, we present the fabrication of these four coatings for urinary catheters and conduct a comparative assessment of their antifouling properties through a stepwise approach. Notably, the superhydrophilic zwitterionic coating demonstrated the highest antifouling activity, reducing 72.3% of fibrinogen deposition and over 75% of bacterial adhesion (Escherichia coli and Staphylococcus aureus) when compared with an uncoated polyvinyl chloride (PVC) surface. The zwitterionic coating also exhibited robust repellence against blood and improved surface lubricity, decreasing the dynamic coefficient of friction from 0.63 to 0.35 as compared with the PVC surface. Despite the fact that the superhydrophilic zwitterionic and hydrophobic liquid-like surfaces showed great promise in retarding crystalline biofilm formation in the presence of Proteus mirabilis, it is worth noting that their long-term antifouling efficacy may be compromised by the proliferation and migration of colonized bacteria as they are unable to kill them or inhibit their swarming. These findings underscore both the potential and limitations of these ultralow fouling materials as urinary catheter coatings for preventing CAUTI.
Pin-tract infections (PTIs) are a common complication of external fixation of fractures and current strategies for preventing PTIs have proven to be ineffective. Recent advances show that the use of anti-infection coatings with local antibacterial activity may solve this problem. Selenium has been considered as a promising anti-infection agent owing to its antibacterial and antibiofilm activities. In this study, selenium nanoparticles (SeNPs) were synthesized via a cost-effective fungi-mediated biorecovery approach and demonstrated excellent stability and homogeneity. To investigate their anti-infection potential, the SeNPs were doped in silver coatings through an electroless plating process and the silver–selenium (Ag–Se) coatings were tested for antibacterial and antibiofilm properties against Staphylococcus aureus F1557 and Escherichia coli WT F1693 as well as corrosion resistance in simulated body fluid. It was found that the Ag–Se coating significantly inhibited S.aureus growth and biofilm formation on the surface, reducing 81.2% and 59.7% of viable bacterial adhesion when compared with Ag and Ag–PTFE-coated surfaces after 3 days. The Ag–Se coating also exhibited improved corrosion resistance compared with the Ag coating, leading to a controlled release of Ag+, which in turn reduced the risk of cytotoxicity against hFOBs. These results suggest that the fungal-derived SeNPs may have potential in use as implant coatings to prevent PTIs.
Catheter-associated urinary tract infections (CAUTIs) are among the leading nosocomial infections in the world and have led to the extensive study of various strategies to prevent infection. However, despite an abundance of anti-infection materials having been studied over the last forty-five years, only a few types have come into clinical use, providing an insignificant reduction in CAUTIs. In recent decades, marine resources have emerged as an unexplored area of opportunity offering huge potential in discovering novel bioactive materials to combat human diseases. Some of these materials, such as antimicrobial compounds and biosurfactants synthesized by marine microorganisms, exhibit potent antimicrobial, antiadhesive and antibiofilm activity against a broad spectrum of uropathogens (including multidrug-resistant pathogens) that could be potentially used in urinary catheters to eradicate CAUTIs. This paper summarizes information on the most relevant materials that have been obtained from marine-derived microorganisms over the last decade and discusses their potential as new agents against CAUTIs, providing a prospective proposal for researchers.
27 September 2024 in Colloids and Surfaces B: Biointerfaces
Catheter-associated urinary tract infection (CAUTI) remains an unsolved challenge to date, particularly with the emergence and rapid spread of antimicrobial-resistant bacterial pathogens. Despite extensive research, a catheter coating that can offer intrinsic resistance to host protein deposition, bacterial biofilm formation, and swarming is still urgently required. Zwitterionic hydrogel coatings due to their superior lubricity and antifouling properties represent a promising candidate, but their weak mechanical stability in water and poor resistance to bacterial swarming migration limit their application in urinary catheters for infection control. In this research, we describe the fabrication of a multifunctional catheter coating by copolymerizing zwitterionic sulfobetaine methacrylate (SBMA) polymers and a swarming inhibitor material, 2-hydroxy-3-phenoxypropyl acrylate (HPA). The introduction of polyHPA (PHPA) effectively impeded the uncontrolled swelling behavior of the zwitterionic PSBMA hydrogel, resulting in enhanced mechanical stability. Moreover, the copolymer coating retains the antifouling and anti-swarming properties of the homopolymers when challenged with fibrinogen, Escherichia coli, and Proteus mirabilis. The HPA content significantly correlated with its anti-adhesion activity against fibrinogen and biofilm, and the coating with an SBMA: HPA monomer feed molar ratio of 4:1 showed the best antifouling activity, reducing fibrinogen deposition by about 40 % and biofilm coverage by around fourfold compared to the uncoated polydimethylsiloxane (PDMS) surface. Furthermore, the copolymer coating also exhibited no cytotoxicity, suggesting it as a promising catheter coating for preventing CAUTI.