Wassa Waiwinya

Ms. Wassa Waiwinya

Chulalongkorn University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
PBPoramin Boonbanjong
Poramin Boonbanjong
KTKiatnida Treerattrakoon
Kiatnida Treerattrakoon
WWWassa Waiwinya
Wassa Waiwinya
PPPiyawat PITIKULTHAM
Piyawat PITIKULTHAM
DJDeanpen Japrung
Deanpen Japrung
Isothermal amplification (IA) is a nucleic acid amplification technology (NAAT) that has contributed significantly to the healthcare system. The combination of NAAT with a suitable detection platform resulted in higher sensitivity, specificity, and rapid disease diagnosis. Traditional NAAT, such as polymerase chain reaction (PCR), is widely applied in the general healthcare system but is rarely accessed in resource-limited hospitals. Some IA methods provide a rapid, sensitive, specific, and simple method for disease diagnosis. However, not all IA techniques have been regularly used in clinical applications because different biomarkers and sample types affect either the enzyme in the IA system or sample preparation. This review focuses on the application of some IA techniques that have been applied in the medical field and have the potential for use at points of care.

17 March 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
WWWassa Waiwinya
Wassa Waiwinya
TPThitirat Putnin
Thitirat Putnin
DPDechnarong Pimalai
Dechnarong Pimalai
WCWireeya Chawjiraphan
Wireeya Chawjiraphan
NSNuankanya Sathirapongsasuti
Nuankanya Sathirapongsasuti
DJDeanpen Japrung
Deanpen Japrung
An immobilization-free electrochemical sensor coupled with a graphene oxide (GO)-based aptasensor was developed for glycated human serum albumin (GHSA) detection. The concentration of GHSA was monitored by measuring the electrochemical response of free GO and aptamer-bound GO in the presence of glycated albumin; their currents served as the analytical signals. The electrochemical aptasensor exhibited good performance with a base-10 logarithmic scale. The calibration curve was achieved in the range of 0.01–50 µg/mL. The limit of detection (LOD) was 8.70 ng/mL. The developed method was considered a one-drop measurement process because a fabrication step and the probe-immobilization process were not required. This simple sensor offers a cost-effective, rapid, and sensitive detection method, and could be an alternative approach for determination of GHSA levels.