Hendrik Walther

Dr. Hendrik Walther

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in Optometry and Vision Science
Verified
Journal Article
Closed access
HWHendrik Walther
Hendrik Walther
HLHolly Lorentz
Holly Lorentz
MHMiriam Heynen
Miriam Heynen
LKLise Kay
Lise Kay
Lyndon JonesLyndon Jones
Lyndon Jones

1 January 2016 in Optometry and Vision Science
Verified
Journal Article
Closed access
HWHendrik Walther
Hendrik Walther
LSLakshman Subbaraman
Lakshman Subbaraman
Lyndon JonesLyndon Jones
Lyndon Jones

25 February 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Chau-Minh PhanChau-Minh Phan
Chau-Minh Phan
Manish ShuklaManish Shukla
Manish Shukla
HWHendrik Walther
Hendrik Walther
MHMiriam Heynen
Miriam Heynen
DSDavid Suh
David Suh
Lyndon JonesLyndon Jones
Lyndon Jones
Purpose: The purpose of this study was to develop an advanced in vitro blink model that can be used to examine the release of a wide variety of components (for example, topical ophthalmic drugs, comfort-inducing agents) from soft contact lenses. Methods: The model was designed using computer-aided design software and printed using a stereolithography 3D printer. The eyelid and eyeball were synthesized from polyvinyl alcohol and silicone material, respectively. Simulated tear fluid was infused through tubing attached to the eyelid using a syringe pump. With each blink cycle, the eyelid slides and flexes across the eyeball to create an artificial tear film layer. The flow-through fluid was collected using a specialized trough. Two contact lenses, etafilcon A and senofilcon A, were incubated in 2 mL of a water-soluble red dye for 24 h and then placed on the eye model (n = 3). The release of the dye was measured over 24 h using a tear flow rate of 5 µL/min. Results: Approximately 25% of the fluid that flowed over the eye model was lost due to evaporation, nonspecific absorption, and residual dead volume. Senofilcon A absorbed more dye (47.6 ± 2.7 µL) than etafilcon A (22.3 ± 2.0 µL). For etafilcon A, the release of the dye followed a burst-plateau profile in the vial but was sustained in the eye model. For senofilcon A, the release of the dye was sustained in both the vial and the eye model, though more dye was released in the vial (p < 0.05). Overall, the release of the dye from the contact lenses was higher in the vial compared with the eye model (p < 0.05). Conclusion: The blink model developed in this study could be used to measure the release of topical ophthalmic drugs or comfort agents from contact lenses. Simulation of a blink mechanism, an artificial tear film, and nonspecific absorption in an eye model may provide better results than a simple, static vial incubation model.

16 October 2018 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
PDF file
Chau-Minh PhanChau-Minh Phan
Chau-Minh Phan
HWHendrik Walther
Hendrik Walther
DRDonald Riederer
Donald Riederer
CLCharis Lau
Charis Lau
KLKathrine Osborn Lorenz
Kathrine Osborn Lorenz
Lyndon JonesLyndon Jones
Lyndon Jones
The purpose of this work was to determine the release of polyvinyl alcohol (PVA) from etafilcon A, omafilcon A, and nelfilcon A daily disposable hydrogel contact lenses using a novel in vitro model. PVA is an ocular lubricant that can be found in multiple formulations of artificial tears. Nelfilcon A innately contains PVA, so only the release of PVA from this lens was evaluated. Etafilcon A and omafilcon A lenses were incubated in a PBS solution containing PVA. The release of PVA was evaluated using a novel in vitro blink platform with Milli‐Q water and PBS under various blink conditions and flow rates. Nelfilcon A lenses significantly released more PVA than other lenses at 0.5 and 1.5 h in both PBS and Milli‐Q water (p < 0.001). For nelfilcon A, there was no statistical significance between the release profiles of PVA between the blink and no‐blink conditions, or for the various flow rates (p > 0.05). All tested groups and lenses showed a burst release within the first 4.5 h and rapidly plateaued thereafter. The current study demonstrates that releasable PVA (whether through uptake or through being inherently available from the material) is loosely bound on hydrogel lenses, and the majority is released within 4.5 h. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1662–1668, 2019.

1 March 2018 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
HWHendrik Walther
Hendrik Walther
CPChau-Minh Phan
Chau-Minh Phan
LSLakshman N. Subbaraman
Lakshman N. Subbaraman
Lyndon JonesLyndon Jones
Lyndon Jones
Purpose: We evaluate the differences in lipid uptake and penetration in daily disposable (DD) contact lenses (CL) using a conventional “in-vial” method compared to a novel in vitro eye model. Methods: The penetration of fluorescently labelled 22-(N-(7-Nitrobenz-2-Oxa-1,3-Diazol-4-yl)Amino)-23,24-Bisnor-5-Cholen-3beta-Ol (NBD)–cholesterol on three silicone hydrogel (SH) and four conventional hydrogel (CH) DD CLs were investigated. CLs were incubated for 4 and 12 hours in a vial, containing 3.5 mL artificial tear solution (ATS), or were mounted on an in vitro eye-blink platform designed to simulate physiologic tear flow (2 mL/24 hours), tear volume and “simulated” blinking. Subsequently, CLs were analyzed using laser scanning confocal microscopy and ImageJ. Results: Penetration depth and fluorescence intensities of NBD-cholesterol varied between the incubation methods as well as lens materials. Using the traditional vial incubation method, NBD-cholesterol uptake occurred equally on both sides of all lens materials. However, using our eye-blink model, cholesterol penetration was observed primarily on the anterior surface of the CLs. In general, SH lenses showed higher intensities of NBD-cholesterol than CH materials. Conclusions: The traditional “in-vial” incubation method exposes the CLs to an excessively high amount of ATS, which results in an overestimation for cholesterol deposition. Our model, which incorporates important ocular factors, such as intermittent air exposure, small tear volume, and physiological tear flow between blinks, provides a more natural environment for in vitro lens incubation. Translational Relevance: In vitro measurements of CLs are a common approach to predict their interactions and performance on the eye. Traditional methods, however, are rudimentary. Therefore, this study presents a novel in vitro model to evaluate CLs, which consequently will enhance elucidations of the interactions between CLs and the eye.

2 November 2018 in Journal of Biomaterials Science, Polymer Edition
Verified
Journal Article
Open access
Chau-Minh PhanChau-Minh Phan
Chau-Minh Phan
HWHendrik Walther
Hendrik Walther
RSRichard W. Smith
Richard W. Smith
DRDonald Riederer
Donald Riederer
CLCharis Lau
Charis Lau
Lyndon JonesLyndon Jones
Lyndon Jones
The traditional method to measure release of components from CLs is a vial containing a static volume of PBS (phosphate buffered saline). However, this model does not simulate physiologically relevant tear volume and natural tear flow, air exposure, and mechanical rubbing. These factors can significantly impact release kinetics. We have developed an in vitro eye model (OcuFlow) that simulates these parameters. The aim of the study was to measure the release of PEG (polyethylene glycol), and HPMC (hydroxypropyl methylcellulose) from a daily disposable hydrogel contact lens material (nelfilcon A; Dailies AquaComfort PLUS; DACP;) over 24 hrs using the OcuFlow platform. The elution of PEG and HPMC from DACP lenses was analyzed using LCMS (liquid chromatography mass spectrometry). The release of all wetting agents from the lenses followed a burst release pattern, which occurred within the first 1.5 hrs (P < 0.05). The release of PEG was greater than that of HPMC (P < 0.05). The amount of PEG and HPMC released at any given time was less than 1% of the amount in the blister pack solution. Our results suggest that HPMC and PEG are rapidly released from the CL.