A study of the stochastic description of the Talbot effect in the temporal domain under random timing jitter is presented. The relevant statistical quantity is the variance. The variance of a train of pulses, each one affected by random timing jitter, shows peaks in the edges of the pulses. When this train is Talbot-imaged, the variance becomes flattened along the unit interval corresponding to each pulse as a result of the dispersion of the individual pulses of the train. Fractional Talbot devices are also analyzed. In particular, it is shown that this smoothing effect also occurs in Talbot devices leading to repetition rates of the original train.
The SARS-CoV-2 pandemic has led to a global decrease in personal protective equipment (PPE), especially filtering facepiece respirators (FFRs). Ultraviolet-C wavelength is a promising way of decontamination, however adequate dosimetry is needed to ensure balance between over and underexposed areas and provide reliable results. Our study demonstrates that UVGI light irradiance varies significantly on different respirator angles and propose a method to decontaminate several masks at once ensuring appropriate dosage in shaded zones. An UVGI irradiator was built with internal dimensions of 69.5 × 55 × 33 cm with three 15 W UV lamps. Inside, a grating of 58 × 41 × 15 cm was placed to hold the masks. Two different flat fold respirator models were used to assess irradiance, four of model Aura 9322 3 M of dimensions 17 × 9 × 4 cm (tri-fold), and two of model SAFE 231FFP3NR (bi-fold) with dimensions 17 × 6 × 5 cm. An STN-SilverNova spectrometer was employed to verify wavelength spectrum and surface irradiance. A simulation was performed to find the irradiance pattern inside the box and the six masks placed inside. These simulations were carried out using the software DIALUX EVO 8.2. The data obtained reveal that the irradiance received inside the manufactured UVGI-irradiator depends not only on the distance between the lamps' plane and the base of the respirators but also on the orientation and shape of the masks. This point becomes relevant to assure that all the respirators inside the chamber receive the correct dosage. Irradiance over FFR surfaces depend on several factors such as distance and angle of incidence of the light source. Careful irradiance measurement and simulation can ensure reliable dosage in the whole mask surface, balancing overexposure. Closed box systems might provide a more reliable, reproducible UVGI dosage than open settings.