Piotr Kędzia

Dr. Piotr Kędzia


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2013 in Applied Magnetic Resonance
Verified
Journal Article
Open access
PDF file
PKPiotr Kędzia
Piotr Kędzia
TCT. Czechowski
T. Czechowski
MBMikołaj Baranowski
Mikołaj Baranowski
JJJ. Jurga
J. Jurga
ESE. Szcześniak
E. Szcześniak
In this paper we use a simple analysis based on properties of the axial field generated by symmetrical multipoles to reveal all possible distributions of two coaxial pairs of circular windings, which result in systems featuring zero octupole and 32 pole magnetic moments (six-order systems). Homogeneity of magnetic field of selected systems is analyzed. It has been found that one of the derived systems generates homogenous magnetic field whose volume is comparable to that yielded by the eight-order system. The influence of the current distribution and the windings placement on the field homogeneity is considered. The table, graphs and equations given in the paper facilitate the choice of the most appropriate design for a given problem. The systems presented may find applications in low field electron paramagnetic resonance imaging, some functional f-MRI (nuclear magnetic resonance imaging) and bioelectromagnetic experiments requiring the access to the working space from all directions.

13 July 2012 in Applied Magnetic Resonance
Verified
Journal Article
Open access
PDF file
TCT. Czechowski
T. Czechowski
MBMikołaj Baranowski
Mikołaj Baranowski
AWAneta Wozniak-Braszak
Aneta Wozniak-Braszak
KJK. Jurga
K. Jurga
JJJ. Jurga
J. Jurga
PKPiotr Kędzia
Piotr Kędzia
The design and construction of a high-performance, low-cost, and easy to assemble adiabatic extension set for homebuilt and commercial spectrometers is described. Described apparatus set was designed for the fast adiabatic passage generation and is based on direct digital synthesizer DDS. This solution gives generator high signal to noise ratio, phase stability even during frequency change which is only possible in expansive commercial high-end hardware. Critical synchronization and timing issues are considered and solutions are discussed. Different experimental conditions and techniques for the measurements are briefly discussed. The proposed system is very flexible and might be used for the measurement of low-frequency nuclear magnetic resonance.

1 June 2014 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
TCT. Czechowski
T. Czechowski
WCW. Chlewicki
W. Chlewicki
MBMikołaj Baranowski
Mikołaj Baranowski
KJK. Jurga
K. Jurga
PSP. Szczepanik
P. Szczepanik
JJJ. Jurga
J. Jurga

1 October 2018 in Composite Structures
Verified
Journal Article
Closed access
EMEwa Magnucka-Blandzi
Ewa Magnucka-Blandzi
PKPiotr Kędzia
Piotr Kędzia
MSMikołaj Jan Smyczyński
Mikołaj Jan Smyczyński

1 November 2014 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
TCT. Czechowski
T. Czechowski
WCW. Chlewicki
W. Chlewicki
MBMikołaj Baranowski
Mikołaj Baranowski
KJK. Jurga
K. Jurga
PSP. Szczepanik
P. Szczepanik
JJJ. Jurga
J. Jurga

18 May 2018 in Applied Mathematics and Mechanics
Verified
Journal Article
Closed access
PDF file
EMEwa Magnucka-Blandzi
Ewa Magnucka-Blandzi
KWK. Wisniewska-Mleczko
K. Wisniewska-Mleczko
MSM. J. Smyczynski
M. J. Smyczynski
PKPiotr Kędzia
Piotr Kędzia