David C. Rotzinger

Dr. David C. Rotzinger

Lausanne University Hospital (CHUV), Lausanne, Switzerland
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Thrombosis Research
Verified
Journal Article
Closed access
David C. RotzingerDavid C. Rotzinger
David C. Rotzinger
CBC. Beigelman-Aubry
C. Beigelman-Aubry
CGC. von Garnier
C. von Garnier
SQS.D. Qanadli
S.D. Qanadli

1 August 2020 in Physica Medica
Verified
Journal Article
Open access
DRDamien Racine
Damien Racine
Fabio BecceFabio Becce
Fabio Becce
AVAnais Viry
Anais Viry
PMPascal Monnin
Pascal Monnin
BTBrian Thomsen
Brian Thomsen
David C. RotzingerDavid C. Rotzinger
David C. Rotzinger
We aimed to thoroughly characterize image quality of a novel deep learning image reconstruction (DLIR), and investigate its potential for dose reduction in abdominal CT in comparison with filtered back-projection (FBP) and a partial model-based iterative reconstruction (ASiR-V). We scanned a phantom at three dose levels: regular (7 mGy), low (3 mGy) and ultra-low (1 mGy). Images were reconstructed using DLIR (low, medium and high levels) and ASiR-V (0% = FBP, 50% and 100%). Noise and contrast-dependent spatial resolution were characterized by computing noise power spectra and target transfer functions, respectively. Detectability indexes of simulated acute appendicitis or colonic diverticulitis (low contrast), and calcium-containing urinary stones (high contrast) (|ΔHU| = 50 and 500, respectively) were calculated using the nonprewhitening with eye filter model observer. At all dose levels, increasing DLIR and ASiR-V levels both markedly decreased noise magnitude compared with FBP, with DLIR low and medium maintaining noise texture overall. For both low- and high-contrast spatial resolution, DLIR not only maintained, but even slightly enhanced spatial resolution in comparison with FBP across all dose levels. Conversely, increasing ASiR-V impaired low-contrast spatial resolution compared with FBP. Overall, DLIR outperformed ASiR-V in all simulated clinical scenarios. For both low- and high-contrast diagnostic tasks, increasing DLIR substantially enhanced detectability at any dose and contrast levels for any simulated lesion size. Unlike ASiR-V, DLIR substantially reduces noise while maintaining noise texture and slightly enhancing spatial resolution overall. DLIR outperforms ASiR-V by enabling higher detectability of both low- and high-contrast simulated abdominal lesions across all investigated dose levels.

3 June 2014 in Annals of Clinical and Translational Neurology
Verified
Journal Article
Open access
PDF file
GBGuillaume Bonnier
Guillaume Bonnier
ARAlexis Roche
Alexis Roche
DRDavid Romascano
David Romascano
SSSamanta Simioni
Samanta Simioni
DMDjalel Meskaldji
Djalel Meskaldji
CGCristina Granziera
Cristina Granziera
Introduction In patients with multiple sclerosis (MS), conventional magnetic resonance imaging (MRI) provides only limited insights into the nature of brain damage with modest clinic-radiological correlation. In this study, we applied recent advances in MRI techniques to study brain microstructural alterations in early relapsing-remitting MS (RRMS) patients with minor deficits. Further, we investigated the potential use of advanced MRI to predict functional performances in these patients. Methods Brain relaxometry (T1, T2, T2*) and magnetization transfer MRI were performed at 3T in 36 RRMS patients and 18 healthy controls (HC). Multicontrast analysis was used to assess for microstructural alterations in normal-appearing (NA) tissue and lesions. A generalized linear model was computed to predict clinical performance in patients using multicontrast MRI data, conventional MRI measures as well as demographic and behavioral data as covariates. Results Quantitative T2 and T2* relaxometry were significantly increased in temporal normal-appearing white matter (NAWM) of patients compared to HC, indicating subtle microedema (P = 0.03 and 0.004). Furthermore, significant T1 and magnetization transfer ratio (MTR) variations in lesions (mean T1 z-score: 4.42 and mean MTR z-score: −4.09) suggested substantial tissue loss. Combinations of multicontrast and conventional MRI data significantly predicted cognitive fatigue (P = 0.01, Adj-R2 = 0.4), attention (P = 0.0005, Adj-R2 = 0.6), and disability (P = 0.03, Adj-R2 = 0.4). Conclusion Advanced MRI techniques at 3T, unraveled the nature of brain tissue damage in early MS and substantially improved clinical–radiological correlations in patients with minor deficits, as compared to conventional measures of disease.

25 November 2015 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
MFMário João Fartaria
Mário João Fartaria
GBGuillaume Bonnier
Guillaume Bonnier
ARAlexis Roche
Alexis Roche
TKTobias Kober
Tobias Kober
RMReto Meuli
Reto Meuli
CGCristina Granziera
Cristina Granziera

1 July 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed
NDNicolas Dupuis
Nicolas Dupuis
VTValérie Tatard-Leitman
Valérie Tatard-Leitman
David C. RotzingerDavid C. Rotzinger
David C. Rotzinger
SBSara Boccalini
Sara Boccalini
LBLoic Boussel
Loic Boussel

19 March 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
David C. RotzingerDavid C. Rotzinger
David C. Rotzinger
SSSalim A. Si-Mohamed
Salim A. Si-Mohamed
JYJérôme Yerly
Jérôme Yerly
SBSara Boccalini
Sara Boccalini
FBFabio Becce
Fabio Becce
PDPhilippe C. Douek
Philippe C. Douek
Objectives: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. Materials and methods: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. Results: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). Conclusion: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. Key Points: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.