Stefanus Kristiawan

Prof. Dr. Stefanus Kristiawan

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
SKStefanus Kristiawan
Stefanus Kristiawan
MAM. Taib M. Aditya
M. Taib M. Aditya
Self-compacting concrete (SCC) has been produced incorporating fly ash as cement replacement at 35%, 55% and 65% by weight. The flowability, fillingability and passingability of these concrete were assessed by combination of the following test methods: flow table, J-Ring, L-Box, Box Type and V-funnel test. For each mix proportion of SCC, six cylinder specimens (75mm x 275mm) were cast for shrinkage measurements following the RILEM Recomendation. Three of them were used for measurement of drying shrinkage while the other three were used for autogenous shrinkage. The results show that a higher cement replacement by fly ash tends to decrease both drying and autogenous shrinkage. Estimations of shrinkage using ACI 209R, CEB-FIP 1990 and Ross's method suggest that ACI 209R and CEB-FIP 1990 provide accurate prediction than Ross's model


29 December 2021 in Buildings
Verified
Journal Article
Open access
PDF file
SKStefanus Kristiawan
Stefanus Kristiawan
IHIsyana Ratna Hapsari
Isyana Ratna Hapsari
EPEdy Purwanto
Edy Purwanto
MMMarwahyudi Marwahyudi
Marwahyudi Marwahyudi
Many damage limit states have been defined to characterize the extent of damages occurred in RC frame. Some of the damage limit states are defined by models that relate the limit states with the control points. Both control points and the limit state are expressed in term of response quantities. This research aims to evaluate the validity of such models by identifying the defined damage limit state with the corresponding damage based on FE modeling. The FE modeling provides a direct link between the damage and the response quantities. This link can be exploited as a basis for the evaluation. Based on the evaluation, this study proposed modified damage limit states. The response quantities with its corresponding progressive damage from FE simulation will also be used to inspect whether damage that can be expected to occur in the model structure is within the range estimated by the code based approach (CBA) damage limit state. Finally, fragility curves are constructed to assess the probability of the expected damage in the model structure under Design Basis Earthquake (DBE) and Maximum Considered Earthquake (MCE) scenarios. Utilizing the proposed damage limit states, the most probable damage in the structure falls in the category of slight if an earthquake at a level of DBE or MCE strikes the structure. However, at MCE level the probability of moderate damage attains 35%, or an increase by 23% compared to the DBE level.

1 January 2013 in Procedia Engineering
Verified
Journal Article
Open access
HSHendramawat A. Safarizki
Hendramawat A. Safarizki
SKStefanus Kristiawan
Stefanus Kristiawan
ABA. Basuki
A. Basuki
The aim of this paper is to evaluate the possible improvement of seismic performance of existing reinforced concrete building (the 5th Building of UNS Engineering Faculty) by the use of steel bracing. Three methods of seismic evaluation are employed for the purpose of the study i.e. Nonlinear Static Pushover Displacement Coefficient Method as described in FEMA 356, Improvement of Nonlinear Static Pushover Displacement Coefficient Method as described in FEMA 440 and dynamic time history analysis following the Indonesian Code of Seismic Resistance Building (SNI 03-1726-2002) criteria. The results show that the target displacement determined from nonlinear pushover analysis of the existing building in X direction is 0.188 m and in Y direction is 0.132 m. The performance of this building could be categorized in between Life Safety (LS) - Collapse Prevention (CP) and plastic hinges occur in columns. It is also indicated that the story drifts in Y direction exceed the serviceability limit criterion when the recorded El Centro accelerogram was used for dynamic time history analysis. The performance of the existing building could be improved if steel bracings are utilized for seismic retrofitting. It is shown from the nonlinear pushover analysis that target displacements in both directions are reduced by 16%-55% if the proposed steel bracings are used. Furthermore, dynamic time history analysis points out that the story drifts of the retrofitted building are within the limit criteria. Meanwhile, the size of steel bracing elements do not significantly affect the seismic performance of retrofitted building

21 February 2017 in Procedia Engineering
Verified
Journal Article
Open access
PDF file
LALinda Astriana
Linda Astriana
SSSenot Sangadji
Senot Sangadji
EPEdy Purwanto
Edy Purwanto
SKStefanus Kristiawan
Stefanus Kristiawan
Explosive population and economic development in the city has forced engineer to design and build more vertical buildings. In order to be resilient in earthquake prone region, these tall buildings have to achieve a specific level of performance under earthquake loading. A comprehensive methodology for assessing the seismic performance is required which can be attained by developing structural fragility function of the structure. Fragility curves is a probabilistic function relating damage level (engineering demand parameter) with intensity measure, i.e. spectral acceleration. This paper investigates the seismic performance of moment resisting frame as compared to frame-wall system of structures. The structural response of fully deterministic structural models was, then, analyzed employing nonlinear pushover analysis yielding capacity spectrums. For each capacity spectrum in every building system, the damage states were defined, whereas average inter-story drift values for each damage state were converted into corresponding amount of spectral acceleration leading to the development of fragility curves. The paper is concluded by carrying out evaluation of the damage state based on HAZUS-MH MR5 and ATC-40.

20 April 2021 in Buildings
Verified
Journal Article
Open access
PDF file
ABAgus Setiya Budi
Agus Setiya Budi
ESEndah Safitri
Endah Safitri
SSSenot Sangadji
Senot Sangadji
SKStefanus Kristiawan
Stefanus Kristiawan
Various concretes have been developed to meet the principles of sustainability. High volume fly ash-self compacting concrete (HVFA-SCC) is one example. The utilization of HVFA-SCC for structural applications, however, raises a concern among designers: that HVFA-SCC may not be as strong as conventional concrete when carrying shear forces. This concern is related to slow strength development and relatively smoother crack surface formation in HVFA-SCC, which, consequently, reduces the aggregate interlock mechanism contribution to the shear strength. In this respect, the design code for estimating the shear strength of HVFA-SCC may not be valid for the reason that the code was developed on the basis of the conventional concrete database. Previous research on the shear strength of HVFA-SCC was limited and no database can be extracted to justify the validity of the shear design code. This research was conducted to clarify the suitability of shear design code for HVFA-SCC. The research began with a limited laboratory investigation, followed by a numerical investigation to expand the range of results. Two types of HVFA-SCC beams with dimensions of 100 mm × 150 mm × 1700 mm were prepared, utilizing 50% and 60% fly ash. The shear behavior obtained from the laboratory investigations was then numerically modeled with the help of 3D ATENA Engineering software. The numerical model was used to explore the influence of reinforcement ratio, shear span to beam effective depth ratio, and beam size on the shear strength of the HVFA-SCC beam. The results were compared with the shear strength database of conventional and unconventional concrete beams to judge if the provisions in the design code can be applied to the shear design of an HVFA-SCC beam. The results confirm that the ACI shear design code is applicable for HVFA-SCC.