Li-Wen Lee

Dr. Li-Wen Lee

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LLLi-Wen Lee
Li-Wen Lee
YLYu-San Liao
Yu-San Liao
HLHsueh-Kuan Lu
Hsueh-Kuan Lu
PHPei-Lin Hsiao
Pei-Lin Hsiao
YCYu-Yawn Chen
Yu-Yawn Chen
KHKuen-Chang Hsieh
Kuen-Chang Hsieh
Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have been performed on adult Caucasians. The present cross-sectional study investigated the validity of two portable BIA devices, the Inbody 230 (BIA8MF) and the Tanita BC-418 (BIA8SF), in healthy Taiwanese children. Children aged 7–12 years (72 boys and 78 girls) were recruited. Body composition was measured by the BIA8SF and the BIA8MF. Dual X-ray absorptiometry (DXA) was used as the reference method. There were strong linear correlations in body composition measurements between the BIA8SF and DXA and between the BIA8MF and DXA. Both BIAs underestimated fat mass (FM) and percentage body fat (%BF) relative to DXA in both genders The degree of agreement in lean body mass (LBM), FM, and %BF estimates was higher between BIA8MF and DXA than between BIA8SF and DXA. The Lin’s concordance correlation coefficient (ρc) for LBM8MF met the criteria of substantial to perfect agreement whereas the ρc for FM8MF met the criteria of fair to substantial agreement. Bland-Altman analysis showed a clinically acceptable agreement between LBM measures by BIA8MF and DXA. The limit of agreement in %BF estimation by BIA and DXA were wide and the errors were clinically important. For the estimation of ALM, BIA8SF and BIA8MF both provided poor accuracy. For all children, LBM measures were precise and accurate using the BIA8MF whereas clinically significant errors occurred in FM and %BF estimates. Both BIAs underestimated FM and %BF in children. Thus, the body composition results obtained using the inbuilt equations of the BIA8SF and BIA8MF should be interpreted with caution, and high quality validation studies for specific subgroups of children are required prior to field research.

Verified
Journal Article
Open access
PDF file
Jrhau LungJrhau Lung
Jrhau Lung
MHMing-Szu Hung
Ming-Szu Hung
TWTing-Yao Wang
Ting-Yao Wang
KCKuan-Liang Chen
Kuan-Liang Chen
CLChi-Wen Luo
Chi-Wen Luo
YLYu-Ching Lin
Yu-Ching Lin
For rapid and unlimited cell growth and proliferation, cancer cells require large quantities of nutrients. Many metabolic pathways and nutrient uptake systems are frequently reprogrammed and upregulated to meet the demand from cancer cells, including the demand for lipids. The lipids for most adult normal cells are mainly acquired from the circulatory system. Whether different cancer cells adopt identical mechanisms to ensure sufficient lipid supply, and whether the lipid demand and supply meet each other, remains unclear, and was investigated in lung cancer cells. Results showed that, despite frequent upregulation in de novo lipogenesis and the lipid transporter system, different lung cancer cells adopt different proteins to acquire sufficient lipids, and the lipid supply frequently exceeds the demand, as significant amounts of lipids stored in the lipid droplets could be found within lung cancer cells. Lipid droplet surface protein, PLIN3, was found frequently overexpressed since the early stage in lung cancer tissues. Although the expression is not significantly associated with a specific gender, age, histology type, disease stage, and smoking habit, the frequently elevated expression of PLIN3 protein indicates the importance of lipid droplets for lung cancer. These lipid droplets are not only for nutrient storage, but are also crucial for tumor growth and proliferation, as well as survival in starvation. These results suggest that manipulation of lipid droplet formation or TG storage in lung cancer cells could potentially decrease the progression of lung cancer. Further exploration of lipid biology in lung cancer could help design novel treatment strategies.

8 April 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
CLChia-Ni Lin
Chia-Ni Lin
WHWeh-Shih Huang
Weh-Shih Huang
THTzu Hao Huang
Tzu Hao Huang
CCChao-Yu Chen
Chao-Yu Chen
CHCheng Yi Huang
Cheng Yi Huang
LLLi-Wen Lee
Li-Wen Lee
Background: This study aimed to investigate the adding value of MRI over CT for preoperative cytoreductive surgery with hyperthermic intraperitoneal chemotherapies (CRS/HIPEC). Methods: Imaging and intraoperative peritoneal cancer index (PCI) were calculated in 62 patients with peritoneal metastasis. Predictive models for the completeness of cytoreductive score using PCI data were established using decision tree algorithms. Results: In gastric cancer patients, a large discrepancy and poor agreement was appreciated between CT and surgical PCI, and a nonsignificant difference was noted between MRI and surgical PCI. In colon cancer patients, a better agreement and higher correlation with a smaller error was observed in PCI score using MRI than in that using CT. However, the addition of MRI to CT was limited for appendiceal and ovarian cancer patients. For predicting incomplete cytoreduction, CT models yielded inadequate accuracy while MRI models were more accurate with fair discrimination ability. Conclusions: CT was suitable for estimating PCI and surgery outcome in appendiceal and ovarian cancer patients, while further MRI in addition to CT was recommended for colon and gastric cancer patients. However, for classifying patients with peritoneal carcinomatosis into complete and incomplete cytoreduction, MRI was more effective than CT.

10 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LLLi-Wen Lee
Li-Wen Lee
CLChieh-Mo Lin
Chieh-Mo Lin
HLHung-Chou Li
Hung-Chou Li
PHPei-Lin Hsiao
Pei-Lin Hsiao
ACAn-Chi Chung
An-Chi Chung
SHShu-Feng Hsu
Shu-Feng Hsu
Chronic obstructive pulmonary disease (COPD) mainly affects middle-age and elderly adults. It is unclear if the presence of muscle wasting and fat accumulation in patients with COPD is age or disease-related. This study investigated the effect of age and COPD disease severity on body composition with the aim of identifying a biomarker(s) for COPD. Healthy subjects and patients with COPD of different severity were recruited. Dual-energy X-ray absorptiometry was used to analyze total and segmental body composition. Subjects included in the analysis were classified into four groups: healthy young (aged 20–45 years) (n = 35), healthy old (aged ≥ 60 years) (n = 37), moderate COPD (n = 40), and severe COPD (n = 14). In healthy old adults, leg and limb lean masses were lower by 10.6% and 8.5%, respectively, compared with healthy young adults (P < 0.05). Appendicular lean outcomes were significantly lower in the moderate COPD compared to the healthy old group and were significant lower in subjects with severe COPD compared to those with moderate COPD. All fat depots were similar for both young and old healthy subjects and subjects with moderate COPD, but significantly decreased in patients with severe COPD. This study examined the changes in total and segmental body composition with aging and COPD severity. It found that aging and COPD altered the body composition differently, and the effect was most pronounced in leg lean mass. Remarkably, differences in appendicular lean masses were seen in mild COPD although no changes in body weight or BMI were apparent compared with healthy young adults. In contrast, fat depot changes were only observed in severe COPD. Aging and COPD processes are multifactorial and additional longitudinal studies are required to explore both the quantitative and qualitative changes in body composition with aging and disease process.

9 July 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SWShiou-An Wang
Shiou-An Wang
MLMing-Hua Lu
Ming-Hua Lu
ALAi-Teng Lee
Ai-Teng Lee
CCChao-Yu Chen
Chao-Yu Chen
LLLi-Wen Lee
Li-Wen Lee
The Microsoft Kinect depth sensor, with its built-in software that automatically captures joint coordinates without markers, could be a potential tool for ergonomic studies. This study investigates the performance of Kinect in limb segment lengths using dual-energy X-ray absorptiometry (DXA) as a reference. Healthy children and adults (n = 76) were recruited for limb length measurements by Kinect and DXA. The results showed consistent ratios of arm, forearm, thigh, and leg lengths to height, which were 0.16, 0.14, 0.23, and 0.22 respectively, for both age groups and methods. Kinect exhibited perfect correlation among all limb lengths, indicating fixed proportions assumed by its algorithm. Comparing the two methods, there was a strong correlation (R = 0.850–0.985) and good to excellent agreement (ICC = 0.829–0.977), except for the right leg in adults, where agreement was slightly lower but still moderate (ICC = 0.712). The measurement bias between the methods ranged from − 1.455 to 0.536 cm. In conclusion, Kinect yields outcomes similar to DXA, indicating its potential utility as a tool for ergonomic studies. However, the built-in algorithm of Kinect assumes fixed limb proportions for individuals, which may not be ideal for studies focusing on investigating limb discrepancies or anatomical differences.

21 June 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CLChia-Ni Lin
Chia-Ni Lin
YLYu-San Liao
Yu-San Liao
WCWen-Chang Chen
Wen-Chang Chen
YWYue-Sheng Wang
Yue-Sheng Wang
LLLi-Wen Lee
Li-Wen Lee
Myometrial smooth muscle is normally within the field of view for the gynecological imaging. This study aimed to investigate the use of normal myometrium as an internal reference for endometrial and cervical cancer during multiphase contrast-enhanced magnetic resonance imaging (MCE-MRI) and to explore whether this information regarding tumor enhancement relative to the myometrium could be used to discriminate between endometrial and cervical cancer. MRI images, before and after contrast enhancement, were analyzed in newly diagnosed cervical (n = 18) and endometrial cancer (n = 19) patients. Signal intensities (SIs) from tumor tissue and non-neoplastic myometrium were measured using imaging software. The relative signal for cervical cancer was approximately 30% higher than that of endometrial cancer after contrast administration. The area under receiver operating characteristic curve for SI, relative signal enhancement, and tumor to myometrium contrast ratio (as used to discriminate between cervical cancer and endometrial cancer) was 0.7807, 0.7456 and 0.7895, respectively. There was no difference in SI of the normal myometrium between endometrial and cervical cancer patients prior to and after contrast administration. Using non-tumorous myometrium as an internal reference, the tumor to myometrium contrast ratio was significantly higher in tumor tissue from cervical cancer compared with that from endometrial cancer at 25 s post contrast enhancement (p = 0.0016), with an optimal sensitivity of 72.22% and specificity of 84.21%. With SI normalized to baseline or normal myometrium, tumor tissue from cervical cancer patients showed significant hyperintensity compared with that of tumor tissue from endometrial cancer patients after contrast enhancement, yielding acceptable performance. The use of the myometrium as an internal reference may provide an alternative method to analyze MCE-MRI data.