Although guidelines recommend fixed cardiac troponin thresholds for the diagnosis of myocardial infarction, troponin concentrations are influenced by age, sex, comorbidities and time from symptom onset. To improve diagnosis, we developed machine learning models that integrate cardiac troponin concentrations at presentation or on serial testing with clinical features and compute the Collaboration for the Diagnosis and Evaluation of Acute Coronary Syndrome (CoDE-ACS) score (0–100) that corresponds to an individual’s probability of myocardial infarction. The models were trained on data from 10,038 patients (48% women), and their performance was externally validated using data from 10,286 patients (35% women) from seven cohorts. CoDE-ACS had excellent discrimination for myocardial infarction (area under curve, 0.953; 95% confidence interval, 0.947–0.958), performed well across subgroups and identified more patients at presentation as low probability of having myocardial infarction than fixed cardiac troponin thresholds (61 versus 27%) with a similar negative predictive value and fewer as high probability of having myocardial infarction (10 versus 16%) with a greater positive predictive value. Patients identified as having a low probability of myocardial infarction had a lower rate of cardiac death than those with intermediate or high probability 30 days (0.1 versus 0.5 and 1.8%) and 1 year (0.3 versus 2.8 and 4.2%; P < 0.001 for both) from patient presentation. CoDE-ACS used as a clinical decision support system has the potential to reduce hospital admissions and have major benefits for patients and health care providers.

1 July 2019 in JACC
Verified
Journal Article
Closed access
RTRaphael Twerenbold
Raphael Twerenbold
JCJuan Pablo Costabel
Juan Pablo Costabel
TNThomas Nestelberger
Thomas Nestelberger
RCRoberto Campos
Roberto Campos
DWDesiree Wussler
Desiree Wussler
CMChristian Müller
Christian Müller

14 June 2022 in Circulation
Verified
Journal Article
Open access
PDF file
JLJeanne du Fay de Lavallaz
Jeanne du Fay de Lavallaz
APAlexandra Prepoudis
Alexandra Prepoudis
MWMaria Janina Wendebourg
Maria Janina Wendebourg
EKEva Kesenheimer
Eva Kesenheimer
DKDiego Kyburz
Diego Kyburz
CMChristian Müller
Christian Müller
Background: Cardiac troponin (cTn) T and cTnI are considered cardiac specific and equivalent in the diagnosis of acute myocardial infarction. Previous studies suggested rare skeletal myopathies as a noncardiac source of cTnT. We aimed to confirm the reliability/cardiac specificity of cTnT in patients with various skeletal muscle disorders (SMDs). Methods: We prospectively enrolled patients presenting with muscular complaints (≥2 weeks) for elective evaluation in 4 hospitals in 2 countries. After a cardiac workup, patients were adjudicated into 3 predefined cardiac disease categories. Concentrations of cTnT/I and resulting cTnT/I mismatches were assessed with high-sensitivity (hs-) cTnT (hs-cTnT–Elecsys) and 3 hs-cTnI assays (hs-cTnI–Architect, hs-cTnI–Access, hs-cTnI–Vista) and compared with those of control subjects without SMD presenting with adjudicated noncardiac chest pain to the emergency department (n=3508; mean age, 55 years; 37% female). In patients with available skeletal muscle biopsies, TNNT/I1-3 mRNA differential gene expression was compared with biopsies obtained in control subjects without SMD. Results: Among 211 patients (mean age, 57 years; 42% female), 108 (51%) were adjudicated to having no cardiac disease, 44 (21%) to having mild disease, and 59 (28%) to having severe cardiac disease. hs-cTnT/I concentrations significantly increased from patients with no to those with mild and severe cardiac disease for all assays (all P <0.001). hs-cTnT–Elecsys concentrations were significantly higher in patients with SMD versus control subjects (median, 16 ng/L [interquartile range (IQR), 7–32.5 ng/L] versus 5 ng/L [IQR, 3–9 ng/L]; P <0.001), whereas hs-cTnI concentrations were mostly similar (hs-cTnI–Architect, 2.5 ng/L [IQR, 1.2–6.2 ng/L] versus 2.9 ng/L [IQR, 1.8–5.0 ng/L]; hs-cTnI–Access, 3.3 ng/L [IQR, 2.4–6.1 ng/L] versus 2.7 ng/L [IQR, 1.6–5.0 ng/L]; and hs-cTnI–Vista, 7.4 ng/L [IQR, 5.2–13.4 ng/L] versus 7.5 ng/L [IQR, 6–10 ng/L]). hs-cTnT–Elecsys concentrations were above the upper limit of normal in 55% of patients with SMD versus 13% of control subjects ( P <0.01). mRNA analyses in skeletal muscle biopsies (n=33), mostly (n=24) from individuals with noninflammatory myopathy and myositis, showed 8-fold upregulation of TNNT2 , encoding cTnT (but none for TNNI3 , encoding cTnI) versus control subjects (n=16, P Wald <0.001); the expression correlated with pathological disease activity ( R =0.59, P t-statistic <0.001) and circulating hs-cTnT concentrations ( R =0.26, P t-statistic =0.031). Conclusions: In patients with active chronic SMD, elevations in cTnT concentrations are common and not attributable to cardiac disease in the majority. This was not observed for cTnI and may be explained in part by re-expression of cTnT in skeletal muscle. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03660969.

1 November 2019 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
JBJasper Boeddinghaus
Jasper Boeddinghaus
RTRaphael Twerenbold
Raphael Twerenbold
TNThomas Nestelberger
Thomas Nestelberger
LKLuca Koechlin
Luca Koechlin
DWDesiree Wussler
Desiree Wussler
PMPiotr Muzyk
Piotr Muzyk
BACKGROUND: We aimed to validate the clinical performance of the high-sensitivity cardiac troponin I [VITROS® Immunodiagnostic Products hs Troponin I (hs-cTnI-VITROS)] assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists considering all clinical information, including cardiac imaging: first, using serial hs-cTnT-Elecsys (primary analysis) and, second, using hs-cTnI-Architect (secondary analysis) measurements in addition to the clinically used (hs)-cTn. hs-cTnI-VITROS was measured at presentation and at 1 h in a blinded fashion. The primary objective was direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI-VITROS vs hs-cTnT-Elecsys and hs-cTnI-Architect, and in a subgroup also hs-cTnI-Centaur and hs-cTnI-Access. Secondary objectives included the derivation and validation of an hs-cTnI-VITROS-0/1-h algorithm. RESULTS: AMI was the adjudicated final diagnosis in 158 of 1231 (13%) patients. At presentation, the AUC for hs-cTnI-VITROS was 0.95 (95% CI, 0.93–0.96); for hs-cTnT-Elecsys, 0.94 (95% CI, 0.92–0.95); and for hs-cTnI-Architect, 0.92 (95% CI, 0.90–0.94). AUCs for hs-cTnI-Centaur and hs-cTnI-Access were 0.95 (95% CI, 0.94–0.97). Applying the derived hs-cTnI-VITROS-0/1-h algorithm (derivation cohort n = 519) to the validation cohort (n = 520), 53% of patients were ruled out [sensitivity, 100% (95% CI, 94.1–100)] and 14% of patients were ruled in [specificity, 95.6% (95% CI, 93.4–97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 99.8% at 30 days. Findings were confirmed in the secondary analyses using the adjudication including serial measurements of hs-cTnI-Architect. CONCLUSIONS: The hs-cTnI-VITROS assay has at least comparable diagnostic accuracy with the currently best validated hs-cTnT and hs-cTnI assays. ClinicalTrials.gov Identifier: NCT00470587.

2 April 2024 in Circulation
Verified
Journal Article
Closed access
Jasper BoeddinghausJasper Boeddinghaus
Jasper Boeddinghaus
DDDimitrios Doudesis
Dimitrios Doudesis
PAPedro Lopez Ayala
Pedro Lopez Ayala
KLKuan Ken Lee
Kuan Ken Lee
LKLuca Koechlin
Luca Koechlin
AEArnold von Eckardstein
Arnold von Eckardstein
BACKGROUND: Collaboration for the Diagnosis and Evaluation of Acute Coronary Syndrome (CoDE-ACS) is a validated clinical decision support tool that uses machine learning with or without serial cardiac troponin measurements at a flexible time point to calculate the probability of myocardial infarction (MI). How CoDE-ACS performs at different time points for serial measurement and compares with guideline-recommended diagnostic pathways that rely on fixed thresholds and time points is uncertain. METHODS: Patients with possible MI without ST-segment–elevation were enrolled at 12 sites in 5 countries and underwent serial high-sensitivity cardiac troponin I concentration measurement at 0, 1, and 2 hours. Diagnostic performance of the CoDE-ACS model at each time point was determined for index type 1 MI and the effectiveness of previously validated low- and high-probability scores compared with guideline-recommended European Society of Cardiology (ESC) 0/1-hour, ESC 0/2-hour, and High-STEACS (High-Sensitivity Troponin in the Evaluation of Patients With Suspected Acute Coronary Syndrome) pathways. RESULTS: In total, 4105 patients (mean age, 61 years [interquartile range, 50–74]; 32% women) were included, among whom 575 (14%) had type 1 MI. At presentation, CoDE-ACS identified 56% of patients as low probability, with a negative predictive value and sensitivity of 99.7% (95% CI, 99.5%–99.9%) and 99.0% (98.6%–99.2%), ruling out more patients than the ESC 0-hour and High-STEACS (25% and 35%) pathways. Incorporating a second cardiac troponin measurement, CoDE-ACS identified 65% or 68% of patients as low probability at 1 or 2 hours, for an identical negative predictive value of 99.7% (99.5%–99.9%); 19% or 18% as high probability, with a positive predictive value of 64.9% (63.5%–66.4%) and 68.8% (67.3%–70.1%); and 16% or 14% as intermediate probability. In comparison, after serial measurements, the ESC 0/1-hour, ESC 0/2-hour, and High-STEACS pathways identified 49%, 53%, and 71% of patients as low risk, with a negative predictive value of 100% (99.9%–100%), 100% (99.9%–100%), and 99.7% (99.5%–99.8%); and 20%, 19%, or 29% as high risk, with a positive predictive value of 61.5% (60.0%–63.0%), 65.8% (64.3%–67.2%), and 48.3% (46.8%–49.8%), resulting in 31%, 28%, or 0%, who require further observation in the emergency department, respectively. CONCLUSIONS: CoDE-ACS performs consistently irrespective of the timing of serial cardiac troponin measurement, identifying more patients as low probability with comparable performance to guideline-recommended pathways for MI. Whether care guided by probabilities can improve the early diagnosis of MI requires prospective evaluation. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT00470587.

1 November 2019 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
TNThomas Nestelberger
Thomas Nestelberger
JBJasper Boeddinghaus
Jasper Boeddinghaus
JGJaimi Greenslade
Jaimi Greenslade
WPWilliam A Parsonage
William A Parsonage
MTMartin Than
Martin Than
PMPiotr Muzyk
Piotr Muzyk
BACKGROUND: We aimed to derive and externally validate a 0/2-h algorithm using the high-sensitivity cardiac troponin I (hs-cTnI)-Access assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI) in 2 prospective diagnostic studies using central adjudication. Two independent cardiologists adjudicated the final diagnosis, including all available medical information including cardiac imaging. hs-cTnI-Access concentrations were measured at presentation and after 2 h in a blinded fashion. RESULTS: AMI was the adjudicated final diagnosis in 164 of 1131 (14.5%) patients in the derivation cohort. Rule-out by the hs-cTnI-Access 0/2-h algorithm was defined as 0-h hs-cTnI-Access concentration 3 h (direct rule-out) or a 0-h hs-cTnI-Access concentration <5 ng/L and an absolute change within 2 h <5 ng/L in all other patients. Derived thresholds for rule-in were a 0-h hs-cTnI-Access concentration ≥50 ng/L (direct rule-in) or an absolute change within 2 h ≥20 ng/L. In the derivation cohort, these cutoffs ruled out 55% of patients with a negative predictive value (NPV) of 99.8% (95% CI, 99.3–100) and sensitivity of 99.4% (95% CI, 96.5–99.9), and ruled in 30% of patients with a positive predictive value (PPV) of 73% (95% CI, 66.1–79). In the validation cohort, AMI was the adjudicated final diagnosis in 88 of 1280 (6.9%) patients. These cutoffs ruled out 77.9% of patients with an NPV of 99.8% (95% CI, 99.3–100) and sensitivity of 97.7% (95% CI, 92.0–99.7), and ruled in 5.8% of patients with a PPV of 77% (95% CI, 65.8–86) in the validation cohort. CONCLUSIONS: Safety and efficacy of the l hs-cTnI-Access 0/2-h algorithm for triage toward rule-out or rule-in of AMI are very high. TRIAL REGISTRATION: APACE, NCT00470587; ADAPT, ACTRN1261100106994; IMPACT, ACTRN12611000206921.