William Rhoads

Mr. William Rhoads


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2020 in AWWA Water Science
Verified
Journal Article
Open access
PDF file
CPCaitlin R. Proctor
Caitlin R. Proctor
WRWilliam Rhoads
William Rhoads
TKTim Keane
Tim Keane
MEMaryam Salehi Esfandarani
Maryam Salehi Esfandarani
Kerry HamiltonKerry Hamilton
Kerry Hamilton
AWAndrew J. Whelton
Andrew J. Whelton
The unprecedented number of building closures related to the coronavirus disease (COVID‐19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer‐reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.

1 December 2015 in Microbiome
Verified
Journal Article
Open access
PDF file
WRWilliam Rhoads
William Rhoads
PJPan Ji
Pan Ji
APAmy Pruden
Amy Pruden
MEMarc A. Edwards
Marc A. Edwards
Lowering water heater temperature set points and using less drinking water are common approaches to conserving water and energy; yet, there are discrepancies in past literature regarding the effects of water heater temperature and water use patterns on the occurrence of opportunistic pathogens, in particular Legionella pneumophila. Our objective was to conduct a controlled, replicated pilot-scale investigation to address this knowledge gap using continuously recirculating water heaters to examine five water heater set points (39–58 °C) under three water use conditions. We hypothesized that L. pneumophila levels at the tap depend on the collective influence of water heater temperature, flow frequency, and the resident plumbing ecology. We confirmed temperature setting to be a critical factor in suppressing L. pneumophila growth both in continuously recirculating hot water lines and at distal taps. For example, at 51 °C, planktonic L. pneumophila in recirculating lines was reduced by a factor of 28.7 compared to 39 °C and was prevented from re-colonizing biofilm. However, L. pneumophila still persisted up to 58 °C, with evidence that it was growing under the conditions of this study. Further, exposure to 51 °C water in a low-use tap appeared to optimally select for L. pneumophila (e.g., 125 times greater numbers than in high-use taps). We subsequently explored relationships among L. pneumophila and other ecologically relevant microbes, noting that elevated temperature did not have a general disinfecting effect in terms of total bacterial numbers. We documented the relationship between L. pneumophila and Legionella spp., and noted several instances of correlations with Vermamoeba vermiformis, and generally found that there is a dynamic relationship with this amoeba host over the range of temperatures and water use frequencies examined. Our study provides a new window of understanding into the microbial ecology of potable hot water systems and helps to resolve past discrepancies in the literature regarding the influence of water temperature and stagnation on L. pneumophila, which is the cause of a growing number of outbreaks. This work is especially timely, given society’s movement towards “green” buildings and the need to reconcile innovations in building design with public health.

5 November 2015 in Environmental Science: Water Research & Technology
Verified
Journal Article
Open access
PDF file
WRWilliam Rhoads
William Rhoads
APAmy Pruden
Amy Pruden
MEMarc A. Edwards
Marc A. Edwards
Widespread adoption of innovative water conservation strategies has potential unintended consequences for aesthetics and public health. A cross-section of green buildings were surveyed and compared to typical conventional buildings in terms of water retention time (i.e., water age), water chemistry, and levels of opportunistic pathogen genetic markers. Water age was estimated to be 2–6.7 months in an off-grid office, an average of 8 days in a Leadership in Environmental Engineering Design certified healthcare suite, and was increased to 2.7 days from 1 day due to installation of a solar “pre-heat” water tank in a net-zero energy house. Chlorine and chloramine residuals were often completely absent in the green building systems, decaying up to 144 times faster in premise plumbing with high water age when compared to distribution system water. Concentration of 16S rRNA and opportunistic pathogen genus level genetic markers were 1–4 orders of magnitude higher in green versus conventional buildings. This study raises concerns with respect to current green water system practices and the importance of considering potential public health impacts in the design of sustainable water systems.

26 September 2017 in Environmental Science & Technology
Verified
Journal Article
Closed access
WRWilliam Rhoads
William Rhoads
EGEmily Garner
Emily Garner
PJPan Ji
Pan Ji
NZNi Zhu
Ni Zhu
JPJeffrey Parks
Jeffrey Parks
MEMarc Edwards
Marc Edwards

1 June 2017 in Environmental Science & Technology
Verified
Journal Article
Closed access
WRWilliam Rhoads
William Rhoads
APAmy Pruden
Amy Pruden
MEMarc A. Edwards
Marc A. Edwards

25 May 2021 in Environmental Science & Technology
Verified
Journal Article
Open access
KPKelsey J. Pieper
Kelsey J. Pieper
CJC. Nathan Jones
C. Nathan Jones
WRWilliam Rhoads
William Rhoads
MRMcNamara Rome
McNamara Rome
DGDrew M. Gholson
Drew M. Gholson
RBR. Edward Beighley
R. Edward Beighley
Hurricane Hurricane Harvey made landfall on the Texas Gulf Coast on August 25, 2017, as a Category 4 hurricane and caused widespread flooding. We explored spatial and temporal distributions of well testing and contamination rates; relationships between contamination and system characteristics and recovery behaviors; and efficacy of mitigation strategies. We estimated that over 500 000 well users (∼130 000 to 260 000 wells) may have been affected, but only around 15 000 well users (∼3800 to 7500 wells) had inundated systems based on inundation maps. Local health departments and our team sampled 8822 wells in 44 counties in the 10 months that followed. Total coliform occurrence was 1.5 times and Escherichia coli was 2.8 times higher after Hurricane Harvey compared to baseline levels. Microbial contamination was more likely (1.7–2.5 times higher) when wells were inundated and/or residents felt their water was unsafe. Although more wells in urban counties were affected, E. coli rates were higher in wells in rural counties. Disinfection did not always eliminate contamination, highlighting concerns about the implementation and efficacy of chlorination procedures. Despite this extensive well testing conducted after Hurricane Harvey, we estimate that only 4.1% of potentially affected wells were tested, underscoring the magnitude of recovery assistance needed to assist well users after flooding events.