Won-Du Chang

Dr. Won-Du Chang

School of Electronic and Biomedical Engineering, Tongmyong University, Busan 48520, Korea
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2016 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
KLKwang-Ryeol Lee
Kwang-Ryeol Lee
WCWon-Du Chang
Won-Du Chang
SKSungkean Kim
Sungkean Kim
Chang-Hwan ImChang-Hwan Im
Chang-Hwan Im
Eye movements can be used as alternative inputs for human-computer interface (HCI) systems such as virtual or augmented reality systems as well as new communication ways for patients with locked-in syndrome. In this study, we developed a real-time electrooculogram (EOG)-based eye-writing recognition system, with which users can write predefined symbolic patterns with their volitional eye movements. For the “eye-writing” recognition, the proposed system first reconstructs the eye-written traces from EOG waveforms in real-time; then, the system recognizes the intended symbolic inputs with a reliable recognition rate by matching the input traces with the trained eye-written traces of diverse input patterns. Experiments with 20 participants showed an average recognition rate of 87.38% (F1 score) for 29 different symbolic patterns (26 lower case alphabet characters and three functional input patterns representing Space, Backspace, and Enter keys), demonstrating the promise of our EOG-based eye-writing recognition system in practical scenarios.

1 February 2016 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
WCWon-Du Chang
Won-Du Chang
HCHo-Seung Cha
Ho-Seung Cha
KKKiwoong Kim
Kiwoong Kim
Chang-Hwan ImChang-Hwan Im
Chang-Hwan Im

5 April 2016 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
HHHan-Jeong Hwang
Han-Jeong Hwang
HCHan Choi
Han Choi
JKJeong-Youn Kim
Jeong-Youn Kim
WCWon-Du Chang
Won-Du Chang
DKDo-Won Kim
Do-Won Kim
Chang-Hwan ImChang-Hwan Im
Chang-Hwan Im
In traditional brain–computer interface (BCI) studies, binary communication systems have generally been implemented using two mental tasks arbitrarily assigned to “yes” or “no” intentions (e.g., mental arithmetic calculation for “yes”). A recent pilot study performed with one paralyzed patient showed the possibility of a more intuitive paradigm for binary BCI communications, in which the patient’s internal yes/no intentions were directly decoded from functional near-infrared spectroscopy (fNIRS). We investigated whether such an “fNIRS-based direct intention decoding” paradigm can be reliably used for practical BCI communications. Eight healthy subjects participated in this study, and each participant was administered 70 disjunctive questions. Brain hemodynamic responses were recorded using a multichannel fNIRS device, while the participants were internally expressing “yes” or “no” intentions to each question. Different feature types, feature numbers, and time window sizes were tested to investigate optimal conditions for classifying the internal binary intentions. About 75% of the answers were correctly classified when the individual best feature set was employed (75.89% ±1.39 and 74.08% ±2.87 for oxygenated and deoxygenated hemoglobin responses, respectively), which was significantly higher than a random chance level (68.57% for p<0.001). The kurtosis feature showed the highest mean classification accuracy among all feature types. The grand-averaged hemodynamic responses showed that wide brain regions are associated with the processing of binary implicit intentions. Our experimental results demonstrated that direct decoding of internal binary intention has the potential to be used for implementing more intuitive and user-friendly communication systems for patients with motor disabilities.

14 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
WCWon-Du Chang
Won-Du Chang
Eye movements generate electric signals, which a user can employ to control his/her environment and communicate with others. This paper presents a review of previous studies on such electric signals, that is, electrooculograms (EOGs), from the perspective of human–computer interaction (HCI). EOGs represent one of the easiest means to estimate eye movements by using a low-cost device, and have been often considered and utilized for HCI applications, such as to facilitate typing on a virtual keyboard, moving a mouse, or controlling a wheelchair. The objective of this study is to summarize the experimental procedures of previous studies and provide a guide for researchers interested in this field. In this work the basic characteristics of EOGs, associated measurements, and signal processing and pattern recognition algorithms are briefly reviewed, and various applications reported in the existing literature are listed. It is expected that EOGs will be a useful source of communication in virtual reality environments, and can act as a valuable communication tools for people with amyotrophic lateral sclerosis.

8 September 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
WCWon-Du Chang
Won-Du Chang
HCHo-Seung Cha
Ho-Seung Cha
DKDo Yeon Kim
Do Yeon Kim
SKSeung hyun Kim
Seung hyun Kim
Chang-Hwan ImChang-Hwan Im
Chang-Hwan Im
Electrooculogram (EOG) can be used to continuously track eye movements and can thus be considered as an alternative to conventional camera-based eye trackers. Although many EOG-based eye tracking systems have been studied with the ultimate goal of providing a new way of communication for individuals with amyotrophic lateral sclerosis (ALS), most of them were tested with healthy people only. In this paper, we investigated the feasibility of EOG-based eye-writing as a new mode of communication for individuals with ALS. We developed an EOG-based eye-writing system and tested this system with 18 healthy participants and three participants with ALS. We also applied a new method for removing crosstalk between horizontal and vertical EOG components. All study participants were asked to eye-write specially designed patterns of 10 Arabic numbers three times after a short practice session. Our system achieved a mean recognition rates of 95.93% for healthy participants and showed recognition rates of 95.00%, 66.67%, and 93.33% for the three participants with ALS. The low recognition rates in one of the participants with ALS was mainly due to miswritten letters, the number of which decreased as the experiment proceeded. Our proposed eye-writing system is a feasible human-computer interface (HCI) tool for enabling practical communication of individuals with ALS.

18 February 2016 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
WCWon-Du Chang
Won-Du Chang
JLJeong-Hwan Lim
Jeong-Hwan Lim
Chang-Hwan ImChang-Hwan Im
Chang-Hwan Im
Electroencephalogram (EEG) is easily contaminated by unwanted physiological artifacts, among which electrooculogram (EOG) artifacts due to eye blinking are known to be most dominant. The eye blink artifacts are reported to affect theta and alpha rhythms of frontal EEG signals, and hard to be accurately detected in an unsupervised way due to large individual variability. In this study, we propose a new method for detecting eye blink artifacts automatically in real time without using any labeled training data. The proposed method combined our previous method for detecting eye blink artifacts based on digital filters with an automatic thresholding algorithm. The proposed method was evaluated using EEG data acquired from 24 participants. Two conventional algorithms were implemented and their performances were compared with that of the proposed method. The main contributions of this study are (1) confirming that individual thresholding is necessary for artifact detection, (2) proposing a novel algorithm structure to detect blink artifacts in a real-time environment without any a priori knowledge, and (3) demonstrating that the length of training data can be minimized through the use of a real-time adaption procedure.