Michael Zabala

Dr. Michael Zabala

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JCJordan Coker
Jordan Coker
HCHoward Chen
Howard Chen
MSMark Schall
Mark Schall
SGSean Gallagher
Sean Gallagher
MZMichael Zabala
Michael Zabala
Electromyography (EMG) is commonly used to measure electrical activity of the skeletal muscles. As exoskeleton technology advances, these signals may be used to predict human intent for control purposes. This study used an artificial neural network trained and tested with knee flexion angles and knee muscle EMG signals to predict knee flexion angles during gait at 50, 100, 150, and 200 ms into the future. The hypothesis of this study was that the algorithm’s prediction accuracy would only be affected by time into the future, not subject, gender or side, and that as time into the future increased, the prediction accuracy would decrease. A secondary hypothesis was that as the number of algorithm training trials increased, the prediction accuracy of the artificial neural network (ANN) would increase. The results of this study indicate that only time into the future affected the accuracy of knee flexion angle prediction (p < 0.001), whereby greater time resulted in reduced accuracy (0.68 to 4.62 degrees root mean square error (RMSE) from 50 to 200 ms). Additionally, increased number of training trials resulted in increased angle prediction accuracy.

18 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
INIvan Nail-Ulloa
Ivan Nail-Ulloa
MZMichael Zabala
Michael Zabala
RSRichard Sesek
Richard Sesek
HCHoward Chen
Howard Chen
MSMark Schall
Mark Schall
SGSean Gallagher
Sean Gallagher
This study assesses the agreement of compressive and shear force estimates at the L5-S1 joint using inertial motion capture (IMC) within a musculoskeletal simulation model during manual lifting tasks, compared against a top-down optical motion capture (OMC)-based model. Thirty-six participants completed lifting and lowering tasks while wearing a modified Plug-in Gait marker set for the OMC and a full-body IMC set-up consisting of 17 sensors. The study focused on tasks with variable load weights, lifting heights, and trunk rotation angles. It was found that the IMC system consistently underestimated the compressive forces by an average of 34% (975.16 N) and the shear forces by 30% (291.77 N) compared with the OMC system. A critical observation was the discrepancy in joint angle measurements, particularly in trunk flexion, where the IMC-based model underestimated the angles by 10.92–11.19 degrees on average, with the extremes reaching up to 28 degrees. This underestimation was more pronounced in tasks involving greater flexion, notably impacting the force estimates. Additionally, this study highlights significant differences in the distance from the spine to the box during these tasks. On average, the IMC system showed an 8 cm shorter distance on the X axis and a 12–13 cm shorter distance on the Z axis during lifting and lowering, respectively, indicating a consistent underestimation of the segment length compared with the OMC system. These discrepancies in the joint angles and distances suggest potential limitations of the IMC system’s sensor placement and model scaling. The load weight emerged as the most significant factor affecting force estimates, particularly at lower lifting heights, which involved more pronounced flexion movements. This study concludes that while the IMC system offers utility in ergonomic assessments, sensor placement and anthropometric modeling accuracy enhancements are imperative for more reliable force and kinematic estimations in occupational settings.

5 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DHDavid Hollinger
David Hollinger
MSMark Schall
Mark Schall
HCHoward Chen
Howard Chen
MZMichael Zabala
Michael Zabala
The use of wearable sensors, such as inertial measurement units (IMUs), and machine learning for human intent recognition in health-related areas has grown considerably. However, there is limited research exploring how IMU quantity and placement affect human movement intent prediction (HMIP) at the joint level. The objective of this study was to analyze various combinations of IMU input signals to maximize the machine learning prediction accuracy for multiple simple movements. We trained a Random Forest algorithm to predict future joint angles across these movements using various sensor features. We hypothesized that joint angle prediction accuracy would increase with the addition of IMUs attached to adjacent body segments and that non-adjacent IMUs would not increase the prediction accuracy. The results indicated that the addition of adjacent IMUs to current joint angle inputs did not significantly increase the prediction accuracy (RMSE of 1.92° vs. 3.32° at the ankle, 8.78° vs. 12.54° at the knee, and 5.48° vs. 9.67° at the hip). Additionally, including non-adjacent IMUs did not increase the prediction accuracy (RMSE of 5.35° vs. 5.55° at the ankle, 20.29° vs. 20.71° at the knee, and 14.86° vs. 13.55° at the hip). These results demonstrated how future joint angle prediction during simple movements did not improve with the addition of IMUs alongside current joint angle inputs.

12 November 2019 in Journal of Vibration and Acoustics
Verified
Journal Article
Closed access
PDF file
SKScott/M Kennedy
Scott/M Kennedy
MPMorgan Price
Morgan Price
MZMichael Zabala
Michael Zabala
EPEdmon Perkins
Edmon Perkins
This paper presents a shape memory alloy actuator design using a bimorph structure capable of high-speed actuation and low power consumption. Two active layers of shape memory alloy wires are separated by a passive layer of thermoplastic polyurethane. This structure results in a bending actuator when current is alternated between the two active shape memory alloy layers. Actuators of lengths 20, 25, 30, 35, and 40 mm were tested at peak current input of 110, 120, 130, and 140 mA. The 40-mm actuator was shown to have a natural frequency of 11.4 Hz with a bending displacement of 26.4 mm perpendicular to the neutral position and a power input of 0.78 W (140 mA peak current input). A relationship between the input current and the resulting vibratory characteristics was found. As the current increases, the natural frequency decreases and the damping ratio increases. The experimental results are compared with a finite element method (FEM) vibration analysis and an Euler–Bernoulli cantilever beam equations.

27 March 2019 in Applied Ergonomics
Verified
Journal Article
Closed access
MBMohamed Badawy
Mohamed Badawy
MSMark Schall
Mark Schall
MZMichael Zabala
Michael Zabala
JCJordan Coker
Jordan Coker
GDGerard A. Davis
Gerard A. Davis
SGSean Gallagher
Sean Gallagher

31 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RPRyan Pollard
Ryan Pollard
SBSarah M. Bass
Sarah M. Bass
MSMark Schall
Mark Schall
MZMichael Zabala
Michael Zabala
A common challenge for exoskeleton control is discerning operator intent to provide seamless actuation of the device with the operator. One way to accomplish this is with joint angle estimation algorithms and multiple sensors on the human–machine system. However, the question remains of what can be accomplished with just one sensor. The objective of this study was to deploy a modular testing approach to test the performance of two joint angle estimation models—a kinematic extrapolation algorithm and a Random Forest machine learning algorithm—when each was informed solely with kinematic gait data from a single potentiometer on an ankle exoskeleton mock-up. This study demonstrates (i) the feasibility of implementing a modular approach to exoskeleton mock-up evaluation to promote continuity between testing configurations and (ii) that a Random Forest algorithm yielded lower realized errors of estimated joint angles and a decreased actuation time than the kinematic model when deployed on the physical device.