Wang Seob Shim

Mr. Wang Seob Shim

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
SYSaebyul Yoo
Saebyul Yoo
BPBom-I Park
Bom-I Park
DKDo-Hyun Kim
Do-Hyun Kim
SLSooyoung Lee
Sooyoung Lee
SLSeung-Hoon Lee
Seung-Hoon Lee
BKBo-Hyung Kim
Bo-Hyung Kim
Red ginseng (RG) and black ginseng (BG, CJ EnerG) were prepared from fresh ginseng using one and nine cycles of steaming and drying, respectively. This process reduces the molecular weight (MW) of ginsenoside-active compounds in ginseng by removing sugar moieties from their dammaranes. We compared the pharmacokinetic characteristics of ginsenosides between BG comprising mainly low-MW ginsenosides (Rg3, Rg5, Rk1, and Rh1) and RG that predominantly contains high-MW ginsenosides (Rb1, Rb2, Rc, Rd, Re, and Rg1). The safety profiles and tolerability were also studied using a randomized, double-blind, single-dose, crossover clinical trial. A combination of Rb1, Rg1, and Rg3, well-known representative and functional RG components, exhibited a 1 h faster absorption rate (Tmax) and 58% higher exposure (24 h area under the concentration–time curve, AUC24) in BG than in RG. Furthermore, the combination of Rg3, Rg5, and Rk1, the major and most efficient components in BG, displayed 824% higher absorption (AUC24) in BG than in RG. The total ginsenoside showed a 5 h rapid intestinal absorption (Tmax) and 79% greater systemic exposure (AUC24) in BG than in RG. No clinically significant findings were observed in terms of safety or tolerability. Thus, BG extract was more effective than RG extract.

15 December 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MSMyeong-Bae Shin
Myeong-Bae Shin
SKSung-Ah Kim
Sung-Ah Kim
SLSooyoung Lee
Sooyoung Lee
WSWang Seob Shim
Wang Seob Shim
KLKyung-Tae Lee
Kyung-Tae Lee
BKBo-Hyung Kim
Bo-Hyung Kim
Fermentation of red ginseng (RG) produces fermented red ginseng (FRG), thereby increasing the relative amount of downstream ginsenosides, including compound Y (CY), F2, Rh2, compound K (CK), compound O, protopanaxadiol (PPD), and protopanaxatriol (PPT). These downstream ginsenosides have beneficial pharmacological effects, and are easily absorbed by the human body. Based on these expectations, a randomized, single-dose, two-period, crossover clinical trial was planned to compare the pharmacokinetic characteristics of seven types (Rb1, CY, F2, CK, Rh2, PPD, and PPT) of ginsenoside components after FRG and RG administration. The safety and tolerability profiles were assessed in this clinical trial. Sixteen healthy Korean male subjects were administered 6 g of FRG or RG. All ginsenosides except Rb1 showed higher systemic exposure after FRG administration than after RG administration, based on comparisons of ginsenoside Cmax and area under the concentration–time curve (AUC) between FRG and RG. CK, the main ginsenoside component produced during the fermentation process, had 69.23/74.53-fold higher Cmax/AUClast after administration of FRG than RG, and Rh2 had 20.27/18.47-fold higher Cmax/AUClast after administration of FRG than RG. In addition, CY and F2 were detected in FRG; however, all plasma concentrations of CY and F2, except in one subject, were below the lower limit of quantification in RG. There were no clinically significant findings with respect to clinical laboratory tests, blood pressures, or adverse events. Therefore, regular administration of FRG may exert better pharmacological effects than RG.

2 March 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
SCSanghee Choi
Sanghee Choi
WSWang Seob Shim
Wang Seob Shim
JYJiyoung Yoon
Jiyoung Yoon
DCDoowon Choi
Doowon Choi
JLJinseong Lee
Jinseong Lee
KLKyung-Tae Lee
Kyung-Tae Lee
The purpose of this study was to develop a method for simultaneously separating ibuprofen enantiomers using electrospray ionization (ESI) liquid chromatography with tandem mass spectrometry (LC–MS/MS). LC–MS/MS was operated with negative ionization and multiple reaction monitoring modes; transitions were monitored at m/z of 205.1 > 160.9 for ibuprofen enantiomers, 208.1 > 163.9 for (S)-(+)-ibuprofen-d3 [internal standard 1 (IS1)], and 253.1 > 208.9 for (S)-(+)-ketoprofen (IS2), respectively. In a one-step liquid–liquid extraction, 10 μL plasma was extracted with ethyl acetate:methyl tertiary-butyl ether of 7:3. Enantiomer chromatographic separation was carried out with an isocratic mobile phase consisting of 0.008% formic acid in water–methanol (v/v) at a flow rate of 0.4 mL/min on a CHIRALCEL® OJ-3R column (150 × 4.6 mm, 3 µm). This method was fully validated for each enantiomer and results were in compliance with the regulatory guidelines of the U.S. Food and Drug Administration and the Korea Ministry of Food and Drug Safety. The validated assay was executed for nonclinical pharmacokinetic studies after oral and intravenous administration of racemic ibuprofen and dexibuprofen in beagle dogs.

19 October 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
SLSuhyun Lee
Suhyun Lee
SYSeungwon Yang
Seungwon Yang
WSWang Seob Shim
Wang Seob Shim
ESEunseo Song
Eunseo Song
SHSeunghoon Han
Seunghoon Han
ECEun Kyoung Chung
Eun Kyoung Chung
Background/Objectives: This study aimed to develop a fully validated HPLC-MS/MS method for quantifying total and unbound lenalidomide concentrations in human plasma. Methods: Unbound concentrations were measured using plasma ultrafiltrate prepared with Amicon® Centrifugal Filters. Lenalidomide and lenalidomide-d5 (internal standard) were extracted from 50 μL of human plasma using liquid–liquid extraction. Chromatography was conducted with a Halo® C18 column using 0.1% formic acid and methanol (20:80, v/v) as the mobile phase. The mass spectrometer was operated in a positive ion mode with an electrospray ionization interface and multiple reaction monitoring modes. Results: Calibration curves were linear over the range of 5 to 1000 ng/mL (r2 > 0.996) for both the total and unbound lenalidomide. For total lenalidomide concentrations, between-run precision (coefficients of variation) and accuracy were 1.70–7.65% and 94.45–101.10%, respectively. For unbound concentrations, inter-day precision and accuracy were 1.98–10.55% and 93.95–98.48%, respectively. Conclusions: We developed a highly reproducible, sensitive, and efficient bioanalytical method using a smaller volume of plasma sample (50 μL) with a relatively short run time (2.5 min). The proposed analytical method was successfully applied to measure total and unbound lenalidomide concentrations at various time points in multiple myeloma patients with renal impairment.

19 November 2021 in Molecules
Verified
Journal Article
Open access
PDF file
SLSooyoung Lee
Sooyoung Lee
WSWang Seob Shim
Wang Seob Shim
HYHeejo Yoo
Heejo Yoo
SCSanghee Choi
Sanghee Choi
JYJiyoung Yoon
Jiyoung Yoon
KLKyung-Tae Lee
Kyung-Tae Lee
A sensitive and reproducible liquid chromatography-tandem mass spectrometry (LC-MS/MS) system was developed and fully validated for the simultaneous determination of ephedrine and pseudoephedrine in human plasma after oral administration of the herbal prescription Ojeok-san (OJS); 2-phenylethylamine was used as the internal standard (IS). Both compounds presented a linear calibration curve (r2 ≥ 0.99) over a concentration range of 0.2–50 ng/mL. The developed method was fully validated in terms of selectivity, lower limit of quantitation, precision, accuracy, recovery, matrix effect, and stability, according to the regulatory guidelines from the U.S. Food and Drug Administration and the Korea Ministry of Food and Drug Safety. This validated method was successfully applied for the pharmacokinetic assessment of ephedrine and pseudoephedrine in 20 healthy Korean volunteers administered OJS.

3 March 2023 in Molecules
Verified
Journal Article
Open access
PDF file
JYJiyoung Yoon
Jiyoung Yoon
DCDoowon Choi
Doowon Choi
WSWang Seob Shim
Wang Seob Shim
SCSanghee Choi
Sanghee Choi
YCYeo Jin Choi
Yeo Jin Choi
KLKyung-Tae Lee
Kyung-Tae Lee
This study aimed to establish a simple and sensitive analytical method to simultaneously quantify donepezil (DPZ) and tadalafil (TAD) in rat plasma using lansoprazole (LPZ) as an internal standard (IS) by using liquid chromatography tandem mass spectrometry. The fragmentation pattern of DPZ, TAD, and IS was elucidated using multiple reaction monitoring in electrospray ionization positive ion mode for the quantification of precursor to production at m/z 380.1 → 91.2 for DPZ, m/z 390.2 → 268.1 for TAD, and m/z 370.3 → 252.0 for LPZ. The extracted DPZ and TAD from plasma using acetonitrile-induced protein precipitation was separated using Kinetex C18 (100 × 2.1 mm, 2.6 µm) column with a gradient mobile phase system consisting of 2 mM ammonium acetate and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min for 4 min. The selectivity, lower limit of quantification, linearity, precision, accuracy, stability, recovery, and matrix effect of this developed method was validated according to the guidelines of the U.S. Food and Drug Administration and the Ministry of Food and Drug Safety of Korea. The established method achieved acceptance criteria in all validation parameters, ensuring reliability, reproducibility, and accuracy, and was successfully implemented in a pharmacokinetic study on the co-administration of DPZ and TAD orally in rats.