Dena P. Garner

Dr. Dena P. Garner

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Ramsha ShamsRamsha Shams
Ramsha Shams
Kelsey DrasitesKelsey Drasites
Kelsey Drasites
VZVandana Zaman
Vandana Zaman
DMDenise Matzelle
Denise Matzelle
DSDonald C. Shields
Donald C. Shields
NBNaren L. Banik
Naren L. Banik
Spinal cord injury (SCI) affects approximately 300,000 people in the United States. Most individuals who sustain severe SCI also develop subsequent osteoporosis. However, beyond immobilization-related lack of long bone loading, multiple mechanisms of SCI-related bone density loss are incompletely understood. Recent findings suggest neuronal impairment and disability may lead to an upregulation of receptor activator of nuclear factor-κB ligand (RANKL), which promotes bone resorption. Disruption of Wnt signaling and dysregulation of RANKL may also contribute to the pathogenesis of SCI-related osteoporosis. Estrogenic effects may protect bones from resorption by decreasing the upregulation of RANKL. This review will discuss the current proposed physiological and cellular mechanisms explaining osteoporosis associated with SCI. In addition, we will discuss emerging pharmacological and physiological treatment strategies, including the promising effects of estrogen on cellular protection.

12 December 2017 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
NTNancey Trevanian Tsai
Nancey Trevanian Tsai
JGJesse S. Goodwin
Jesse S. Goodwin
MSMark E. Semler
Mark E. Semler
RKRonald T. Kothera
Ronald T. Kothera
MHMark Van Horn
Mark Van Horn
DGDena P. Garner
Dena P. Garner
Qualitative assessments of the blink reflex are used clinically to assess neurological status in critical care, operating room, and rehabilitative settings. Despite decades of literature supporting the use of quantitative measurements of the blink reflex in the evaluation of multiple neurological disorders, clinical adoption has failed. Thus, there remains an unmet clinical need for an objective, portable, non-invasive metric of neurological health that can be used in a variety of settings. We have developed a high-speed videography-based device to trigger, record, and analyze a blink reflex. A pilot study was performed to compare the device’s measurements to the published literature of electromyographic measurements, currently the gold standard. The study results indicate that the device is a viable tool to obtain fast, objective, and quantitative metrics of a blink reflex, and has promise as a non-invasive diagnostic assessment of neurological health.

1 January 2018 in Cogent Engineering
Verified
Journal Article
Open access
DGDena P. Garner
Dena P. Garner
JGJ.S. Goodwin
J.S. Goodwin
NTN.T. Tsai
N.T. Tsai
RKR.T. Kothera
R.T. Kothera
MSM.E. Semler
M.E. Semler
BWB.J. Wolf
B.J. Wolf
The Centers for Disease Control and Prevention estimates 1.6–3.8 million concussions occur each year. Research cites that 21% of traumatic brain injury in children/youth results from participation in sports and recreational activities. However, current methods to assess concussion, which includes balance, neurocognitive, and self-report assessments, provide conflicting validity and reliability. Thus, many sports medicine professionals seek more objective measures to assess the severity and outcomes of a concussive event. The purpose of this study was to utilize a novel technology to determine if there were differences in blink reflex parameters among baseline, active, and concussed athletes. Twenty-four Division I football athletes participated in this study. Routine pre-season baseline data were collected on athletes as well as assessments of their blink reflex parameters using a blink reflexometer. Significant differences were found in blink parameters between baseline and active measurements in latency, differential latency, lid velocity, log of time to open, log of number of oscillations, and log of total blink time. In addition, significant differences were found between baseline and post-head impact in latency, differential latency, log of time to open, and log of number of oscillations. In comparing head impact and active play, blink latency decreased with head impact but increased in active play and differential latency and log of number of oscillations increased with head impact but decreased in active play. The results of this study suggest that use of a blink reflexometer provides quantifiable and objective outcomes to complement the concussion assessment protocol for athletes.

2 December 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
Kelsey DrasitesKelsey Drasites
Kelsey Drasites
Ramsha ShamsRamsha Shams
Ramsha Shams
VZVandana Zaman
Vandana Zaman
DMDenise Matzelle
Denise Matzelle
DSDonald C. Shields
Donald C. Shields
NBNaren L. Banik
Naren L. Banik
A spinal cord injury (SCI) may lead to loss of strength, sensation, locomotion and other body functions distal to the lesion site. Individuals with SCI also develop secondary conditions due to the lack of skeletal muscle activity. As SCI case numbers increase, recent studies have attempted to determine the best options to salvage affected musculature before it is lost. These approaches include pharmacotherapeutic options, immunosuppressants, physical activity or a combination thereof. Associated biomarkers are increasingly used to determine if these treatments aid in the protection and reconstruction of affected musculature.

6 January 2020 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
PDF file
DGDena P. Garner
Dena P. Garner
JLJensine Lamira
Jensine Lamira
Objective: Sleep apnea research cites that an oral appliance, which places the mandible in a more forward position and the genioglossus (tongue muscle) on the floor of the mouth, improves aspects of the pharyngeal opening. Exercise science research has cited improvements in airway dynamics and physiological variables with oral appliance use during exercise. Thus, the purpose of this study was to design an oral appliance that would act on the genioglossus and determine if there were effects on respiratory parameters while exercising.Materials and methods: Seventeen healthy subjects ages 18–43 participated in this study. Prior to the exercise protocol, the order of the oral applicance (OA) or no oral appliance (no OA) condition was randomly assigned to subjects, with subjects completing both conditions. Respiratory parameters (respiratory rate, ventilation, oxygen, and carbon dioxide) were measured between conditions while subjects ran for 10 min at steady state.Results: The results demonstrated that both respiratory rate (25.97 BPM, OA and 28.35 BPM, no OA) and ventilation (47.66 l/min, OA and 50.34 l/min, No OA) were significantly lowered (p < .01) in the OA condition. There were no differences in carbon dioxide (1.89 l/min, no OA and 1.88 l/min, OA) or oxygen outcomes (2.17 l/min, no OA and 2.17 l/min OA).Discussion: The outcomes from this study suggest that the design of the oral appliance elicits an effect on the genioglossus, thereby resulting in lowered respiratory rate and ventilation with no negative effects on oxygen uptake during exercise.

1 January 2017 in Cogent Medicine
Verified
Journal Article
Open access
WDW.D. Dudgeon
W.D. Dudgeon
LBL.A. Buchanan
L.A. Buchanan
ASA.E. Strickland
A.E. Strickland
TST.P. Scheett
T.P. Scheett
DGDena P. Garner
Dena P. Garner
Recent reports suggest the use of mouthpieces may be beneficial at improving aerobic and anaerobic exercise performance. However, the mechanisms of these reported improvements have yet to be elucidated. The purpose of this study was to explore the possible mechanisms of improved performance using the ArmourBite® mouthpiece. Using a within subject randomized treatment design, 15 experienced resistance trained males (19–26 years of age) performed 6 sets of 10 repetitions of free weight back squats at 80% of 1RM with and without a mouthpiece. Blood samples were collected before exercise, after 3 sets (Mid), immediately post (Post), 30 min post (Post-30), 60 min post (Post-60) and 120 min post (Post-120) exercise. Samples were analyzed for lactate and ELISA was used to determine cortisol. Mouthpiece use resulted in more repetitions completed without assistance (54.36 ± 0.61 vs. 53.27 ± 0.79, p = 0.046) and fewer assisted repetitions (6.73 ± 0.79 vs. 5.64 ± 0.61 repetitions, p = 0.046) compared to the control group. Lactate concentrations were lower in the treatment vs. control group at the Post (11.54 ± 2.23 vs. 13.07 ± 2.96 mmol/L, p = 0.023) Post- 30 (4.45 ± 1.94 vs. 5.41 ± 1.90 mmol/L, p = 0.021), and Post-60 (2.07 ± 0.94 vs. 2.55 ± 0.96 mmol/L, p = 0.048) sampling periods. Mouthpiece use lowered cortisol levels at Mid and Post-30 (19.39 ± 6.90 vs. 27.84 ± 14.56 μg/dL, p = 0.02 (22.91 ± 8.47 vs. 31.81 ± 10.79 μg/dL, p = 0.04). Cortisol AUC values showed significant differences within the AUC Pre-Post control and treatment (55.16 ± 23.84 vs. 41.95 ± 2.65 μg/dL, p = 0.02) groups. These data suggest that mouthpiece use may increase performance and decrease stress when used during intense resistance exercise.