Ying Chen

Dr. Ying Chen

Department of Materials and the Henry Royce Institute, the University of Manchester, Manchester M13 9PL, UK
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Acta Materialia
Verified
Journal Article
Closed access
Ying ChenYing Chen
Ying Chen
xiaofeng Zhaoxiaofeng Zhao
xiaofeng Zhao
PXPing Xiao
Ping Xiao

28 February 2011 in Biomedical Materials
Verified
Journal Article
Open access
PDF file
Ying ChenYing Chen
Ying Chen
YSYang Song
Yang Song
SZShaoxiang Zhang
Shaoxiang Zhang
JLJianan Li
Jianan Li
CZChangli Zhao
Changli Zhao
XZXiaonong Zhang
Xiaonong Zhang
In this study, polycaprolactone (PCL) and polylactic acid (PLA) coatings were prepared on the surface of high purity magnesium (HPMs), respectively, and electrochemical and dynamic degradation tests were used to investigate the degradation behaviors of these polymer-coated HPMs. The experimental results indicated that two uniform and smooth polymer films with thicknesses between 15 and 20 µm were successfully prepared on the HPMs. Electrochemical tests showed that both PCL-coated and PLA-coated HPMs had higher free corrosion potentials (Ecorr) and smaller corrosion currents (Icorr) in the modified simulated body fluid (m-SBF) at 37 °C, compared to those of the uncoated HPMs. Dynamic degradation tests simulating the flow conditions in coronary arteries were carried out on a specific test platform. The weight of the specimens and the pH over the tests were recorded to characterize the corrosion performance of those samples. The surfaces of the specimens after the dynamic degradation tests were also examined. The data implied that there was a special interaction between HPM and its polymer coatings during the dynamic degradation tests, which undermined the corrosion resistance of the coated HPMs. A model was proposed to illustrate the interaction between the polymer coatings and HPM. This study also suggested that this reciprocity may also exist on the implanted magnesium stents coated with biodegradable polymers, which is a potential obstacle for the further development of drug-eluting magnesium stents.

1 April 2020 in Corrosion Science
Verified
Journal Article
Closed access
JLJie Lu
Jie Lu
Ying ChenYing Chen
Ying Chen
HZHan Zhang
Han Zhang
NNNa Ni
Na Ni
LLLing Li
Ling Li
FGFangwei Guo
Fangwei Guo

1 June 2019 in Corrosion Science
Verified
Journal Article
Closed access
JLJie Lu
Jie Lu
Ying ChenYing Chen
Ying Chen
CZChunshan Zhao
Chunshan Zhao
HZHan Zhang
Han Zhang
LLLirong Luo
Lirong Luo
PXPing Xiao
Ping Xiao

1 July 2020 in Corrosion Science
Verified
Journal Article
Closed access
JLJie Lu
Jie Lu
Ying ChenYing Chen
Ying Chen
HZHan Zhang
Han Zhang
LLLing Li
Ling Li
LFLiming Fu
Liming Fu
PXPing Xiao
Ping Xiao

1 April 2017 in Acta Materialia
Verified
Journal Article
Closed access
Ying ChenYing Chen
Ying Chen
xiaofeng Zhaoxiaofeng Zhao
xiaofeng Zhao
Mingwen BaiMingwen Bai
Mingwen Bai
LYL. Yang
L. Yang
CLC. Li
C. Li
PXP. Xiao
P. Xiao