A label-free, low-photodamage, low-cost, and in vivo high-resolution microscopic imaging technique has been challenging to develop. Ghost imaging (GI) is a computational imaging protocol with the spatially nonlocal property, which enables low-light imaging. Considering the advantages of GI, we propose a method, called high-resolution microscopic ghost imaging (HRMGI), to achieve high-resolution imaging by simply demagnifying the signal beam. The analytical formulas for resolution and depth of field (DOF) of HRMGI are provided. Experimental results show that the HRMGI system can have 10.5 times higher resolution than the conventional GI, which can exceed the pixel size limit of multipixel detectors, and 58 times greater DOF than the traditional diffraction-limited optical (TDLO) system. To present the performance of HRMGI, blood vessels within an ovarian section are also imaged. The proposed method is expected to facilitate the development of bioimaging techniques and promote the practical application of GI.
Typical single-pixel imaging techniques for edge detection are mostly based on first-order differential edge detection operators. In this paper, we present a novel edge detection scheme combining Fourier single-pixel imaging with a second-order Laplacian of Gaussian (LoG) operator. This method utilizes the convolution results of an LoG operator and Fourier basis patterns as the modulated patterns to extract the edge detail of an unknown object without imaging it. The simulation and experimental results demonstrate that our scheme can ensure finer edge detail, especially under a noisy environment, and save half the processing time when compared with a traditional first-order Sobel operator.
The array spatial light field is an effective means for improving imaging speed in single-pixel imaging. However, distinguishing the intensity values of each sub-light field in the array spatial light field requires the help of the array detector or the time-consuming deep-learning algorithm. Aiming at this problem, we propose measurable speckle gradation Hadamard single-pixel imaging (MSG-HSI), which makes most of the refresh mechanism of the device generate the Hadamard speckle patterns and the high sampling rate of the bucket detector and is capable of measuring the light intensity fluctuation of the array spatial light field only by a simple bucket detector. The numerical and experimental results indicate that data acquisition in MSG-HSI is 4 times faster than in traditional Hadamard single-pixel imaging. Moreover, imaging quality in MSG-HSI can be further improved by image stitching technology. Our approach may open a new perspective for single-pixel imaging to improve imaging speed.