Department of Orthopaedics and Traumatology, Department of Dentistry and Oral Health, Division of Oral Surgery and Orthodontics, Medical University of Graz, Billrothgasse 4, 8010 Graz, Austria
Dr. Valentin Herber
Department of Orthopaedics and Traumatology, Department of Dentistry and Oral Health, Division of Oral Surgery and Orthodontics, Medical University of Graz, Billrothgasse 4, 8010 Graz, Austria
Bone preservation and primary regeneration is a daily challenge in the field of dental medicine. In recent years, bioresorbable metals based on magnesium (Mg) have been widely investigated due to their bone-like modulus of elasticity, their high biocompatibility, antimicrobial, and osteoconductive properties. Synthetic Mg-based biomaterials are promising candidates for bone regeneration in comparison with other currently available pure synthetic materials. Different alloys based on Mg were developed to fit clinical requirements. In parallel, advances in additive manufacturing offer the possibility to fabricate experimentally bioresorbable metallic porous scaffolds. This review describes the promising clinical results of resorbable Mg-based biomaterials for bone repair in osteosynthetic application and discusses the perspectives of use in oral bone regeneration.
Background: 3D printing is a rapidly developing technology in the healthcare industry and in dentistry. Its application clearly shows that this area of digital dentistry has potential for everyday usage across all fields, including prosthodontics, orthodontics, maxillofacial surgery, and oral implantology. However, despite gaining ground, there is a lack of information about how specialists (dentists and dental technicians) use additive technology. Our research group aimed to investigate the impact of social media on additive manufacturing technology among dental specialists and their everyday usage of 3D printing. Methods: This paper investigated specialists’ everyday usage of 3D printers via an online survey (Google Forms). The survey questions aimed to discover the number of 3D printers used, the accessibility of the devices, the annual cost, and the design programs. Since specialists tend to build online communities on social media, we circulated our study questionnaire using our profiles on LinkedIn, Facebook, and Instagram platforms during our research. Results: A total of 120 responses were received from 20 countries, with the most significant numbers being from Hungary 23.7% (n = 27), the United States 18.4% (n = 21), and the United Kingdom 7.9% (n = 9). Most of the participants were dentists (n = 68) or dental technicians (n = 29), but some CAD/CAM specialists (n = 23) also completed our survey. The participants had an average of 3.8 years (±0.7) of experience in the 3D printing field, and owned a total of 405 printing devices (3.6 on average/person). Conclusions: The impact of social media on this research field is growing increasingly. Hence, we support specialists in joining virtual communities on professional platforms. This article intended to provide a practical overview, feedback, and direction for dentists interested in 3D printing technology. From our survey, we can conclude that additive technology is broadening dental applications and the services that we can provide for our patients.
Aims: This study is a prospective, non-randomized trial for the treatment of fractures of the medial malleolus using lean, bioabsorbable, rare-earth element (REE)-free, magnesium (Mg)-based biodegradable screws in the adult skeleton. Methods: A total of 20 patients with isolated, bimalleolar, or trimalleolar ankle fractures were recruited between July 2018 and October 2019. Fracture reduction was achieved through bioabsorbable Mg-based screws composed of pure Mg alloyed with zinc (Zn) and calcium (Ca) ( Mg-Zn0.45-Ca0.45, in wt.%; ZX00). Visual analogue scale (VAS) and the presence of complications (adverse events) during follow-up (12 weeks) were used to evaluate the clinical outcomes. The functional outcomes were analyzed through the range of motion (ROM) of the ankle joint and the American Orthopaedic Foot and Ankle Society (AOFAS) score. Fracture reduction and gas formation were assessed using several plane radiographs. Results: The follow-up was performed after at least 12 weeks. The mean difference in ROM of the talocrural joint between the treated and the non-treated sites decreased from 39° (SD 12°) after two weeks to 8° (SD 11°) after 12 weeks (p ≤ 0.05). After 12 weeks, the mean AOFAS score was 92.5 points (SD 4.1). Blood analysis revealed that Mg and Ca were within a physiologically normal range. All ankle fractures were reduced and stabilized sufficiently by two Mg screws. A complete consolidation of all fractures was achieved. No loosening or breakage of screws was observed. Conclusion: This first prospective clinical investigation of fracture reduction and fixation using lean, bioabsorbable, REE-free ZX00 screws showed excellent clinical and functional outcomes. Cite this article: Bone Joint Res 2020;9(8):477–483.
Implant removal is unnecessary for biodegradable magnesium (Mg)-based implants and, therefore, the related risk for implant-induced fractures is limited. Aging, on the other hand, is associated with low bone-turnover and decreased bone mass and density, and thus increased fracture risk. Osteoporosis is accompanied by Mg deficiency, therefore, we hypothesized that Mg-based implants may support bone formation by Mg2+ ion release in an ovariectomy-induced osteoporotic rat model. Hence, we investigated osseointegration and implant degradation of a low-alloyed, degrading Mg-Zn-Ca implant (ZX00) in ovariectomy-induced osteoporotic (Osteo), old healthy (OH), and juvenile healthy (JH) groups of female Sprague Dawley rats via in vivo micro-computed tomography (µCT). For the Osteo rats, we demonstrate diminished trabecular bone already after 8 weeks upon ovariectomy and significantly enhanced implant volume loss, with correspondingly pronounced gas formation, compared to the OH and JH groups. Sclerotic rim development was observed in about half of the osteoporotic rats, suggesting a prevention from foreign-body and osteonecrosis development. Synchrotron radiation-based µCT confirmed lower bone volume fractions in the Osteo group compared to the OH and JH groups. Qualitative histological analysis additionally visualized the enhanced implant degradation in the Osteo group. To date, ZX00 provides an interesting implant material for young and older healthy patients, but it may not be of advantage in pharmacologically untreated osteoporotic conditions. STATEMENT OF SIGNIFICANCE: Magnesium-based implants are promising candidates for treatment of osteoporotic fractures because of their biodegradable, biomechanical, anti-bacterial and bone regenerative properties. Here we investigate magnesium‒zinc‒calcium implant materials in a rat model with ovariectomy-induced osteoporosis (Osteo group) and compare the related osseointegration and implant degradation with the results obtained for old healthy (OH) and juvenile healthy (JH) rats. The work applied an appropriate disease model for osteoporosis and focused in particular on long-term implant degradation for different bone conditions. Enhanced implant degradation and sclerotic rim formation was observed in osteoporotic rats, which illustrates that the setting of different bone models generates significantly modified clinical outcome. It further illustrated that these differences must be taken into account in future biodegradable implant development.
Ankle is the most common site of hardware removal, mainly performed within 12 months of the primary surgery. The prominence of the metallic hardware is a frequent cause of pain after fracture fixation. Over the last decade, the development of bioresorbable materials based on magnesium (Mg) has increased. Bioresorbable metals aim to avoid a second surgery for hardware removal. Twenty patients with isolated, bimalleolar, or trimalleolar ankle fractures were treated with bioresorbable screws made of Mg, 0.45wt% calcium (Ca) and 0.45wt% zinc (Zn) (ZX00). Patient-reported outcome measures (PROMs) including visual analogue scale (VAS) for pain, the presence of complications 6 and 12 months after surgery and the AOFAS scale after 12 months were reported. The functional outcomes were analysed through the range of motion (ROM) of the ankle joint with a standard goniometer. Degradation products and the bioresorbability of the screws were evaluated using plane radiographs. One patient was lost to follow-up. All patients were free of pain, no complications, shoe conflict or misalignement were reported after 12 months of follow-up. No Mg screws were surgically removed. An additional fixation of the distal fibula or the dorsal tibial fragment with conventional titanium implants (Ti) was performed in 17 patients. Within 12 months after primary refixation, 12 of these patients (71%) underwent a second surgery for Ti hardware removal. The mean AOFAS score was 89.8±7.1 and the difference between the treated and the non-treated site in the ROM of the talocrural joint was 2°±11° after 12 months. Radiolucent areas around the screws were attributed to degradation and did not affect clinical or functional outcomes. After one year, the Mg screw heads could not be detected in the plane radiographs of 17 patients which suggests that the majority of the screw head is degraded without introducing adverse reactions. At 6 and 12 months, the bioresorbable Mg screws show excellent PROMs without complications or need for screw removal. The resorbability of the screw heads in most of the patients after one year could also provide an advantage over conventional bio-inert implants by avoiding related skin irritation due for instance to shoe conflict.
22 December 2022 in Transfusion Medicine and Hemotherapy
Background: The application of blood concentrates has gained popularity in dentistry in recent years. Platelet-rich fibrin (PRF) has been discussed frequently due to a high content of growth factors and the option of chair-side manufacturing in a simple centrifugation process. PRF is free from adjuvants and inexpensive to produce. The number of studies reporting beneficial effects of PRF in various clinical applications such as alveolar ridge preservation, sinus floor elevation, management and prevention of medical-related osteonecrosis of the jaw, third molar extractions, and guided bone regeneration in dentistry has increased recently. However, to date, neither clinical recommendations nor guidelines are available. The present narrative review aims to summarize the level of evidence on the clinical application of PRF within the field of oral surgery and implantology. Summary: A literature search in Pubmed and Medline has identified 34 articles as a basis for this narrative review. The effectiveness of the clinical application of PRF has been analyzed for five indications within dentistry: medical-related osteonecrosis of the jaw, wisdom tooth extraction, guided bone regeneration, sinus floor elevation, and alveolar ridge preservation. The amount of data for third molar extractions, socket preservation, and guided bone regeneration is extensive. Less data were available for the use of PRF in combination with sinus floor elevations. There is a lack of studies with scientific evidence on PRF and medical-related osteonecrosis of the jaw; however, studies positively impact patient-related outcome measures. Most studies report on beneficial effects when PRF is additionally applied in intrabony defects. There is no evidence of the positive effects of PRF combined with bone graft materials during sinus floor elevation. However, some benefits are reported with PRF as a sole filling material. Key Messages: Many recently published studies show the positive clinical impact of PRF. Yet, further research is needed to ensure the validity of the evidence.