The current evidence on the clinical implementation of iterative reconstruction into CT protocols shows substantial promise for major improvements in image quality, chiefly noise reduction—with subsequent radiation dose reduction—and artifact suppression. Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limi...
In early stages of various pulmonary diseases, such as emphysema and fibrosis, the change in X-ray attenuation is not detectable with absorption-based radiography. To monitor the morphological changes that the alveoli network undergoes in the progression of these diseases, we propose using the dark-field signal, which is related to small-angle scattering in the sample. Combined with the absorption-based image, the dark-field signal enables better discrimination between healthy and emphysematous lung tissue in a mouse model. All measurements have been performed at 36 keV using a monochromatic laser-driven miniature synchrotron X-ray source (Compact Light Source). In this paper we present grating-based dark-field images of emphysematous vs. healthy lung tissue, where the strong dependence of the dark-field signal on mean alveolar size leads to improved diagnosis of emphysema in lung radiographs.
The aim of this study was to determine whether texture features of rectal cancer on T2-weighted (T2w) magnetic resonance images can predict tumoral response in patients treated with neoadjuvant chemoradiotherapy (CRT). We prospectively enrolled 15 consecutive patients (6 women, 63.2 ± 13.4 years) with rectal cancer, who underwent pretreatment and midtreatment 3-T magnetic resonance imaging. Treatment protocol consisted of neoadjuvant CRT with oxaliplatin and 5-fluorouracile. Texture analysis using a filtration-histogram technique was performed using a commercial research software algorithm (TexRAD Ltd, Somerset, England, United Kingdom) on unenhanced axial T2w images by manually delineating a region of interest around the tumor outline for the largest cross-sectional area. The technique selectively filters and extracts textures at different anatomic scales followed by quantification of the histogram using kurtosis, entropy, skewness, and mean value of positive pixels. After CRT, all patients underwent complete surgical resection and the surgical specimen served as the gold standard. Six patients showed pathological complete response (pCR), and 4 patients, partial response (PR). Five patients were classified as nonresponders (NRs). Pretreatment medium texture-scale quantified as kurtosis was significantly lower in the pCR subgroup in comparison with the PR + NR subgroup (P = 0.01). Midtreatment kurtosis without filtration was significantly higher in pCR in comparison with PR + NR (P = 0.045). The change in kurtosis between midtreatment and pretreatment images was significantly lower in the PR + NR subgroup compared with the pCR subgroup (P = 0.038). Pretreatment area under the receiver operating characteristic curves, to discriminate between pCR and PR + NR, was significantly higher for kurtosis (0.907, P < 0.001) compared with all other parameters. The optimal cutoff value for pretreatment kurtosis was 0.19 or less. Using this value, the sensitivity and specificity for pCR prediction were 100% and 77.8%, respectively. Texture parameters derived from T2w images of rectal cancer have the potential to act as imaging biomarkers of tumoral response to neoadjuvant CRT.
Objectives Energetic extrapolation is a promising strategy to reduce metal artifacts in dual-source computed tomography (DSCT). We performed this study to systematically optimize image acquisition parameters for this approach in a hip phantom and assess its value in a clinical study. Materials and Methods Titanium and steel hip prostheses were placed in a standard hip phantom and a water tank and scanned on a DSCT scanner. Tube spectra, tube current ratio, collimation, pitch, and rotation time were optimized in a stepwise process. Artifacts were quantified by measuring the standard deviation of the computed tomography density in a doughnut-shaped region of interest placed around the prosthesis. A total of 22 adult individuals with metallic implants referred for computed tomography for a musculoskeletal indication were scanned using the optimized protocol. Degree of artifacts and diagnostic image quality were rated visually (0–10) and maximum streak intensity was measured. Results Sn140/100 kVp proved superior to Sn140/80 kVp. There was a benefit for increasing tube current ratio from 1:1 to 3:1, but not beyond, in favor of the Sn140 kVp spectrum. Artifacts were less severe for a collimation of 32 × 0.6 mm as compared with 40 × 0.6 mm. A pitch of 0.5 at a rotation time of 0.5 seconds per rotation was preferable to other combinations with comparable scanning times. In the clinical study, increasing the extrapolated photon energy from 64 to 120 keV decreased the severity of artifacts from 8.0 to 2.0 (P < 0.001) and decreased streak intensity from 871 to 153 HU (P < 0.001). The median diagnostic image quality rating improved from 2.5 to 8.0 (P < 0.001). The median energy level visually perceived as optimal for diagnostic evaluation was 113 keV (range, 100–130 keV). Conclusions Sn140/100 kVp with a tube current ratio of 3:1, a collimation of 32 × 0.6 mm, and extrapolated energies of 105 to 120 keV are optimal parameters for a dedicated DSCT protocol that effectively reduces metal artifacts by energetic extrapolation. The protocol effectively reduces metal artifacts in all types of metal implants. The optimized reconstructions yielded relevant additional findings.