Jörn Grensemann

Dr. Jörn Grensemann

Department of Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, 20246 Hamburg, Germany
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2018 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
Jörn GrensemannJörn Grensemann
Jörn Grensemann
Routine use of cardiac output (CO) monitoring became available with the introduction of the pulmonary artery catheter into clinical practice. Since then, several systems have been developed that allow for a less-invasive CO monitoring. The so-called “non-calibrated pulse contour systems” (PCS) estimate CO based on pulse contour analysis of the arterial waveform, as determined by means of an arterial catheter without additional calibration. The transformation of the arterial waveform signal as a pressure measurement to a CO as a volume per time parameter requires a concise knowledge of the dynamic characteristics of the arterial vasculature. These characteristics cannot be measured non-invasively and must be estimated. Of the four commercially available systems, three use internal databases or nomograms based on patients’ demographic parameters and one uses a complex calculation to derive the necessary parameters from small oscillations of the arterial waveform that change with altered arterial dynamic characteristics. The operator must ensure that the arterial waveform is neither over- nor under-dampened. A fast-flush test of the catheter–transducer system allows for the evaluation of the dynamic response characteristics of the system and its dampening characteristics. Limitations to PCS must be acknowledged, i.e., in intra-aortic balloon-pump therapy or in states of low- or high-systemic vascular resistance where the accuracy is limited. Nevertheless, it has been shown that a perioperative algorithm-based use of PCS may reduce complications. When considering the method of operation and the limitations, the PCS are a helpful component in the armamentarium of the critical care physician.

8 June 2022 in Neurocritical Care
Verified
Journal Article
Open access
PDF file
Jörn GrensemannJörn Grensemann
Jörn Grensemann
MMMarius Marc-Daniel Mader
Marius Marc-Daniel Mader
MWManfred Westphal
Manfred Westphal
SKStefan Kluge
Stefan Kluge
PCPatrick Czorlich
Patrick Czorlich
Background: Adequate oxygenation in patients with aneurysmal subarachnoid hemorrhage (SAH) is imperative. However, hyperoxia increases formation of reactive oxygen species and may be associated with a dose-dependent toxicity. We postulated a threshold for arterial partial pressure of oxygen (paO2) above which toxicity effects precipitate and sought to study the effects on 30-day mortality, favorable outcome at discharge and at 3 months, and delayed cerebral ischemia. Methods: In this retrospective single-center cohort study, patients with SAH and mechanical ventilation > 72 h were included. Oxygen integrals were calculated above the following thresholds: 80, 100, 120, and 150 mm Hg and time-weighted mean paO2. All calculations were done from admission to end of day 1, day 3, and day 14. We conducted multivariable logistic regression analyses adjusted for age, sex, duration of ventilation, and Hunt and Hess grade. Time-weighted mean paO2 was categorized by quartiles. Favorable outcome was defined as Glasgow Outcome Scale scores of 4 and 5. Results: From November 2010 to February 2021, 282 of 549 patients fulfilled the inclusion criteria. Odds ratios for 30-day mortality increased dose dependently and were as follows: 1.07 (95% confidence interval [CI] 1.03–1.11; p = 0.001) for each 1 mm Hg per day above 80 mm Hg; 1.16 (95% CI 1.07–1.27), above 100 mm Hg; 1.36 (95% CI 1.15–1.61), above 120 mm Hg; and 1.59 (95% CI 1.22–2.08), above 150 mm Hg (all p < 0.001) at day 14. For favorable outcome at 3 months, odds ratios were 0.96 (95% CI 0.92–0.99) for each 1 mm Hg per day above 80 mm Hg; 0.90 (95% CI 0.84–0.98), above 100 mm Hg; 0.83 (95% CI 0.72–0.97), above 120 mm Hg; and 0.77 (95% CI 0.61–0.97), above 150 mm Hg (all p < 0.05). For time-weighted mean paO2, lowest 30-day mortality and highest favorable outcome at 3 months were found in the second quartile (78–85 mm Hg). Thirty-day mortality increased above 93 mm Hg (fourth quartile), with an odds ratio of 3.4 (95% CI 1.4–8.4, p = 0.007). Odds ratios for favorable outcome at 3 months were 0.28 (95% CI 0.12–0.69), 0.27 (95% CI 0.11–0.67), and 0.24 (95% CI 0.10–0.59) for the first, third, and fourth quartiles, respectively (all p < 0.01). No significant association was found at day 1 and day 3, for favorable outcome at discharge, or for delayed cerebral ischemia. Conclusions: Integrals above the defined paO2 thresholds were dose-dependently associated with an increase in mortality in ventilated patients with SAH. When we considered time-weighted mean paO2, unfavorable outcomes and 30-day mortality were more frequent both below and above a certain range. Unfavorable outcomes increased in paO2 ranges usually defined as normoxia. This emphasizes the necessity to further characterize oxygenation thresholds in ventilated patients with SAH in prospective clinical studies.

1 January 2020 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
Jörn GrensemannJörn Grensemann
Jörn Grensemann
DBDavid Busse
David Busse
CKChristina König
Christina König
KRKevin Roedl
Kevin Roedl
WJWalter Jäger
Walter Jäger
VFValentin Fuhrmann
Valentin Fuhrmann
Infection and sepsis are a main cause of acute-on-chronic liver failure (ACLF). Adequate dosing of antimicrobial therapy is of central importance to improve outcome. Liver failure may alter antibiotic drug concentrations via changes of drug distribution and elimination. We studied the pharmacokinetics of meropenem in critically ill patients with ACLF during continuous veno-venous hemodialysis (CVVHD) and compared it to critically ill patients without concomitant liver failure (NLF). In this prospective cohort study, patients received meropenem 1 g tid short-term infusion (SI). Meropenem serum samples were analyzed by high-performance liquid chromatography. A population pharmacokinetic analysis was performed followed by Monte Carlo simulations of (A) meropenem 1 g tid SI, (B) 2 g loading plus 1 g prolonged infusion tid (C) 2 g tid SI, and (D) 2 g loading and continuous infusion of 3 g/day on days 1 and 7. Probability of target attainment (PTA) was assessed for 4× the epidemiological cut-off values for Enterobacterales (4 × 0.25 mg/L) and Pseudomonas spp. (4 × 2 mg/L). Nineteen patients were included in this study. Of these, 8 patients suffered from ACLF. A two-compartment model with linear clearance from the central compartment described meropenem pharmacokinetics. The peripheral volume of distribution (V2) was significantly higher in ACLF compared to NLF (38.6L versus 19.7L, p = .05). PTA for Enterobacterales was achieved in 100% for all dosing regimens. PTA for Pseudomonas spp. in ACLF on day 1/7 was: A: 18%/80%, B: 94%/88%, C: 85%/98% D: 100%/100% and NLF: A: 48%/65%, B: 91%/83%, C: 91%/93%, D: 100%/100%. ALCF patients receiving CVVHD had a higher V2 and may require a higher loading dose of meropenem. For Pseudomonas, high doses or continuous infusion are required to reach PTA in ACLF patients.

21 September 2018 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
MMMarius Marc-Daniel Mader
Marius Marc-Daniel Mader
PCPatrick Czorlich
Patrick Czorlich
CKChristina König
Christina König
VFValentin Fuhrmann
Valentin Fuhrmann
SKStefan Kluge
Stefan Kluge
Jörn GrensemannJörn Grensemann
Jörn Grensemann

9 July 2018 in Deutsches Ärzteblatt international
Verified
Journal Article
Open access
Jörn GrensemannJörn Grensemann
Jörn Grensemann
VFValentin Fuhrmann
Valentin Fuhrmann
SKStefan Kluge
Stefan Kluge
Oxygen treatment is often life-saving, but multiple studies in recent years have yielded evidence that the indiscriminate administration of oxygen to patients in the intensive care unit and emergency room can cause hyperoxia and thereby elevate mortality. This review is based on prospective, randomized trials concerning the optimum use of oxygen in adult medicine, which were retrieved by a selective search in PubMed, as well as on pertinent retrospective studies and guideline recommendations. 13 prospective, randomized trials involving a total of 17 213 patients were analyzed. In patients with acute exacerbations of chronic obstructive pulmonary disease (COPD) and in ventilated intensive-care patients, normoxia was associated with a lower mortality than hyperoxia (2% vs. 9%). In patients with myocardial infarction, restrictive oxygen administration was associated with a smaller infarct size on cardiac MRI at 6 months compared to oxygen administration at 8 L/min (13.1 g vs. 20.3 g). For patients with stroke, the currently available data do not reveal any benefit or harm from oxygen administration. None of the trials showed any benefit from the administration of oxygen to non-hypoxemic patients; in fact, this was generally associated with increased morbidity or mortality. Hypoxemia should certainly be avoided, but the fact that the liberal administration of oxygen to patients in intensive care units and emergency rooms tends to increase morbidity and mortality implies the advisability of a conservative, normoxic oxygenation strategy.

29 December 2017 in Critical Care
Verified
Journal Article
Open access
PDF file
Jörn GrensemannJörn Grensemann
Jörn Grensemann
LELars Eichler
Lars Eichler
SKSophie Kähler
Sophie Kähler
DJDominik Jarczak
Dominik Jarczak
MSMarcel Simon
Marcel Simon
SKStefan Kluge
Stefan Kluge
Percutaneous dilatational tracheostomy (PDT) in critically ill patients often involves bronchoscopic optical guidance. However, this procedure is not without disadvantages. Therefore, we aimed to study a recently introduced endotracheal tube-mounted camera (VivaSightTM-SL tube [VST]; ETView, Misgav, Israel) for guiding PDT. This was a randomized controlled trial involving 46 critically ill patients who received PDT using optical guidance with a VST or with bronchoscopy. The primary outcome measure was visualization of the tracheal structures (i.e., identification and monitoring of the thyroid, cricoid, and tracheal cartilage and the posterior wall) rated on 4-point Likert scales. Secondary measures were the quality of ventilation (before puncture and during the tracheostomy procedure rated on 4-point Likert scales) and blood gases sampled at standardized time points. The mean ratings for visualization (lower values better; values given for per-protocol analysis) were 5.4 (95% CI 4.5–6.3) for the VST group and 4.0 (95% CI 4.0–4.0) for the bronchoscopy group (p < 0.001). Mean ventilation ratings were 2.5 (95% CI 2.1–2.9) for VST and 5.0 (95% CI 4.4–5.7) for bronchoscopy (p < 0.001). Arterial carbon dioxide increased to 5.9 (95% CI 5.4–6.5) kPa in the VST group vs. 8.3 (95% CI 7.2–9.5) kPa in the bronchoscopy group (p < 0.001), and pH decreased to 7.40 (95% CI 7.36–7.43) in the VST group vs. 7.26 (95% CI 7.22–7.30) in the bronchoscopy group (p < 0.001), at the end of the intervention. Visualization of PDT with the VST is not noninferior to guidance by bronchoscopy. Ventilation is superior with less hypercarbia with the VST. Because visualization is not a prerequisite for PDT, patients requiring stable ventilation with normocarbia may benefit from PDT with the VST. ClinicalTrials.gov, NCT02861001 . Registered on 13 June 2016.