Cristina Peris-Martínez

Prof. Dr. Cristina Peris-Martínez

FUNDACION DE OFTALMOLOGIA MÉDICA-FOM, Valencia, Spain
+1
orcid
Medical Director

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
EAEmma Arnal
Emma Arnal
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
JMJose Luis Menezo
Jose Luis Menezo
SJSiv Johnsen-Soriano
Siv Johnsen-Soriano
FRFrancisco J. Romero
Francisco J. Romero
Purpose.: The purpose of this study was to establish the alterations of oxidative stress-related markers in keratoconus (KC) corneas. Methods.: A total of 6 healthy and 11 ectatic corneas (7 KC and 4 post-LASIK) were studied. Different oxidative stress-related markers were determined to assess their implication in the KC pathophysiology. Total antioxidant capacity and total nitrites present in the samples were assayed. Furthermore, lipid peroxidation products and the glutathione contents were determined, together with 4-hydroxynonenal (4-HNE) immunohistochemistry, to establish the relationship between KC and oxidative stress. Results.: The antioxidant capacity and glutathione content in KC corneas were decreased significantly when compared with healthy corneas. Moreover, the total nitrites and lipid peroxidation were significantly elevated in the corneas with KC when compared with the controls. There was a statistically significant difference in the amount of HNE-positive cells in KC corneas when compared with healthy corneas by immunohistochemistry. Post-LASIK ectatic corneas and KC corneas showed similar results. Conclusions.: The increased levels of oxidative stress markers and the decreased antioxidant capacity and antioxidant defenses in KC corneas, as well as in the post-LASIK ectatic corneas, indicate that oxidative stress might be involved in the development of this disease and may provide new insights for its prevention and treatment in the future.

1 December 2007 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
JAJosé M. Artigas
José M. Artigas
JMJosé L. Menezo
José L. Menezo
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
AFAdelina Felipe
Adelina Felipe
MDManuel Díaz-Llopis
Manuel Díaz-Llopis
To analyze the image quality with a refractive and 2 hybrid refractive-diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Fundación Oftalmológica del Mediterráneo, Valencia, Spain. This study evaluated 4 IOLs: the hybrid refractive-diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd.) using fast Fourier transform techniques. The artificial eye model simulated in vivo conditions of the anterior chamber and included an artificial cornea and physiological solution, in which the IOLs were positioned. The pupil sizes varied between 2.0 mm and 5.0 mm in steps of 0.5 mm. For distance vision and small pupils (2.0 to 3.5 mm), the refractive IOL provided better image quality than the 2 hybrid IOLs. When the pupil was larger, the distance vision was similar with all IOLs. The 2 hybrid IOLs gave better image quality than the refractive IOL for near vision with any pupil size. With the refractive IOL and pupils smaller than 3.5 mm, near focusing did not occur, resulting in poor image quality. Of the hybrid IOLs, the AcrySof ReSTOR SN60D3 provided better distance image quality and the Tecnis ZM900 provided better near image quality. The refractive IOL gave better image quality than the hybrid IOLs at distance and with small pupils. With pupils larger than 3.5 mm, the quality was similar. Hybrid IOLs gave significantly better image quality for near vision with all pupil sizes. AcrySof ReSTOR SN60D3 IOLs give better distance vision than Tecnis ZM900 IOLs; the latter gave better near vision. The reference monofocal IOL provided better distance images than any multifocal IOL with all pupil sizes.

1 January 2004 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
JMJosé L Menezo
José L Menezo
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
ACAngel L Cisneros
Angel L Cisneros
RMRafael Martínez-Costa
Rafael Martínez-Costa
To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. La Fe University Hospital, Department of Ophthalmology, and the Fundación Oftalmológica del Mediterráneo, Valencia, Spain. In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was -15.39 diopters (D) +/- 2.83 (SD), -16.00 +/- 5.05 D, and -16.17 +/- 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The mean follow-up was 32.4 months (range 19 to 46 months) in the Adatomed group, 18.3 months (range 11 to 21 months) in the Staar group, and 121.4 months (range 38.4 to 154.3 months) in the Artisan group. At the follow-up examinations, intraocular pressure (IOP), IOL pigment deposits, cataract formation, and visual acuity were evaluated. The best corrected and uncorrected visual acuities improved in all eyes. No significant differences in visual acuity improvement were observed with the 3 materials, although the improvement was somewhat greater in eyes with the Artisan and Staar IOLs. The difference in mean IOP between preoperatively and the last follow-up examination was 1.5 mm Hg in the Staar group, 1.3 mm Hg in the Adatomed group, and 1.7 mm Hg in the Artisan group (P =.36, P =.26, and P =.32, respectively). The incidence of pigment deposits was similar in the Adatomed and Staar groups, with deposits in 32 eyes (54.23%) and 8 eyes (38.1%), respectively. Anterior cataract formation was higher in the Adatomed group (44.06%) than in the Staar group (9.52%); nuclear cataract developed in 2 Adatomed eyes (1.46%) only. There was a higher incidence of anterior subcapsular cataract formation in the Adatomed group than in the Staar group. Delayed cataract development and the cataract type in patients with Artisan IOLs indicate that age and axial length may be prognostic factors. Factors such as IOL design, material, and placement probably affect cataract formation in eyes with posterior chamber IOLs for high myopia, particularly the Adatomed IOL.

28 May 2021 in Foods
Verified
Journal Article
Open access
PDF file
MVMar Valero-Velló
Mar Valero-Velló
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
Jose Javier Garcia-MedinaJose Javier Garcia-Medina
Jose Javier Garcia-Medina
SGSilvia María Sanz González
Silvia María Sanz González
Ana I. RamírezAna I. Ramírez
Ana I. Ramírez
MPMaria Dolores Pinazo-Duran
Maria Dolores Pinazo-Duran
Adherence to a healthy diet offers a valuable intervention to compete against the increasing cases of ocular diseases worldwide, such as dry eye disorders, myopia progression, cataracts, glaucoma, diabetic retinopathy, or age macular degeneration. Certain amounts of micronutrients must be daily provided for proper functioning of the visual system, such as vitamins, carotenoids, trace metals and omega-3 fatty acids. Among natural foods, the following have to be considered for boosting eye/vision health: fish, meat, eggs, nuts, legumes, citrus fruits, nuts, leafy green vegetables, orange-colored fruits/vegetables, olives-olive oil, and dairy products. Nutritional supplements have received much attention as potential tools for managing chronic-degenerative ocular diseases. A systematic search of PubMed, Web of Science, hand-searched publications and historical archives were performed by the professionals involved in this study, to include peer-reviewed articles in which natural food, nutrient content, and its potential relationship with ocular health. Five ophthalmologists and two researchers collected the characteristics, quality and suitability of the above studies. Finally, 177 publications from 1983 to 2021 were enclosed, mainly related to natural food, Mediterranean diet (MedDiet) and nutraceutic supplementation. For the first time, original studies with broccoli and tigernut (chufa de Valencia) regarding the ocular surface dysfunction, macular degeneration, diabetic retinopathy and glaucoma were enclosed. These can add value to the diet, counteract nutritional defects, and help in the early stages, as well as in the course of ophthalmic pathologies. The main purpose of this review, enclosed in the Special Issue “Health Benefits and Nutritional Quality of Fruits, Nuts and Vegetables,” is to identify directions for further research on the role of diet and nutrition in the eyes and vision, and the potential antioxidant, anti-inflammatory and neuroprotective effects of natural food (broccoli, saffron, tigernuts and walnuts), the Mediterranean Diet, and nutraceutic supplements that may supply a promising and highly affordable scenario for patients at risk of vision loss. This review work was designed and carried out by a multidisciplinary group involved in ophthalmology and ophthalmic research and especially in nutritional ophthalmology.

16 March 2020 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
PDF file
ASAbhay Shah
Abhay Shah
WCWarren Clarida
Warren Clarida
RARyan Amelon
Ryan Amelon
MHMaria C. Hernaez-Ortega
Maria C. Hernaez-Ortega
ANAmparo Navea
Amparo Navea
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
Purpose: The purpose of this study is to compare the diagnostic performance of an autonomous artificial intelligence (AI) system for the diagnosis of referable diabetic retinopathy (RDR) to manual grading by Spanish ophthalmologists. Methods: Subjects with type 1 and 2 diabetes participated in a diabetic retinopathy (DR) screening program in 2011 to 2012 in Valencia (Spain), and two images per eye were collected according to their standard protocol. Mydriatic drops were used in all patients. Retinal images—one disc and one fovea centered—were obtained under the Medical Research Ethics Committee approval and de-identified. Exams were graded by the autonomous AI system (IDx-DR, Coralville, Iowa, United States), and manually by masked ophthalmologists using adjudication. The outputs of the AI system and manual adjudicated grading were compared using sensitivity and specificity for diagnosis of both RDR and vision-threatening diabetic retinopathy (VTDR). Results: A total of 2680 subjects were included in the study. According to manual grading, prevalence of RDR was 111/2680 (4.14%) and of VTDR was 69/2680 (2.57%). Against manual grading, the AI system had a 100% (95% confidence interval [CI]: 97%-100%) sensitivity and 81.82% (95% CI: 80%-83%) specificity for RDR, and a 100% (95% CI: 95%-100%) sensitivity and 94.64% (95% CI: 94%-95%) specificity for VTDR. Conclusion: Compared to manual grading by ophthalmologists, the autonomous diagnostic AI system had high sensitivity (100%) and specificity (82%) for diagnosing RDR and macular edema in people with diabetes in a screening program. Because of its immediate, point of care diagnosis, autonomous diagnostic AI has the potential to increase the accessibility of RDR screening in primary care settings.

14 May 2020 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
SMSalvador Mérida
Salvador Mérida
VVVincent M. Villar
Vincent M. Villar
ANAmparo Navea
Amparo Navea
CDCARMEN DESCO
CARMEN DESCO
MSMaría Sancho-Tello
María Sancho-Tello
FBFrancisco Bosch-Morell
Francisco Bosch-Morell
Myopia is one of the commonest eye pathologies that could affect 2.56 billion people by 2020. Today high myopia is a leading cause of blindness worldwide due to associated ocular illness. Nevertheless, the cellular bases for these diseases to develop are unclear in many areas. We conducted a prospective study of oxidative stress and growth factors in human myopic and non myopic eyes in an attempt to increase our understanding of the underlying physiopathological conditions to adequately early diagnose, prevent and treat the retina problem that derives from myopia. Aqueous humor samples were obtained from 41 patients being operated for cataracts in our hospital. Axial length, refractive status and complete ophthalmologic examination were recorded. The VEGF and HGF levels were determined by an ELISA kit. Total antioxidant capacity and total nitrites/nitrate levels were established with a lab kit. We show for the first time an increase in the total nitrite levels in high myopia. We also propose for the first time the concurrence of three factors: myopia, oxidative stress, and oxidative stress together with growth factors in the same group of patients. In this way, it would not be accurate to envision high myopia as a type of normal myopia, but one with more diopters or longer axial length.